When the ignition switch is turned to ON, voltage from the ECM's MREL terminal is applied to the EFI MAIN relay. This causes the contacts of the EFI MAIN relay to close, which supplies power to terminal +B of the TCM.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| *a | Front view of wire harness connector
(to TCM) |
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E7-8 (E1) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to TCM) |
Disconnect the TCM connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E7-18 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the NO. 1 integration relay from the engine room relay block and junction block assembly.
Disconnect the NO. 1 integration relay connector.
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E7-18 (+B) - 1A-4 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E7-18 (+B) or 1A-4 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG