CONSTRUCTION
The battery smart unit monitors the conditions of the HV battery such as voltage, current and temperature, and transmits this information to the power management control ECU.
Also, the battery smart unit detects and transmits the blower speed feedback frequency which is necessary to perform the cooling system control, to the power management control ECU.
A leakage detection circuit is provided in the battery smart unit in order to detect any electrical leakage from the HV battery or high-voltage circuit.
The battery smart unit converts these signals into digital signals and transmits them to the power management control ECU via serial communication.