Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM › 2012.02–2015.04
NM2040EQ _57 Power Source / Network _014507 NETWORKING _0073611 CAN COMMUNICATION SYSTEM GE GENERAL F

NETWORKING  CAN COMMUNICATION SYSTEM  GENERAL  GENERAL  


OUTLINE


a.

The Controller Area Network (CAN) uses 2 different types of CAN buses:

·

The CAN V bus, CAN sub bus 11 and CAN sub bus 15 are HS-CAN buses that operate at 500 kbps.

·

The CAN sub bus 1 is an MS-CAN bus that operates at 250 kbps.



b.

Each CAN bus has 2 terminating resistors which are necessary for accurate judgment of communication.


c.

The terminating resistors for each bus are located as shown in the following table.

Speed Communication Bus Terminating Resistor Location
High-speed (HS-CAN) CAN V Bus
·

ECM

·

Combination Meter Assembly


CAN Sub Bus 11
·

Power Management Control ECU

·

ST-Plug


CAN Sub Bus 15
·

ECM

·

Power Management Control ECU


Middle-speed (MS-CAN) CAN Sub Bus 1
·

Main Body ECU (Multiplex Network Body ECU)

·

Junction Connector RH




d.

The power management control ECU has a gateway function and is used to transmit data between the CAN V bus and CAN sub bus 11.


e.

The main body ECU (multiplex network body ECU) has a gateway function and is used to transmit data between the CAN V bus and CAN sub bus 1.