Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM
RM2030EQ _59 Vehicle Exterior _014675 WINDOW / GLASS _0074675 POWER WINDOW CONTROL SYSTEM U

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM  FAIL-SAFE CHART  


POWER WINDOW OPERATION IN FAIL-SAFE MODE


HINT:

If the pulse sensor built into the power window regulator motor malfunctions, the power window control system enters fail-safe mode.


a.

The power window control system prohibits the following power window operations when the pulse sensor for the jam protection function has problems and the window position or the learned value is abnormal.

Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Ignition switch ON Ignition switch off
(Key-off operation permitted)
Ignition switch off
(Key-off operation prohibited)
Manual up (Driver door window) X X -
Manual down (Driver door window) ○ X -
Auto up (Driver door window)
(hold switch at auto up position)
○* X -
Auto up (Driver door window) X X -
Auto down (Driver door window) X X -

HINT:
·

○: Operates

·

X: Operation prohibited

·

*: Operates in manual mode without jam protection



Key-linked and Wireless Transmitter-linked Operation*1*2
Power Window Operation Condition
Ignition switch ON Ignition switch off
(Key-off operation permitted)
Ignition switch off
(Key-off operation prohibited)
Key-linked open and close - X X
Wireless transmitter-linked open - X X

*1: for RHD

*2: This function is set through the customize function, as it is off by default.


HINT:

X: Operation prohibited



i.

Power window regulator master switch LED control

HINT:

During normal operation (fail-safe is not operating), or during fail-safe mode when there is a pulse sensor malfunction or the window position or learned value is abnormal, the LED illuminates as shown in the illustration.


1.

For driver door:

B274523
4.625,0.823 5.198,0.198 5.198,0.198 5.354,0.198 false 0.719,1.667 1.375,2.042 0.656,0.375 10 Key-off operation: 1.885,2.146 2.573,2.323 0.688,0.177 10 Prohibited 1.896,1.688 2.531,1.865 0.635,0.177 10 Permitted 0.719,3.563 1.594,3.969 0.875,0.406 10 Window lock switch signal: 2.313,3.958 2.563,4.156 0.25,0.198 10 Off 2.313,3.594 2.573,3.833 0.26,0.24 10 On 0.75,2.688 1.125,2.906 0.375,0.219 10 LED: 1.948,3.115 2.563,3.333 0.615,0.219 10 Turns off 1.948,2.708 2.521,2.885 0.573,0.177 10 Turns on 0.729,0.688 1.677,0.896 0.948,0.208 10 Ignition switch: 2.292,1.177 2.531,1.354 0.24,0.177 10 Off 2.292,0.677 2.542,0.854 0.25,0.177 10 ON 5.427,0.125 6.833,0.333 1.406,0.208 10 Approximately 43 sec. 0.281,0.115 1.708,0.375 1.427,0.26 10 Normal output pattern:



ii.

Fail-safe deactivation condition

When the pulse sensor is normal, to deactivate fail-safe mode, pull up the power window switch to the auto up position and hold it for at least 1 second to fully close the window from the fully open position. As a result, the auto up/down function will return.




b.

Initialization failure

HINT:

During initialization of the power window regulator motor ECU, when the window position or initialization complete status cannot be properly read from the EEPROM, the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Ignition switch ON Ignition switch off
(Key-off operation permitted)
Ignition switch off
(Key-off operation prohibited)
Manual up (Driver door window) X X -
Manual down (Driver door window) ○ X -
Auto up (Driver door window)
(hold switch at auto up position)
○* X -
Auto up (Driver door window) X X -
Auto down (Driver door window) X X -

HINT:
·

○: Operates

·

X: Operation prohibited

·

*: Operates in manual mode without jam protection



Key-linked and Wireless Transmitter-linked Operation*1*2
Power Window Operation Condition
Ignition switch ON Ignition switch off
(Key-off operation permitted)
Ignition switch off
(Key-off operation prohibited)
Key-linked open and close - X X
Wireless transmitter-linked open - X X

*1: for RHD

*2: This function is set through the customize function, as it is off by default.


HINT:

X: Operation prohibited



i.

Power window regulator master switch LED control

HINT:

During initialization of the power window regulator motor ECU, when the window position or initialization complete status cannot be properly read from the EEPROM during fail-safe mode, the LED illuminates as shown in the illustration.


1.

For driver door:

B274524
4.042,3.573 3.958,3.573 3.958,3.573 3.76,3.104 false 0.719,3.531 1.615,3.917 0.896,0.385 10 Window lock switch signal: 2.25,3.948 2.479,4.135 0.229,0.188 10 Off 2.25,3.563 2.479,3.771 0.229,0.208 10 On 0.729,1.677 1.115,1.927 0.385,0.25 10 LED: 1.896,2.135 2.479,2.313 0.583,0.177 10 Turns off 1.875,1.677 2.49,1.885 0.615,0.208 10 Turns on 0.719,0.656 1.688,0.885 0.969,0.229 10 Ignition switch: 2.24,1.188 2.49,1.396 0.25,0.208 10 Off 2.219,0.656 2.469,0.875 0.25,0.219 10 ON 0.177,0.146 2.292,0.344 2.115,0.198 10 Initialization failure output pattern: 4.063,3.5 4.615,3.76 0.552,0.26 10 1.5 sec. 2.583,3.146 3.104,3.344 0.521,0.198 10 1.5 sec. 2.583,2.792 3.104,2.99 0.521,0.198 10 1.0 sec. 2.583,2.427 3.104,2.625 0.521,0.198 10 0.5 sec.




c.

LIN communication failure

HINT:

If the LIN communication line malfunctions (communication stop), the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Ignition switch ON
Manual up ○*
Manual down ○
Auto up (hold switch at auto up position) -
Auto up -
Auto down -

HINT:
·

○: Operates

·

*: Jam protection can operate.




d.

LIN communication failure and pulse sensor failure

HINT:

If the LIN communication line malfunctions (communication stop) and the pulse sensor for the jam protection function has problems, the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Always
Manual up X
Manual down X
Auto up (hold switch at auto up position) X
Auto up X
Auto down X

HINT:
·

X: Operation prohibited

·

When the jam protection function does not operate due to a LIN communication failure, the manual up and auto up functions will not operate.




e.

LIN communication failure and abnormal window position learned value or initialization failure

HINT:

If the LIN communication line malfunctions (communication stop) and the window position or the learned value is abnormal, the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Always
Manual up ○*
Manual down ○
Auto up (hold switch at auto up position) -
Auto up -
Auto down -

HINT:
·

○: Operates

·

*: Jam protection can operate and window reverses upon reaching the fully closed position.