The combination meter receives the turn signal switch information and controls the turn signal lights.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Combination Meter / Data List.
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Turn Signal Switch (Right) | Turn signal switch (Right) signal | ON or OFF | ON: Turn signal switch (Right) on
OFF: Turn signal switch (Right) off |
- |
| Turn Signal Switch (Left) | Turn signal switch (Left) signal | ON or OFF | ON: Turn signal switch (Left) on
OFF: Turn signal switch (Left) off |
- |
| Tester Display |
|---|
| Turn Signal Switch (Right) |
| Turn Signal Switch (Left) |
Normal conditions listed above are displayed.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the headlight dimmer switch assembly.
Click hereVehicle Exterior>LIGHTING (EXT)>HEADLIGHT DIMMER SWITCH>REMOVAL
for LHD:
| *a | Component without harness connected
(Headlight Dimmer Switch Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 12 (TR) - 15 (EL) | Turn signal switch in neutral position | 10 kΩ or higher |
| 11 (TL) - 15 (EL) | Turn signal switch in neutral position | 10 kΩ or higher |
| 12 (TR) - 15 (EL) | Turn signal switch in right turn position | Below 1 Ω |
| 11 (TL) - 15 (EL) | Turn signal switch in left turn position | Below 1 Ω |
for RHD:
| *a | Component without harness connected
(Headlight Dimmer Switch Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 20 (TR) - 16 (EL) | Turn signal switch in neutral position | 10 kΩ or higher |
| 19 (TL) - 16 (EL) | Turn signal switch in neutral position | 10 kΩ or higher |
| 20 (TR) - 16 (EL) | Turn signal switch in right turn position | Below 1 Ω |
| 19 (TL) - 16 (EL) | Turn signal switch in left turn position | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I17 combination meter assembly connector.
for LHD:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I25-12 (TR) - I17-9 (ER) | Always | Below 1 Ω |
| I25-11 (TL) - I17-10 (EL) | Always | Below 1 Ω |
| I25-15 (EL) - Body ground | Always | Below 1 Ω |
| I17-9 (ER) - Body ground | Always | 10 kΩ or higher |
| I17-10 (EL) - Body ground | Always | 10 kΩ or higher |
for RHD:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I25-20 (TR) - I17-9 (ER) | Always | Below 1 Ω |
| I25-19 (TL) - I17-10 (EL) | Always | Below 1 Ω |
| I25-16 (EL) - Body ground | Always | Below 1 Ω |
| I17-9 (ER) - Body ground | Always | 10 kΩ or higher |
| I17-10 (EL) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG