Home › Engine / Hybrid System › 2GR-FE EMISSION CONTROL › PURGE VALVE
RM2030EQ _51 Engine / Hybrid System _014637 2GR-FE EMISSION CONTROL _0074428 PURGE VALVE G

2GR-FE EMISSION CONTROL  PURGE VALVE  INSPECTION  


PROCEDURE

Hide 25860A 1.INSPECT PURGE VSV

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω


If the result is not as specified, replace the purge VSV.


b.
A192096
1.156,1.167 0.792,1.167 false 1.865,1.313 1.542,1.677 1.542,1.677 1.354,1.677 false 2.885,1.552 3.135,1.75 0.25,0.198 10 false *c 0.625,1.083 0.885,1.292 0.26,0.208 10 false *b 1.177,1.583 1.427,1.781 0.25,0.198 10 false *a
*a Port E
*b Port F
*c Air


Apply battery voltage between the terminals of the purge VSV and check that the following occurs when blowing air into port E.

OK:
Measurement Condition Specified Condition
Battery voltage applied between terminals 1 and 2 Air flows from port F
Battery voltage not applied between terminals 1 and 2 Air does not flow


If the result is not as specified, replace the purge VSV.