Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › from 2016.05
RM2030EQ _58 Vehicle Interior _014672 HEATING / AIR CONDITIONING _0074651 AIR CONDITIONING SYSTEM U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Room temperature sensor (cooler thermistor) Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed -
Ambient Temp Sensor Ambient temperature sensor (thermistor assembly) Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed -
Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.8°C (123.44°F)
- -
Evaporator Fin Thermistor Evaporator temperature sensor (No. 1 cooler thermistor) Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed -
Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed -
Solar Sensor (D Side) Driver side automatic light control sensor (solar sensor) Min.: 0
Max.: 255
Driver side automatic light control sensor (solar sensor) value increases as brightness increases -
Solar Sensor (P Side) Front passenger side automatic light control sensor (solar sensor) Min.: 0
Max.: 255
Front passenger side automatic light control sensor (solar sensor) value increases as brightness increases -
Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed -
Set Temperature (D Side) Driver side set temperature Min.: MAX COLD
Max.: MAX HOT
Driver side set temperature displayed -
Set Temperature (P Side) Front passenger side set temperature Min.: MAX COLD
Max.: MAX HOT
Front passenger side set temperature displayed -
Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases -
Regulator Pressure Sensor Air conditioning pressure sensor Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual pressure displayed -
Regulator Control Current Solenoid valve control current Min.: 0 A
Max.: 0.997 A
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
Air Mix Servo Targ Pulse(D) for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (air mix*1) target pulse
for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (air mix*1) target pulse
Min.: 0
Max.: 255
for LHD:
MAX. COLD: 5 (pulse)
MAX. HOT: 103 (pulse)
for RHD:
MAX. COLD: 105
MAX. HOT: 7
-
Air Mix Servo Actual Pulse(D) for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (air mix*1) actual pulse
for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (air mix*1) actual pulse
Min.: 0
Max.: 255
for LHD:
MAX. COLD: 5 (pulse)
MAX. HOT: 103 (pulse)
for RHD:
MAX. COLD: 105
MAX. HOT: 7
-
Air Mix Servo Targ Pulse(P) for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (air mix*2) target pulse
for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (air mix*2) target pulse
Min.: 0
Max.: 255
for LHD:
MAX. COLD: 105 (pulse)
MAX. HOT: 7 (pulse)
for RHD:
MAX. COLD: 5
MAX. HOT: 103
-
Air Mix Servo Actual Pulse(P) for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (air mix*2) actual pulse
for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (air mix*2) actual pulse
Min.: 0
Max.: 255
for LHD:
MAX. COLD: 105 (pulse)
MAX. HOT: 7 (pulse)
for RHD:
MAX. COLD: 5
MAX. HOT: 103
-
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) target pulse Min.: 0
Max.: 255
FACE: 8 (pulse)
B/L: 30 (pulse)
FOOT (Manual mode) : 67 (pulse)
FOOT (Automatic mode) : 60, 67 or 74 (pulse)
FOOT/DEF: 80 (pulse)
DEF: 97 (pulse)
-
Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse Min.: 0
Max.: 255
FACE: 8 (pulse)
B/L: 30 (pulse)
FOOT (Manual mode) : 67 (pulse)
FOOT (Automatic mode) : 60, 67 or 74 (pulse)
FOOT/DEF: 80 (pulse)
DEF: 97 (pulse)
-
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (air inlet) target pulse Min.: 0
Max.: 255
RECIRCULATION: 7 (pulse)
FRESH: 28 (pulse)
-
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly (air inlet) actual pulse Min.: 0
Max.: 255
RECIRCULATION: 7 (pulse)
FRESH: 28 (pulse)
-
Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr, 2C incr Customized value displayed -
Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed *3
Compressor Mode Compressor mode Auto or Manual Customized value displayed -
Evaporator Control Evaporator Control Auto or Manual Customized value displayed -
Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
Fan speed increment control Fan speed increment control Slow, Normal, Fast Customized value displayed -
Foot/DEF Auto Mode Foot/DEF Auto Mode ON or OFF Customized value displayed -
Foot/DEF Auto Blow Up Foot/DEF Auto blower speed increase ON or OFF Customized value displayed -
Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr Customized value displayed -
Flow Sensor Flow sensor Min.: 0 V
Max.: 5 V
A/C on, Blower switch HI: 0.7 to 3.8 V
A/C off, Blower switch off: 3.8 to 4.2 V
Flow sensor is malfunctioning when a constant value between 0.7 and 4.2 V is displayed continuously for more than 4 seconds.
A/C Cutoff Signal A/C control cutoff signal OFF or ON The ECM sends the air conditioning control cutoff signal displayed -
Outside Air Mode Auto Switch Function Outside air mode auto switch function ON or OFF Customized value displayed *3
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -

*1: for Driver Side

*2: for Front Passenger Side

*3: for RHD




ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0, Max.: 31 -
Magnetic Clutch Relay A/C system operation OFF, ON -
Defogger Relay (Rear) Defogger relay (engine room junction block assembly) OFF, ON -
Air Mix Servo Targ Pulse(D) for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (air mix*1) pulse
for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (air mix*1) pulse
Min.: 0, Max.: 255 for LHD:
Operates between 5 and 103 pulses
for RHD:
Operates between 7 and 105 pulses
Air Mix Servo Targ Pulse(P) for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (air mix*2) pulse
for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (air mix*2) pulse
Min.: 0, Max.: 255 for LHD:
Operates between 7 and 105 pulses
for RHD:
Operates between 5 and 103 pulses
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) pulse Min.: 0, Max.: 255 Perform Active Test when value between 8 and 97 displayed
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (air inlet) pulse Min.: 0, Max.: 255 Perform Active Test when value between 7 and 28 displayed

*1: for Driver Side

*2: for Front Passenger Side