Home › Engine / Hybrid System › 2GR-FE ENGINE CONTROL › HEATED OXYGEN SENSOR
RM2030EQ _51 Engine / Hybrid System _014634 2GR-FE ENGINE CONTROL _0074407 HEATED OXYGEN SENSOR G

2GR-FE ENGINE CONTROL  HEATED OXYGEN SENSOR  INSPECTION  


PROCEDURE

Hide 89465 1.INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)

a.
A256126
1.396,1.302 1.01,1.188 false 1.875,1.281 2.198,1.167 false 1.396,1.708 1,1.854 false 0.115,0.115 0.292,0.281 0.177,0.167 10 *a 0.771,1.094 0.969,1.25 0.198,0.156 10 +B 2.26,1.083 2.656,1.24 0.396,0.156 10 HT1B 0.792,1.792 1,1.948 0.208,0.156 10 E2
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
1 (HT1B) - 4 (E2) - 10 kΩ or higher


If the resistance is not as specified, replace the heated oxygen sensor.


Hide 89465 2.INSPECT HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)

a.
A192463
1.385,1.292 0.875,1.115 false 1.896,1.281 2.458,1.146 false 1.385,1.677 0.844,1.76 false 0.115,0.104 0.323,0.292 0.208,0.188 10 *a 2.521,1.052 2.917,1.344 0.396,0.292 10 HT2B 0.646,1.01 0.875,1.271 0.229,0.26 10 +B 0.635,1.698 0.865,2 0.229,0.302 10 E2
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (HT2B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
1 (HT2B) - 4 (E2) - 10 kΩ or higher


If the resistance is not as specified, replace the heated oxygen sensor.