Home › Engine / Hybrid System › 2GR-FE ENGINE CONTROL › INTEGRATION RELAY
RM2030EQ _51 Engine / Hybrid System _014634 2GR-FE ENGINE CONTROL _0074408 INTEGRATION RELAY G

2GR-FE ENGINE CONTROL  INTEGRATION RELAY  INSPECTION  


PROCEDURE

Hide 82641 1.INSPECT NO. 1 INTEGRATION RELAY

A276670
0.823,2.271 1.063,2.469 0.24,0.198 10 false 1A 0.885,2.073 1.042,2.271 0.156,0.198 10 false 8 6.177,0.76 6.417,0.958 0.24,0.198 10 false 1C 6.198,0.563 6.354,0.76 0.156,0.198 10 false 4 6.177,1.083 6.375,1.281 0.198,0.198 10 false 1C 6.198,0.917 6.354,1.115 0.156,0.198 10 false 3 6.177,1.552 6.396,1.75 0.219,0.198 10 false 1C 6.156,1.885 6.354,2.083 0.198,0.198 10 false 1C 6.198,1.365 6.354,1.563 0.156,0.198 10 false 9 6.177,1.708 6.354,1.906 0.177,0.198 10 false 10 6.167,2.281 6.406,2.479 0.24,0.198 10 false 1B 6.177,2.615 6.406,2.813 0.229,0.198 10 false 1C 6.198,2.104 6.302,2.302 0.104,0.198 10 false 1 6.198,2.438 6.302,2.635 0.104,0.198 10 false 7 6.198,3.333 6.302,3.531 0.104,0.198 10 false 1 6.177,3.531 6.396,3.729 0.219,0.198 10 false 1D 6.156,4.865 6.375,5.063 0.219,0.198 10 false 1C 6.198,4.698 6.354,4.896 0.156,0.198 10 false 6 6.177,5.531 6.406,5.729 0.229,0.198 10 false 1D 6.219,5.344 6.375,5.542 0.156,0.198 10 false 3 6.177,5.875 6.417,6.073 0.24,0.198 10 false 1C 6.219,5.688 6.375,5.885 0.156,0.198 10 false 8 6.177,4.333 6.406,4.531 0.229,0.198 10 false 1E 6.219,4.146 6.375,4.344 0.156,0.198 10 false 2 6.177,6.542 6.406,6.74 0.229,0.198 10 false 1C 6.177,6.875 6.385,7.073 0.208,0.198 10 false 1C 6.177,7.219 6.417,7.375 0.24,0.156 10 false 1C 6.219,6.385 6.375,6.583 0.156,0.198 10 false 5 6.219,6.698 6.375,6.896 0.156,0.198 10 false 2 6.219,7.031 6.375,7.229 0.156,0.198 10 false 1 4.042,2.875 4.719,3.135 0.677,0.26 10 false EFI MAIN 4.031,4.135 4.656,4.396 0.625,0.26 10 false A/F HTR 4.229,6.094 4.531,6.354 0.302,0.26 10 false IG2 2.469,2.406 3.146,2.667 0.677,0.26 10 false EFI NO. 3 3.333,1.677 4.01,1.938 0.677,0.26 10 false EFI NO. 2 1.75,5.667 2.094,5.927 0.344,0.26 10 false IGN 1.76,6.052 2.031,6.313 0.271,0.26 10 false INJ 1.417,6.677 2.469,6.938 1.052,0.26 10 false ECU-IG2 NO. 3 0.823,3.542 1.177,3.74 0.354,0.198 10 false 1A 0.823,3.865 1.177,4.063 0.354,0.198 10 false 1A 0.823,5.531 1.031,5.729 0.208,0.198 10 false 1A 0.823,5.906 1.042,6.104 0.219,0.198 10 false 1A 0.854,3.354 1.01,3.552 0.156,0.198 10 false 7 0.854,3.698 1.01,3.896 0.156,0.198 10 false 6 0.865,5.333 1.021,5.531 0.156,0.198 10 false 1 0.823,5.021 1.031,5.219 0.208,0.198 10 false 1A 0.865,4.823 1.021,5.021 0.156,0.198 10 false 2 0.865,5.729 1.021,5.927 0.156,0.198 10 false 3 0.823,6.552 1.052,6.75 0.229,0.198 10 false 1A 0.885,6.375 1.042,6.573 0.156,0.198 10 false 5 0.823,2.594 1.115,2.792 0.292,0.198 10 false 1A 0.875,2.417 1.031,2.615 0.156,0.198 10 false 4 0.104,0.063 0.26,0.26 0.156,0.198 10 false *1 1.583,5.448 1.698,5.625 0.115,0.177 10 false 2 2.042,5.448 2.156,5.625 0.115,0.177 10 false 1 3.823,1.458 3.938,1.635 0.115,0.177 10 false 2 3.375,1.448 3.49,1.625 0.115,0.177 10 false 1 2.469,2.167 2.583,2.344 0.115,0.177 10 false 2 2.927,2.167 3.042,2.344 0.115,0.177 10 false 1 1.583,6.458 1.698,6.635 0.115,0.177 10 false 2 2.042,6.458 2.156,6.635 0.115,0.177 10 false 1 1.583,5.802 1.698,5.979 0.115,0.177 10 false 2 2.042,5.802 2.156,5.979 0.115,0.177 10 false 1
*1 No. 1 Integration Relay - -


a.

EFI MAIN Relay:

i.
A255141
1.052,0.5 1.542,0.792 0.49,0.292 0.74,2.229 1.229,2.521 0.49,0.292 1.313,2.229 1.802,2.521 0.49,0.292 1.906,2.229 2.396,2.521 0.49,0.292 2.438,2.229 2.927,2.521 0.49,0.292 1.198,0.573 1.385,0.833 0.188,0.26 10 1A 0.875,2.302 1.063,2.563 0.188,0.26 10 1B 1.427,2.292 1.667,2.552 0.24,0.26 10 1C 2.052,2.302 2.302,2.563 0.25,0.26 10 1D 2.583,2.302 2.771,2.563 0.188,0.26 10 1E 0.083,0.083 0.271,0.344 0.188,0.26 10 *1
*1 No. 1 Integration Relay


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
No. 1 integration relay 1B-1 - No. 1 integration relay 1A-8 Battery voltage is not applied between terminals 1C-7 and 1E-2 10 kΩ or higher
No. 1 integration relay 1B-1 - No. 1 integration relay 1A-8 Battery voltage is applied between terminals 1C-7 and 1E-2 Below 1 Ω
No. 1 integration relay 1B-1 - No. 1 integration relay 1C-3
No. 1 integration relay 1B-1 - No. 1 integration relay 1C-4
No. 1 integration relay 1B-1 - No. 1 integration relay 1C-9
No. 1 integration relay 1B-1 - No. 1 integration relay 1C-10


If the resistance is not as specified, replace the No. 1 integration relay.



b.

A/F HTR Relay:

i.
A255141
1.052,0.5 1.542,0.792 0.49,0.292 0.74,2.229 1.229,2.521 0.49,0.292 1.313,2.229 1.802,2.521 0.49,0.292 1.906,2.229 2.396,2.521 0.49,0.292 2.438,2.229 2.927,2.521 0.49,0.292 1.188,0.573 1.375,0.833 0.188,0.26 10 1A 0.885,2.313 1.073,2.573 0.188,0.26 10 1B 1.458,2.313 1.698,2.573 0.24,0.26 10 1C 2.052,2.313 2.302,2.573 0.25,0.26 10 1D 2.583,2.313 2.771,2.573 0.188,0.26 10 1E 0.094,0.104 0.365,0.354 0.271,0.25 10 *1
*1 No. 1 Integration Relay


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
No. 1 integration relay 1A-6 - No. 1 integration relay 1D-1 Battery voltage is not applied between terminals 1A-8 and 1E-2 10 kΩ or higher
No. 1 integration relay 1A-6 - No. 1 integration relay 1D-1 Battery voltage is applied between terminals 1A-8 and 1E-2 Below 1 Ω
No. 1 integration relay 1A-7 - No. 1 integration relay 1D-1


If the resistance is not as specified, replace the No. 1 integration relay.



c.

IG2 Relay:

i.
A255141
1.052,0.5 1.542,0.792 0.49,0.292 0.74,2.229 1.229,2.521 0.49,0.292 1.313,2.229 1.802,2.521 0.49,0.292 1.906,2.229 2.396,2.521 0.49,0.292 2.438,2.229 2.927,2.521 0.49,0.292 1.198,0.583 1.594,0.833 0.396,0.25 10 1A 0.885,2.313 1.156,2.594 0.271,0.281 10 1B 1.469,2.313 1.708,2.573 0.24,0.26 10 1C 2.063,2.313 2.313,2.573 0.25,0.26 10 1D 2.583,2.313 2.948,2.615 0.365,0.302 10 1E 0.094,0.125 0.406,0.385 0.313,0.26 10 *1
*1 No. 1 Integration Relay


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
No. 1 integration relay 1A-1 - No. 1 integration relay 1D-3 Battery voltage is not applied between terminals 1C-8 and 1E-2 10 kΩ or higher
No. 1 integration relay 1A-1 - No. 1 integration relay 1D-3 Battery voltage is applied between terminals 1C-8 and 1E-2 Below 1 Ω
No. 1 integration relay 1A-3 - No. 1 integration relay 1D-3
No. 1 integration relay 1A-5 - No. 1 integration relay 1D-3
No. 1 integration relay 1C-1 - No. 1 integration relay 1D-3
No. 1 integration relay 1C-2 - No. 1 integration relay 1D-3
No. 1 integration relay 1C-5 - No. 1 integration relay 1D-3


If the resistance is not as specified, replace the No. 1 integration relay.