Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW REGULATOR MOTOR(for Front Door)
RM2030EQ _59 Vehicle Exterior _014675 WINDOW / GLASS _0074679 POWER WINDOW REGULATOR MOTOR(for Front Door) G

WINDOW / GLASS  POWER WINDOW REGULATOR MOTOR(for Front Door)  INSPECTION  


PROCEDURE

Hide 85720D 1.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (w/ Jam Protection Function)

a.
B203475
1.198,2.531 1.198,2.208 1.198,2.208 1.594,2.208 false 1.083,2.521 1.073,2.208 1.073,2.208 0.531,2.208 false 1.219,2.698 1.219,3.031 1.219,3.031 1.448,3.031 false 1.052,2.698 1.052,3.021 1.052,3.021 0.615,3.021 false 0.135,0.083 0.542,0.406 0.406,0.323 10 false *a 1.656,2.135 1.854,2.344 0.198,0.208 10 false E 1.49,2.958 2.188,3.188 0.698,0.229 10 false DWN1 0.344,2.938 0.75,3.188 0.406,0.25 10 false UP1 0.406,2.125 0.615,2.354 0.208,0.229 10 false B 2.958,1.854 3.26,2.135 0.302,0.281 10 false *b 2.333,2.333 2.635,2.625 0.302,0.292 10 false *c
*a Component without harness connected
(Power Window Regulator Motor Assembly LH)
*b Counterclockwise
*c Clockwise


Apply positive (+) battery voltage to connector terminal 2 (B).

NOTICE:

Do not apply positive (+) battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.



b.

Connect a ground lead to connector terminals 1 (E) and 7 (DWN1) or 10 (UP1).


c.

Check that the motor gear rotates smoothly as follows:

OK:
Measurement Condition Specified Condition
1.

Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (E), and keep them connected for 3 seconds or more.

2.

With terminals 2 (B) and 1 (E) connected, connect a negative (-) battery lead to terminal 10 (UP1).

3.

Disconnect and reconnect the negative (-) battery lead for terminal 10 (UP1) within 1 second.


Motor gear rotates clockwise
1.

Connect the positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (E), and keep them connected for 3 seconds or more.

2.

With terminals 2 (B) and 1 (E) connected, connect a negative (-) battery lead to terminal 7 (DWN1).

3.

Disconnect and reconnect the negative (-) battery lead for terminal 7 (DWN1) within 1 second.


Motor gear rotates counterclockwise


If the result is not as specified, replace the power window regulator motor assembly LH.


NOTICE:

Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly onto the door.



Hide 85720D 2.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (w/o Jam Protection Function)

a.
B127535
0.115,0.115 0.281,0.292 0.167,0.177 10 false *a 1.583,0.948 1.76,1.156 0.177,0.208 10 false *c 1.25,1.646 1.406,1.844 0.156,0.198 10 false *d 0.729,0.292 0.896,0.469 0.167,0.177 10 false *b
*a Component without harness connected
(Power Window Regulator Motor Assembly LH)
*b Motor Gear
*c Counterclockwise
*d Clockwise


Apply battery voltage to the motor connector according to the table below.

NOTICE:

Do not apply battery voltage to any terminals except terminals 1 and 2.


Standard:
Measurement Condition Specified Condition
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Motor gear rotates clockwise
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Motor gear rotates counterclockwise


If the result is not as specified, replace the power window regulator motor assembly LH.


Hide 85710E 3.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH (w/ Jam Protection Function)

a.
B203474
2.406,2.5 2.406,2.188 2.406,2.188 2.833,2.188 false 2.271,2.5 2.271,2.188 2.271,2.188 1.781,2.188 false 2.25,2.677 2.25,2.969 2.25,2.969 1.802,2.969 false 2.427,2.677 2.427,2.979 2.427,2.979 2.667,2.979 false 0.063,0.063 0.417,0.375 0.354,0.313 10 false *a 2.698,2.896 3.24,3.177 0.542,0.281 10 false DWN1 2.854,2.104 3.115,2.375 0.26,0.271 10 false E 1.667,2.104 1.896,2.438 0.229,0.333 10 false B 1.5,2.885 1.969,3.24 0.469,0.354 10 false UP1 0.302,1.813 0.542,2.031 0.24,0.219 10 false *b 0.948,2.24 1.188,2.49 0.24,0.25 10 false *c
*a Component without harness connected
(Power Window Regulator Motor Assembly RH)
*b Clockwise
*c Counterclockwise


Apply positive (+) battery voltage to connector terminal 2 (B).

NOTICE:

Do not apply positive (+) battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.



b.

Connect a ground lead to connector terminals 1 (E) and 7 (DWN1) or 10 (UP1).


c.

Check that the motor gear rotates smoothly as follows:

OK:
Measurement Condition Specified Condition
1.

Connect the positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (E), and keep them connected for 3 seconds or more.

2.

With terminals 2 (B) and 1 (E) connected, connect a negative (-) battery lead to terminal 10 (UP1).

3.

Disconnect and reconnect the negative (-) battery lead for terminal 10 (UP1) within 1 second.


Motor gear rotates counterclockwise
1.

Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (E), and keep them connected for 3 seconds or more.

2.

With terminals 2 (B) and 1 (E) connected, connect a negative (-) battery lead to terminal 7 (DWN1).

3.

Disconnect and reconnect the negative (-) battery lead for terminal 7 (DWN1) within 1 second.


Motor gear rotates clockwise


If the result is not as specified, replace the power window regulator motor assembly RH.


NOTICE:

Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly onto the door.



Hide 85710E 4.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH (w/o Jam Protection Function)

a.
B127536
2.594,0.313 2.771,0.479 0.177,0.167 10 false *b 2.021,1.552 2.219,1.719 0.198,0.167 10 false *d 1.698,0.885 1.854,1.052 0.156,0.167 10 false *c 1.042,0.115 1.229,0.281 0.188,0.167 10 false *a
*a Component without harness connected
(Power Window Regulator Motor Assembly RH)
*b Motor Gear
*c Clockwise
*d Counterclockwise


Apply battery voltage to the motor connector according to the table below.

NOTICE:

Do not apply battery voltage to any terminals except terminals 1 and 2.


Standard:
Measurement Condition Specified Condition
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Motor gear rotates clockwise
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Motor gear rotates counterclockwise


If the result is not as specified, replace the power window regulator motor assembly RH.