Hide 27415 1.INSPECT GENERATOR PULLEY WITH CLUTCH

a.
A240512
0.833,0.677 1,0.979 0.167,0.302 10 *a 2.51,0.708 2.677,1.01 0.167,0.302 10 *b
*a Free
*b Lock


Hold the generator rotor using SST, and turn the generator pulley with clutch clockwise to check that the outer ring locks.

SST
09820-63021  

If the result is not as specified, replace the generator pulley with clutch.


Hide 27310B 2.INSPECT GENERATOR DRIVE END FRAME BEARING

a.
A128080

Check that the bearing is not rough or worn.

OK:

The bearing rotates smoothly.


If the bearing does not rotate smoothly, replace the bearing.


Hide 27370 3.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A128079
0.604,0.635 1.021,0.833 0.417,0.198 10 *a
*a Length


Using a vernier caliper, measure the length of the exposed brushes.

Standard exposed brush length:

9.5 to 11.5 mm (0.375 to 0.452 in.)


Minimum exposed brush length:

4.5 mm (0.178 in.)


If the exposed brush length is less than the minimum, replace the generator brush holder assembly.


Hide 27330 4.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A079306
2.177,1.25 2.313,1.427 0.135,0.177 10 false .

Check that the generator rotor bearing is not rough or worn.

If necessary, replace the generator rotor assembly.


b.
A294038
0.354,1.135 0.698,0.25 0.698,0.25 0.448,1.083 true 0.635,0.094 0.948,0.25 0.313,0.156 10 false *1 2.344,0.156 2.656,0.313 0.313,0.156 10 false *2
*1 Slip Ring
*2 Ohmmeter


Check the generator rotor for an open circuit.

i.

Using an ohmmeter, measure the resistance between the slip rings.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring Approx. 20°C (68°F) 2.3 to 2.7 Ω


If the result is not as specified, replace the generator rotor assembly.



c.
A294039
0.396,1.146 0.771,1.573 false 1.281,0.802 1.604,0.583 false 0.792,1.542 1.104,1.698 0.313,0.156 10 false *1 1.656,0.458 1.969,0.615 0.313,0.156 10 false *2 2.344,0.125 2.656,0.281 0.313,0.156 10 false *3
*1 Slip Ring
*2 Rotor
*3 Ohmmeter


Check the rotor for a short to ground.

i.

Using an ohmmeter, measure the resistance between the slip ring and rotor.

Standard Resistance:
Tester Connection Specified Condition
Slip ring - Rotor 1 MΩ or higher


If the result is not as specified, replace the generator rotor assembly.



d.
A124106
0.667,0.406 0.844,0.552 0.177,0.146 10 *a
*a Diameter


Using a vernier caliper, measure the slip ring diameter.

Standard diameter:

14.2 to 14.4 mm (0.560 to 0.566 in.)


Minimum diameter:

14.0 mm (0.552 in.)


If the diameter is less than the minimum, replace the generator rotor assembly.