Fail-safe


This function minimizes the loss of operation when any abnormality occurs in a sensor or solenoid.

Fail-safe Control List
Malfunction Part Function
Input Speed Sensor NT Shifting to only either 1st or 3rd gears is allowed.
Output Speed Sensor NC
·

The counter gear speed is determined based on the signals from the skid control ECU (speed sensor signals).

·

Shifting between 1st to 4th gears is allowed.


ATF Temp. Sensor Shifting between 1st to 4th gears is allowed.
ECT ECU
Power Supply (Voltage is Low)
When the vehicle is being driven in 6th gear, the transaxle is fixed in 6th gear. When being driven in any of 1st to 5th gears, the transaxle is fixed in 5th gear.
CAN communication Shifting to only either 1st or 3rd gears is allowed.
Knock Sensor Shifting between 1st to 4th gears is allowed.
Solenoid Valve SL1, SL2, SL3 and SL4 The current to the failed solenoid valve is cut off and operating the other solenoid valves with normal operation performs shift control. (Shift controls in fail-safe mode are described in the table on the next page. For details, refer to Fail-Safe Control Chart)

Solenoid Valve Operation when Normal
Gear 1st 2nd 3rd 4th 5th 6th
Solenoid SL1 ON ON ON ON OFF OFF
SL2 OFF OFF OFF ON ON ON
SL3 OFF ON OFF OFF OFF ON
SL4 OFF OFF ON OFF ON OFF

Fail-safe Control Chart
Gear in Normal Conditions 1st 2nd 3rd 4th 5th 6th
SL1 ON Malfunction (without Fail-safe Control)*1 1st 2nd 3rd 4th 4th 4th
OFF Malfunction (without Fail-safe Control) 1st to N 2nd to N 3rd to N 4th to N 5th 6th
Fail-safe Control during OFF Malfunction Fixed in 3rd or 5th
SL2 ON Malfunction (without Fail-safe Control)*1 1st to 4th 2nd to 4th 3rd to 4th 4th 5th 6th
OFF Malfunction (without Fail-safe Control) 1st 2nd 3rd 4th to 1st 5th to N 6th to N
Fail-safe Control during OFF Malfunction Fixed in 2nd or 3rd
SL3 ON Malfunction (without Fail-safe Control)*1 1st to 2nd 2nd 3rd 4th 5th 6th
OFF Malfunction (without Fail-safe Control) 1st 2nd to 1st 3rd 4th 5th 6th to N
Fail-safe Control during OFF Malfunction Fixed in 3rd
SL4 ON Malfunction (without Fail-safe Control)*1 3rd 3rd 3rd 4th 5th 5th
OFF Malfunction (without Fail-safe Control) 1st 2nd 3rd to 1st 4th 5th to N 6th
Fail-safe Control during OFF Malfunction Fixed in 2nd

*1: Fail-safe control is not actuated when an ON malfunction occurs.