Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › BLIND SPOT MONITOR SYSTEM › from 2015.04
RM2030EQ _56 Audio / Visual / Telematics _014660 PARK ASSIST / MONITORING _0074560 BLIND SPOT MONITOR SYSTEM U

PARK ASSIST / MONITORING  BLIND SPOT MONITOR SYSTEM  TERMINALS OF ECU  


BLIND SPOT MONITOR SENSOR RH


E233761N27
2.302,0.75 2.677,0.979 0.375,0.229 2.375,0.771 2.906,1.125 0.531,0.354 10 false O32

Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Specified Condition
O32-4 (OMIR) - O32-10 (BRGD) G - BR Outer rear view mirror indicator power source signal RH Outer rear view mirror indicator RH illuminated 2.5 to 7.5 V
Outer rear view mirror indicator RH blinks Alternating between 0 to 7.5 V
Outer rear view mirror indicator RH not illuminated Below 1 V
O32-5 (BRB) - O32-10 (BRGD) L - BR IG power source signal Engine switch off Below 1 V
Engine switch on (IG) 11 to 14 V
O32-8 (BSSW) - O32-10 (BRGD) GR - BR Blind spot monitor main switch (warning canceling switch assembly) power source signal Engine switch on (IG), blind spot monitor main switch (warning canceling switch assembly) on 11 to 14 V
O32-8 (BSSW) - O32-10 (BRGD) Engine switch on (IG), blind spot monitor main switch (warning canceling switch assembly) off Below 1 V
O32-10 (BRGD) - Body Ground BR - Body ground Ground Always Below 1 V


BLIND SPOT MONITOR SENSOR LH


E233761N30
2.333,0.75 2.708,0.979 0.375,0.229 2.396,0.781 2.875,1.146 0.479,0.365 10 false T24

Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Specified Condition
T24-3 (BUZ) - T24-10(BLGD) B - BR RCTA buzzer (blind spot monitor buzzer) operation signal RCTA buzzer (blind spot monitor buzzer) not sounding 11 to 14 V
RCTA buzzer (blind spot monitor buzzer) sounding Alternating between 0 to 14 V
T24-4 (OMIL) - T24-10 (BLGD) G - BR Outer rear view mirror indicator power source signal LH Outer rear view mirror indicator LH illuminated 2.5 to 7.5 V
Outer rear view mirror indicator LH blinks Alternating between 0 to 7.5 V
Outer rear view mirror indicator LH not illuminated Below 1 V
T24-5 (BLB) - T24-10 (BLGD) L - BR IG power source signal Engine switch off Below 1 V
Engine switch on (IG) 11 to 14 V
T24-10 (BLGD) - Body Ground BR - Body ground Ground Always Below 1 V