Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › SPIRAL CABLE › 2012.02–2015.04
RM2030EQ _58 Vehicle Interior _014669 SUPPLEMENTAL RESTRAINT SYSTEMS _0074622 SPIRAL CABLE G

SUPPLEMENTAL RESTRAINT SYSTEMS  SPIRAL CABLE  INSPECTION  


PROCEDURE

Hide 84306 1.INSPECT SPIRAL CABLE SUB-ASSEMBLY

NOTICE:
·

Do not remove the steering sensor from the spiral cable sub-assembly.

·

As the spiral cable sub-assembly may break, do not rotate the spiral cable sub-assembly more than the specified amount.



a.

Remove the spiral cable with sensor sub-assembly from the vehicle (See page Vehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>SPIRAL CABLE>REMOVAL).


b.

Visually check for defects with the spiral cable sub-assembly.

i.

The defects are as follows:

·

Scratches

·

Small cracks

·

Dents

·

Chips

·

Cracks or other damage to the connector

OK:

No defects are found.



If any of the defects is found, replace the spiral cable sub-assembly with a new one.



c.

Check the spiral cable sub-assembly.

C188036
5.51,0.208 5.781,0.385 0.271,0.177 6.094,0.208 6.365,0.385 0.271,0.177 2.573,0.427 2.844,0.604 0.271,0.177 1.01,1.323 1.281,1.5 0.271,0.177 1.625,1.229 1.896,1.406 0.271,0.177 5.583,0.219 5.969,0.552 0.385,0.333 10 z3 6.167,0.219 6.552,0.552 0.385,0.333 10 z2 2.646,0.427 3.031,0.76 0.385,0.333 10 z4 1.063,1.333 1.448,1.667 0.385,0.333 10 I27 1.677,1.24 2.063,1.573 0.385,0.333 10 I28 0.094,0.063 0.479,0.396 0.385,0.333 10 *a
*a Component without harness connected
(Spiral Cable Sub-assembly)
- -
V100144

Interlock - -


NOTICE:

When rotating the spiral cable, make sure to push on the interlock indicated in the illustration to release the interlock mechanism.


i.

Set the spiral cable sub-assembly to the center position (See page Vehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>SPIRAL CABLE>INSTALLATION).


ii.

Measure the resistance between each terminal of the spiral cable sub-assembly according to the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I28-1 (CCS) - z2-3 Always 3 Ω or less
I28-2 (ECC) - z2-4 Always 3 Ω or less
I28-2 (ECC) - z3-7 Always 3 Ω or less
I28-3 (EAU) - z3-8 Always 3 Ω or less
I28-4 (AU3) - z3-9 Always 3 Ω or less
I28-5 (AU2) - z3-10 Always 3 Ω or less
I28-6 (AU1) - z3-11 Always 3 Ω or less
I28-7 (SDN) - z3-12 Always 3 Ω or less
I28-9 (HO) - z3-1 Always 3 Ω or less
I28-10 (+DP) - z3-2 Always 3 Ω or less
I28-11 (-DP) - z3-3 Always 3 Ω or less
I28-13 (IL+2) - z3-5 Always 3 Ω or less
I28-14 (SUP) - z3-6 Always 3 Ω or less
I27-1 (D+) - z4-2 Always Below 1 Ω
I27-2 (D-) - z4-1 Always Below 1 Ω



iii.

After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise, and measure the resistance as shown in the table below. Then rotate the spiral cable sub-assembly 5 times counterclockwise, and measure the resistance as shown in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I28-1 (CCS) - z2-3 Always 3 Ω or less
I28-2 (ECC) - z2-4 Always 3 Ω or less
I28-2 (ECC) - z3-7 Always 3 Ω or less
I28-3 (EAU) - z3-8 Always 3 Ω or less
I28-4 (AU3) - z3-9 Always 3 Ω or less
I28-5 (AU2) - z3-10 Always 3 Ω or less
I28-6 (AU1) - z3-11 Always 3 Ω or less
I28-7 (SDN) - z3-12 Always 3 Ω or less
I28-9 (HO) - z3-1 Always 3 Ω or less
I28-10 (+DP) - z3-2 Always 3 Ω or less
I28-11 (-DP) - z3-3 Always 3 Ω or less
I28-13 (IL+2) - z3-5 Always 3 Ω or less
I28-14 (SUP) - z3-6 Always 3 Ω or less
I27-1 (D+) - z4-2 Always Below 1 Ω
I27-2 (D-) - z4-1 Always Below 1 Ω



iv.

After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise. Then while rotating the spiral cable sub-assembly 5 times counterclockwise, measure the resistance as shown in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I28-1 (CCS) - z2-3 Always 3 Ω or less
I28-2 (ECC) - z2-4 Always 3 Ω or less
I28-2 (ECC) - z3-7 Always 3 Ω or less
I28-3 (EAU) - z3-8 Always 3 Ω or less
I28-4 (AU3) - z3-9 Always 3 Ω or less
I28-5 (AU2) - z3-10 Always 3 Ω or less
I28-6 (AU1) - z3-11 Always 3 Ω or less
I28-7 (SDN) - z3-12 Always 3 Ω or less
I28-9 (HO) - z3-1 Always 3 Ω or less
I28-10 (+DP) - z3-2 Always 3 Ω or less
I28-11 (-DP) - z3-3 Always 3 Ω or less
I28-13 (IL+2) - z3-5 Always 3 Ω or less
I28-14 (SUP) - z3-6 Always 3 Ω or less
I27-1 (D+) - z4-2 Always Below 1 Ω
I27-2 (D-) - z4-1 Always Below 1 Ω


If the result is not as specified, replace the spiral cable with sensor sub-assembly.