Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2015.04
NM2040EQ _51 Engine / Hybrid System _014483 HYBRID / BATTERY CONTROL _0073580 HYBRID CONTROL SYSTEM CO CONTROL F

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  CONTROL  THS-II CONTROL  


FUNCTION OF MAIN COMPONENTS


a.

The main components of the hybrid system have the following functions:

Component Function

*1: Models with multimedia system

*2: Models with navigation system

Power Management Control ECU Performs comprehensive control of the hybrid system.
·

Information from various sensors as well as from ECUs (ECM, MG ECU, battery smart unit and skid control ECU) is received, and based on this the required torque and output power is calculated. The power management control ECU transmits the calculated result to the ECM, MG ECU and skid control ECU.

·

Monitors the SOC of the HV battery.

·

Controls the DC-DC converter.

·

Controls the inverter water pump assembly.

·

Controls the inverter water pump assembly.


Hybrid Vehicle Transaxle Assembly Motor Generator No. 1 (MG1) MG1, which is driven by the engine, generates high-voltage electricity in order to operate MG2 and charge the HV battery. Also, it functions as a starter to start the engine.
Motor Generator No. 2 (MG2)
·

MG2, which is driven by electrical power from MG1 and the HV battery, generates motive force for the drive wheels.

·

During braking, or when the accelerator pedal is not depressed, it generates high-voltage electricity to recharge the HV battery.


Generator Resolver (For MG1) Detects the rotor position, rotational speed and direction of MG1.
Motor Resolver (For MG2) Detects the rotor position, rotational speed and direction of MG2.
Generator Temperature Sensor (For MG1) Detects the temperature of MG1.
Motor Temperature Sensor (For MG2) Detects the temperature of MG2.
Compound Gear Unit Power Split Planetary Gear Unit Distributes the engine motive force as appropriate to directly drive the vehicle as well as MG1.
Motor Speed Reduction Planetary Gear Unit Reduces the rotational speed of MG2 in accordance with the characteristics of the planetary gear, in order to increase torque.
Inverter with Converter Assembly Inverter Converts the direct current from the boost converter into alternating current for MG1 and MG2, and vice versa (from AC to DC).
Boost Converter Boosts the HV battery nominal voltage of DC 244.8 V up to a maximum voltage of DC 650 V and vice versa (drops DC 650 V to DC 244.8 V).
DC-DC Converter Drops the HV battery nominal voltage of DC 244.8 V to approximately DC 14 V in order to supply electricity to the electrical components, as well as to recharge the auxiliary battery.
MG ECU Controls the inverter and boost converter in accordance with the signals received from the power management control ECU, thus operating MG1 and MG2 as either a generator or motor.
Atmospheric Pressure Sensor Detects the atmospheric pressure.
Temperature Sensor for Inverter with Converter Assembly Detects temperatures in the parts of the inverter with converter assembly as well as the HV coolant temperature.
Inverter Current Sensor Detects the current of MG1 and MG2.
HV Battery Assembly HV Battery (Battery Modules)
·

Supplies electrical power to MG1 and MG2 in accordance with the driving conditions of the vehicle.

·

Recharged by MG1 and MG2 in accordance with the SOC and the driving conditions of the vehicle.


HV Battery Temperature Sensor Detects temperatures in the parts of the HV battery.
HV Battery Intake Air Temperature Sensor Detects the Intake air temperature from the battery cooling blower assembly.
Hybrid Battery Junction Block Assembly System Main Relays Connects and disconnects the high-voltage circuit between the HV battery and the inverter with converter assembly, through the use of signals from the power management control ECU.
Battery Current Sensor Detects the input and output current of the HV battery.
Battery Smart Unit
·

Monitors the conditions of the HV battery such as voltage, current and temperature, and transmits this information to the power management control ECU.

·

Monitors the high-voltage system for breakdown of the electrical insulation.


Service Plug Grip Shuts off the high-voltage circuit of the HV battery when the service plug grip is removed for vehicle inspection or maintenance.
Interlock Switch (for Service Plug Grip/for Terminal Cover (MG1)/for Terminal Cover (MG2)/for Connector Cover/for Power Cable Connector) Verifies that the service plug grip, terminal cover (MG1), terminal cover (MG2), connector cover and inverter power cable connector are installed.
Power Cable (Frame Wire) Connects the HV battery, inverter with converter assembly, hybrid vehicle transaxle assembly and compressor with motor assembly.
Inverter Water Pump Assembly Operates under the control of the power management control ECU in order to cool the inverter with converter assembly, MG1 and MG2.
Battery Cooling Blower Assembly Operates under the control of the power management control ECU in order to cool the HV battery.
Auxiliary Battery Supplies electricity to the electrical components.
Auxiliary Battery Temperature Sensor (Thermistor Assembly) Detects the temperature of the auxiliary battery.
Power Switch Starts and stops the hybrid system.
Accelerator Pedal Sensor Assembly Converts the accelerator pedal position into an electrical signal and sends it to the power management control ECU.
Shift Lever Position Sensor Converts the shift position into electrical signals and sends them to the power management control ECU.
Stop Light Switch Detects the depression of the brake pedal.
EV Drive Mode Switch (Pattern Select Switch Assembly) Sends the EV drive mode switch (pattern select switch assembly) signal to the power management control ECU when operated by the driver.
ECO Mode Switch (Eco Switch Assembly) Sends the ECO mode switch (eco switch assembly) signal to the power management control ECU via the air conditioning amplifier assembly when operated by the driver.
ECM
·

Performs control of the engine in accordance with the target engine speed and required engine motive force received from the power management control ECU.

·

Transmits various engine operating condition signals to the power management control ECU.


Skid Control ECU (Brake Booster with Master Cylinder Assembly)
·

During braking, it calculates the required regenerative braking force and transmits it to the power management control ECU.

·

Transmits the request to the power management control ECU to limit motive force while the TRC or VSC is operating.


Air Conditioning Amplifier Assembly Transmits various air conditioning state signals to the power management control ECU.
Airbag Sensor Assembly During a collision, it transmits the airbag deployment signal to the power management control ECU.
Combination Meter Assembly Hybrid System Indicator Displays the system power output and regenerative charging of the hybrid system.
READY Indicator Light Informs the driver that the vehicle is ready to drive.
Master Warning Light In this context, the primary function of this warning light is to inform the driver of a malfunction in the hybrid system or when the SOC of the HV battery is too low. The light illuminates simultaneously with the sounding of a warning buzzer.
EV Drive Indicator Light Turns on during EV driving.
EV Drive Mode Indicator Light Informs the driver that EV drive mode is selected.
Malfunction Indicator Lamp (MIL) Turns on when there is a malfunction in the hybrid control system and engine control system.
Multi-information Display
·

The multi-information display displays messages to inform the driver when a malfunction occurs. It also displays system status and operation instructions.

·

The master warning light may illuminate or blink and the buzzer may sound depending on the message displayed on the multi-information display.


Radio and Display Receiver Assembly*1 Displays the energy monitor.
Navigation Receiver Assembly*2



SYSTEM CONTROL


a.

Control List

i.

The hybrid system consists of the controls listed below.

Control Outline
Hybrid Vehicle Control
·

The power management control ECU calculates the target motive force based on the shift lever position sensor, the degree to which the accelerator pedal is depressed, and the vehicle speed. It performs control in order to create the target motive force by optimally combining MG1, MG2 and the engine.

·

The power management control ECU calculates the engine motive force based on the target motive force, which has been calculated based on the requirements of the driver and the driving conditions of the vehicle. In order to create this motive force, the power management control ECU transmits the signals to the ECM.

·

The power management control ECU monitors the SOC of the HV battery and the temperature of the HV battery, MG1 and MG2, in order to optimally control these items.


SOC Control
·

The power management control ECU calculates the SOC by estimating the charging and discharging amperage of the HV battery.

·

The power management control ECU constantly performs charge/discharge control based on the calculated SOC in order to maintain the SOC within its target range.


Engine Control The ECM receives the target engine speed and required engine motive force, which were sent from the power management control ECU, and controls the ETCS-i, fuel injection volume, ignition timing, VVT-i and EGR.
MG1 and MG2 Main Control
·

MG1, which is driven by the engine, generates high-voltage electricity in order to operate MG2 and charge the HV battery. Also, it functions as a starter to start the engine.

·

MG2, which is driven by electrical power from MG1 and the HV battery, generates motive force for the drive wheels.

·

MG2 generates high-voltage electricity to charge the HV battery during braking (regenerative braking cooperative control), or when the accelerator pedal is not being depressed (energy regeneration).

·

MG1 and MG2 are basically shut down when the shift lever is in N. In order to stop providing motive force, it is necessary to stop driving MG1 and MG2, because MG1 and MG2 are mechanically joined to the drive wheels.


Inverter Control
·

The inverter converts the direct current from the HV battery into alternating current for MG1 and MG2, or vice versa, in accordance with the signals provided by the power management control ECU via the MG ECU. In addition, the inverter is used to transfer power from MG1 to MG2.

·

The power management control ECU shuts down the inverter if it receives an overheating, overcurrent or voltage fault signal from the inverter via the MG ECU.


Boost Converter Control
·

The boost converter boosts the HV battery nominal voltage of DC 244.8 V up to a maximum voltage of DC 650 V, in accordance with the signals provided by the power management control ECU via the MG ECU.

·

The inverter converts the alternating current generated by MG1 or MG2 into the direct current. The boost converter drops the generated voltage of DC 650 V (maximum voltage) to approximately DC 244.8 V, in accordance with the signals provided by the power management control ECU via the MG ECU.


DC-DC Converter Control The DC-DC converter drops the HV battery nominal voltage of DC 244.8 V to approximately DC 14 V in order to supply electricity to the electrical components, as well as to recharge the auxiliary battery.
System Main Relay Control To ensure that it is possible to connect and disconnect the high-voltage circuits reliably, the power management control ECU controls the 3 system main relays to connect and disconnect the high-voltage circuits from the HV battery. The power management control ECU also uses the timing of the operation of the 3 system main relays to monitor the operation of the relay contacts.
Cooling System Control for Inverter with Converter Assembly In order to cool the inverter with converter assembly, MG1 and MG2, the power management control ECU regulates the inverter water pump assembly according to the signals from the temperature sensor for the inverter with converter assembly, the temperature sensor for MG1 and the temperature sensor for MG2.
Cooling System Control for HV Battery In order to maintain the HV battery temperature at the optimum level, the power management control ECU regulates the battery cooling blower assembly according to the signals from the HV battery temperature sensors and HV battery intake air temperature sensor.
Regenerative Braking Cooperative Control During braking, the skid control ECU calculates the required regenerative braking force and transmits it to the power management control ECU. Upon receiving this signal, the power management control ECU transmits the actual regenerative braking control value to the skid control ECU. Based on this result, the skid control ECU calculates and executes the required hydraulic braking force.
TRC/VSC Cooperative Control The skid control ECU transmits the request to the power management control ECU to limit motive force while the TRC or VSC is operating. The power management control ECU controls the engine and MG2 in accordance with the present driving conditions in order to suppress the motive force. For details, refer to Brake Control System.
During Collision Control During a collision, if the power management control ECU receives the airbag deployment signal from the airbag sensor assembly, it turns the system main relays off in order to shut off the high-voltage from the HV battery.
Cruise Control System Operation Control When the power management control ECU receives the cruise control switch signal, it controls the motive forces of the engine and MG2 to be an optimum combination in order to obtain the target vehicle speed by the driver's demand. For details, refer to Cruise Control System.
Shift Control The power management control ECU detects the driver's desired shift state (P, R, N, D or B) in accordance with the signals provided by the shift lever position sensor. Based on these inputs and vehicle operating conditions, the power management control ECU controls MG1, MG2 and the engine to match the selected shift state.
EV Drive Mode Control When the EV drive mode switch (pattern select switch assembly) is operated by the driver, the power management control ECU uses only MG2 to drive the vehicle if the operating conditions are satisfied.
ECO Mode Control When the ECO mode switch (eco switch assembly) is operated by the driver, the power management control ECU moderates the response of the accelerator pedal operation to support Eco driving.
Brake Override Control The driving torque is restricted when both the accelerator and brake pedals are depressed. (For the Activation Conditions and Inspection Method, refer to the Repair Manual)
Engine Immobiliser Prohibits fuel delivery, ignition and starting the hybrid control system if an attempt is made to start the hybrid control system with an invalid key.



b.

Hybrid System Activation (READY-on State)

i.

The hybrid system can be activated by pressing the power switch while the brake pedal is being depressed. At this time, the READY indicator light flashes until the system check is completed. When the READY indicator light turns on, the hybrid system has started and the vehicle is ready to drive.


ii.

Even if the driver turns the power switch on (READY), sometimes the power management control ECU will not start the engine. The engine will only start if conditions such as engine coolant temperature, SOC, HV battery temperature and electrical load require an engine start.


iii.

After driving, when the driver stops the vehicle and shift to the P range, the power management control ECU allows the engine to continue running. The engine will stop after the SOC, HV battery temperature and electrical load reach a specified level.

NOTICE:

When the hybrid system is unavoidably required to be stopped while driving, the system can be forced to stop by pressing and holding the power switch for approximately 2 or 3 seconds or more or pushing the power switch 3 times or more in a row. At this time, the power source will change to on (ACC).




c.

EV Drive Mode

i.

EV drive mode has been provided to reduce vehicle noise, such as when entering or leaving a garage, as well as reducing the production of exhaust fumes in a garage. When the EV drive mode switch (pattern select switch assembly) is operated by the driver, the power management control ECU uses only MG2 to drive the vehicle if the operating conditions are satisfied.


ii.

When all operating conditions are satisfied, pressing the EV drive mode switch (pattern select switch assembly) causes the vehicle to enter EV drive mode, and the EV drive mode indicator light will be illuminated. If any operating condition is not satisfied and the EV drive mode switch (pattern select switch assembly) is pressed, a message is displayed on the multi-information display to inform the driver that the EV drive mode switch (pattern select switch assembly) operation was rejected, and EV drive mode cannot be entered.


iii.

If any condition does not meet the operating conditions while the vehicle is traveling in EV drive mode, in order to inform the driver that EV drive mode will be canceled, the EV drive mode indicator light flashes 3 times and a buzzer sounds. When EV drive mode has automatically canceled, another message is displayed to indicate that EV drive mode has been canceled.


iv.

When all required conditions, some of which are listed below, are satisfied, EV drive mode can be used.

Operating Condition
·

The hybrid system temperature is not high. (The hybrid system temperature will be high when the outside air temperature is high or after the vehicle has traveled up a hill or at high speeds.)

·

The hybrid system temperature is not low. (The hybrid system temperature will be low after the vehicle has been left for a long time when the outside air temperature is low.)

·

The engine coolant temperature is approximately 20°C (68°F) or more.

·

The SOC is approximately 50% or more.

·

The vehicle speed is approximately 40 km/h (25 mph) or less.

·

The accelerator pedal depression amount is a certain level or below.

·

The defroster is off.

·

The cruise control system is not operating.



HINT:

The available cruising range during EV drive mode varies according to the SOC of the HV battery and the driving conditions such as road surfaces and hills. However, it is usually between several hundred meters (several hundred yards) and approximately 2 km (1.2 miles).




d.

ECO Mode Control

i.

During ECO mode, the power management control ECU optimizes fuel economy and driving performance by gently generating the motive force in comparison to accelerator pedal operation. At the same time, it supports Eco driving by optimizing the air conditioning performance.

W105421E02
3.698,1.344 3.573,0.76 3.573,0.76 3.375,0.76 true 3.948,1.458 4.052,1.917 4.052,1.917 4.208,1.917 true 0.125,0 3.073,0.292 2.948,0.292 12 false Motive Force Output Characteristics: 2.427,0.646 3.458,0.896 1.031,0.25 10 false Normal Control 4.271,1.813 5.677,2.063 1.406,0.25 10 false ECO Mode Control 2.781,2.375 4.615,2.625 1.833,0.25 10 false Accelerator Pedal Opening 1.302,1.156 2.125,1.719 0.823,0.563 10 false Motive Force Output



e.

Hybrid Vehicle Control

i.

The power management control ECU detects the degree to which the accelerator pedal is depressed using the signals from the accelerator pedal sensor assembly and detects the shift position signals from the shift lever position sensor. The power management control ECU receives the speed signals from the MG1 and MG2 resolvers via the MG ECU. The power management control ECU determines the driving conditions of the vehicle in accordance with this information, and optimally controls the motive forces of MG1, MG2 and the engine. Furthermore, the power management control ECU optimally controls the output and torque of MG1, MG2 and the engine in order to deliver lower fuel consumption and cleaner exhaust emissions.


ii.

The power management control ECU calculates the engine motive force based on the calculated target motive force, and by taking the SOC and the temperature of the HV battery into consideration. The value obtained by subtracting the engine motive force from the target motive force is the MG2 motive force.


iii.

The ECM performs control of the engine in accordance with the target engine speed and required engine motive force received from the power management control ECU. Furthermore, the power management control ECU appropriately operates MG1 and MG2 in order to provide the required MG1 generation force and the required MG2 motive force.

W105411E03
0.313,3.469 1.927,3.99 1.615,0.521 10 false Accelerator Pedal Sensor Assembly 0.271,4.469 2.021,4.854 1.75,0.385 10 false Shift Lever Position Sensor 0.396,5.594 1.073,5.833 0.677,0.24 10 false MG ECU 0.448,7.052 1.823,7.292 1.375,0.24 10 false Resolver (MG1, MG2) 0.385,6.115 2.073,6.5 1.688,0.385 10 false - Resolver Speed Signal 5.281,2.5 5.771,2.854 0.49,0.354 10 false ECM 5.302,3.01 6.521,3.458 1.219,0.448 10 false - Engine Control 5.094,4.833 5.885,5.24 0.792,0.406 10 false MG ECU 5.083,5.333 6.958,5.865 1.875,0.531 10 false - MG1 and MG2 Main Control 5.083,5.75 6.292,6.094 1.208,0.344 10 false - Inverter Control 5.073,6.135 6.635,6.448 1.563,0.313 10 false - Boost Converter Control 0.177,1.844 1.427,2.042 1.25,0.198 10 false Battery Smart Unit 0.156,2.458 2.125,2.875 1.969,0.417 10 false - HV Battery Condition (Voltage, Current, Temperature) 2.615,4.417 3.313,5.76 0.698,1.344 10 false Target Motive Force Calculation 2.635,2.198 3.344,2.896 0.708,0.698 10 false SOC Calculation 0.094,0 2.833,0.313 2.74,0.313 12 false Flow of Motive Force Calculation: 1.49,0.542 5.854,0.865 4.365,0.323 10 false (Target Motive Force) - (Engine Motive Force) = (MG2 Motive Force) 2.542,1.208 4.688,1.479 2.146,0.271 10 false Power Management Control ECU 3.813,4.083 4.531,5.021 0.719,0.938 10 false MG1 Generation Force Calculation 3.813,2.188 4.531,3.458 0.719,1.271 10 false Engine Motive Force Calculation 3.792,5.802 4.542,7.167 0.75,1.365 10 false MG2 Motive Force Calculation



f.

SOC Control

i.

The power management control ECU calculates the SOC of the HV battery based on the charge/discharge amperage detected by the battery current sensor. The power management control ECU constantly performs charge/discharge control based on the calculated SOC in order to maintain the SOC within its target range.


ii.

While the vehicle is in motion, the HV battery undergoes repetitive charge/discharge cycles, as it becomes discharged by MG2 during acceleration and charged by regenerative braking during deceleration.


iii.

When the SOC is below the lower level, the power management control ECU increases the power output of the engine to operate MG1, which charges the HV battery.


iv.

The battery smart unit converts the HV battery related signals (voltage, current and temperature) into digital signals, and transmits them to the power management control ECU via serial communication. These signals are needed to determine the SOC that is calculated by the power management control ECU.

W104329E03
0.417,0.26 1.969,0.729 1.552,0.469 10 false Battery Current Sensor 2.74,1.26 4.021,1.5 1.281,0.24 10 false Battery Smart Unit 4.115,1.927 5.615,2.188 1.5,0.26 10 false Serial Communication 0.448,1.25 1.427,1.469 0.979,0.219 10 false HV Battery 0.427,1.594 1.854,1.813 1.427,0.219 10 false - HV Battery Voltage 0.479,2.26 1.719,2.76 1.24,0.5 10 false HV Battery Temperature Sensor 5.646,1.25 6.896,1.75 1.25,0.5 10 false Power Management Control ECU



g.

Engine Control

i.

The ECM receives the target engine speed and required engine motive force, which were sent from the power management control ECU, and controls the ETCS-i, fuel injection volume, ignition timing, VVT-i and EGR.


ii.

The ECM transmits the operating conditions of the engine to the power management control ECU.


iii.

Upon receiving the engine stop signal from the power management control ECU in accordance with the basic hybrid vehicle control, the ECM will stop the engine.

W101256E10
5.771,0.573 6.844,0.854 1.073,0.281 10 false ETCS-i Control 5.771,1.156 6.729,1.635 0.958,0.479 10 false Fuel Injection Volume Control 5.781,2.135 6.698,2.573 0.917,0.438 10 false Ignition Timing Control 4.198,2.01 4.677,2.26 0.479,0.25 10 false ECM 0.667,3.979 2.01,4.198 1.344,0.219 10 false : CAN (Sub Bus 15) 1.906,1.406 3.615,1.625 1.708,0.219 10 false Engine Control Requests 1.802,2.281 3.75,2.5 1.948,0.219 10 false Engine Operating Conditions 0.313,1.521 1.552,1.979 1.24,0.458 10 false Power Management Control ECU 5.844,3.135 6.917,3.417 1.073,0.281 10 false VVT-i Control 5.854,3.719 6.927,4 1.073,0.281 10 false EGR Control



h.

MG1 and MG2 Main Control

i.

MG1, which is driven by the engine, generates high-voltage electricity in order to operate MG2 and charge the HV battery. Also, it functions as a starter to start the engine.


ii.

MG2, which is driven by electrical power from MG1 and the HV battery, generates motive force for the drive wheels.


iii.

MG2 generates high-voltage electricity to charge the HV battery during braking (regenerative braking cooperative control), or when the accelerator pedal is not being depressed (energy regeneration).


iv.

MG1 and MG2 are basically shut down when neutral (N) is selected. In order to stop providing motive force, it is necessary to stop driving MG1 and MG2, because MG1 and MG2 are mechanically joined to the drive wheels.


v.

The MG ECU controls the Insulated Gate Bipolar Transistors (IGBTs) in the Intelligent Power Module (IPM) based on the signals received from the power management control ECU. The IGBTs are used for switching for the U, V, and W phases of each motor generator. There are IGBTs that switch on and off to control each individual motor generator in accordance with operation as either a motor or as a generator.


vi.

The illustration below describes the basic control used when the motor generator functions as a motor. The IGBTs in the IPM switch on and off to supply three-phase alternating current to the motor generator. In order to create the motive force required of the motor generator as calculated by the power management control ECU, the MG ECU switches the IGBTs on and off in order to control the speed of the motor generator.

W101616E02
1.354,5.99 1.354,5.333 1.354,5.333 1.448,5.333 true 0.771,7.344 0.771,6.74 true 0.771,3.448 0.771,2.781 0.771,2.781 0.865,2.781 true 1.948,4.823 1.948,4.219 true 1.938,0.896 1.938,0.229 1.938,0.229 2.031,0.229 true 1.365,2.188 1.365,1.646 true 5.094,5.854 5.302,6.052 0.208,0.198 10 false U 4.635,5.625 4.938,5.844 0.302,0.219 10 false (+) 4.646,6.958 4.948,7.177 0.302,0.219 10 false (-) 5.594,5.854 5.802,6.052 0.208,0.198 10 false V 6.052,5.854 6.26,6.052 0.208,0.198 10 false W 3.49,5.844 3.698,6.042 0.208,0.198 10 false U 3,6.635 3.208,6.833 0.208,0.198 10 false V 3.823,6.625 4.031,6.823 0.208,0.198 10 false W 3.052,6.865 4.646,7.083 1.594,0.219 10 false Motor Generator 2.25,7.146 2.615,7.365 0.365,0.219 10 false IPM 1.531,5.24 2.313,5.458 0.781,0.219 10 false IGBT: ON 0.458,7.365 1.24,7.583 0.781,0.219 10 false IGBT: ON 5.094,3.313 5.302,3.51 0.208,0.198 10 false U 4.635,3.115 4.938,3.333 0.302,0.219 10 false (+) 4.646,4.406 4.948,4.625 0.302,0.219 10 false (-) 5.594,3.313 5.802,3.51 0.208,0.198 10 false V 6.052,3.313 6.26,3.51 0.208,0.198 10 false W 3.479,3.313 3.688,3.51 0.208,0.198 10 false U 3,4.052 3.208,4.25 0.208,0.198 10 false V 3.823,4.073 4.031,4.271 0.208,0.198 10 false W 3.063,4.396 4.656,4.615 1.594,0.219 10 false Motor Generator 2.25,4.604 2.615,4.823 0.365,0.219 10 false IPM 0.927,2.688 1.708,2.906 0.781,0.219 10 false IGBT: ON 1.625,4.833 2.406,5.052 0.781,0.219 10 false IGBT: ON 5.094,0.76 5.302,0.958 0.208,0.198 10 false U 4.635,0.563 4.938,0.781 0.302,0.219 10 false (+) 4.646,1.865 4.948,2.083 0.302,0.219 10 false (-) 5.594,0.76 5.802,0.958 0.208,0.198 10 false V 6.052,0.76 6.26,0.958 0.208,0.198 10 false W 3.49,0.771 3.698,0.969 0.208,0.198 10 false U 3,1.563 3.208,1.76 0.208,0.198 10 false V 3.823,1.552 4.031,1.75 0.208,0.198 10 false W 3.063,1.844 4.656,2.063 1.594,0.219 10 false Motor Generator 2.25,2.063 2.615,2.281 0.365,0.219 10 false IPM 2.115,0.125 2.896,0.344 0.781,0.219 10 false IGBT: ON 1.063,2.271 1.844,2.49 0.781,0.219 10 false IGBT: ON


vii.

The illustration below describes the basic control used when the motor generator functions as a generator. The current that is generated sequentially by the 3 phases of the motor generator, which is driven by the wheels, is utilized to charge the HV battery or drive another motor generator.

W101617E05
5.094,5.854 5.302,6.052 0.208,0.198 10 false U 4.635,5.646 4.938,5.865 0.302,0.219 10 false (+) 4.646,6.969 4.948,7.188 0.302,0.219 10 false (-) 5.594,5.854 5.802,6.052 0.208,0.198 10 false V 6.052,5.854 6.26,6.052 0.208,0.198 10 false W 3.49,5.833 3.698,6.031 0.208,0.198 10 false U 3,6.667 3.208,6.865 0.208,0.198 10 false V 3.823,6.646 4.031,6.844 0.208,0.198 10 false W 3,6.885 4.594,7.104 1.594,0.219 10 false Motor Generator 2.229,7.156 2.594,7.375 0.365,0.219 10 false IPM 5.094,3.313 5.302,3.51 0.208,0.198 10 false U 4.635,3.104 4.938,3.323 0.302,0.219 10 false (+) 4.646,4.448 4.948,4.667 0.302,0.219 10 false (-) 5.594,3.313 5.802,3.51 0.208,0.198 10 false V 6.052,3.313 6.26,3.51 0.208,0.198 10 false W 3.49,3.281 3.698,3.479 0.208,0.198 10 false U 3,4.063 3.208,4.26 0.208,0.198 10 false V 3.823,4.073 4.031,4.271 0.208,0.198 10 false W 3,4.385 4.594,4.604 1.594,0.219 10 false Motor Generator 2.25,4.615 2.615,4.833 0.365,0.219 10 false IPM 5.094,0.76 5.302,0.958 0.208,0.198 10 false U 4.635,0.552 4.938,0.771 0.302,0.219 10 false (+) 4.646,1.906 4.948,2.125 0.302,0.219 10 false (-) 5.594,0.76 5.802,0.958 0.208,0.198 10 false V 6.052,0.76 6.26,0.958 0.208,0.198 10 false W 3.49,0.76 3.698,0.958 0.208,0.198 10 false U 3,1.542 3.208,1.74 0.208,0.198 10 false V 3.823,1.542 4.031,1.74 0.208,0.198 10 false W 3,1.844 4.594,2.063 1.594,0.219 10 false Motor Generator 2.25,2.073 2.615,2.292 0.365,0.219 10 false IPM



i.

Inverter Control

i.

The inverter converts the direct current from the HV battery into alternating current for MG1 and MG2, or vice versa. In addition, the inverter takes power generated by MG1 and supplies it to MG2. However, the electricity generated by MG1 is converted into the direct current inside the inverter before being converted back into the alternating current by the inverter for use by MG2. This is necessary because the frequency of the alternating current output by MG1 is not appropriate for control of MG2.


ii.

The MG ECU controls the IPMs for switching the three-phase alternating current of MG1 and MG2 in accordance with the signals received from the power management control ECU.


iii.

When the power management control ECU has received an overheating, overcurrent, or voltage fault signal from the MG ECU, the power management control ECU transmits a shut down control signal to the MG ECU, in order to turn off the IPMs.

W101618E10
2.104,3.51 3.396,3.823 1.292,0.313 10 false Boost Converter 2.292,4.625 3.302,4.917 1.01,0.292 10 false HV Battery 3.125,1.115 3.854,1.656 0.729,0.542 10 false Alternating Current 0.229,1.115 1.615,1.448 1.385,0.333 10 false Alternating Current 0.333,3.271 1.469,3.906 1.135,0.635 10 false Maximum Voltage of DC 650 V 0.406,4.219 1.438,4.917 1.031,0.698 10 false Nominal Voltage of DC 244.8 V 0.531,2.875 1.51,3.208 0.979,0.333 10 false Direct Current 4.188,3.521 4.885,3.844 0.698,0.323 10 false MG ECU 3.177,2.958 4.042,3.208 0.865,0.25 10 false Inverter 2.302,2.344 3.365,2.677 1.063,0.333 10 false IPM for MG1 2.552,0.51 2.99,0.76 0.438,0.25 10 false MG1 3.688,2.344 4.75,2.677 1.063,0.333 10 false IPM for MG2 3.938,0.51 4.375,0.76 0.438,0.25 10 false MG2 4.365,4.625 5.635,5.063 1.271,0.438 10 false Power Management Control ECU 5.208,1.802 6.604,2.292 1.396,0.49 10 false Inverter with Converter Assembly 4.531,4.188 6.156,4.531 1.625,0.344 10 false Serial Communication



j.

Boost Converter Control

i.

The boost converter boosts the HV battery nominal voltage of DC 244.8 V up to a maximum voltage of DC 650 V, in accordance with the signals provided by the power management control ECU via the MG ECU.


ii.

The inverter converts the alternating current generated by MG1 or MG2 into direct current. The boost converter drops the generated voltage of DC 650 V (maximum voltage) to approximately DC 244.8 V, in accordance with the signals provided by the power management control ECU via the MG ECU.


iii.

The boost converter consists of the boost IPM with built-in IGBTs that perform switching control, the reactor that stores the electrical power and generates the electromotive force, and the capacitor that charges and discharges the boosted high-voltage electricity.

W105413E04
5.479,3.146 5.479,1.458 5.479,1.458 5.365,1.458 true 0.427,1.771 1.365,2.115 0.938,0.344 10 false HV Battery 3.417,2.792 4.365,3.135 0.948,0.344 10 false Boost IPM 6.031,2.76 6.979,3.135 0.948,0.375 10 false Inverter 2.823,1.344 3.719,1.833 0.896,0.49 10 false IGBT2 for Voltage Boost 2.854,0.542 3.688,0.99 0.833,0.448 10 false IGBT1 for Voltage Drop 5.188,3.135 6.167,3.469 0.979,0.333 10 false Capacitor 2.052,1.521 2.771,1.854 0.719,0.333 10 false Reactor


iv.

The flow of the boost converter boosting is as described below.

Step Outline
1 IGBT2 turns on, causing the voltage of the HV battery (nominal voltage of DC 244.8 V) to charge the reactor. As a result, the reactor stores the electrical power.
2 IGBT2 turns off, causing the reactor to produce an electromotive force (the current continues to flow from the reactor). This electromotive force causes the voltage to rise to a maximum voltage of DC 650 V. Induced by the electromotive force that is created by the reactor, the current that is flowing from the reactor flows into the inverter and the capacitor at the boosted voltage.
3 IGBT2 turns on again to cause the voltage of the HV battery to charge the reactor. While this happens, by discharging the electrical power (maximum voltage of DC 650 V) stored in the capacitor, electrical power continues to be supplied to the inverter.

W105414E03
5.552,2.344 5.552,1.594 5.552,1.594 5.448,1.594 true 2.104,1.281 2.104,1.125 2.104,1.125 1.979,1.125 true 5.583,5.563 5.583,4.813 5.583,4.813 5.479,4.813 true 2.104,4.51 2.104,4.344 2.104,4.344 1.979,4.344 true 4.813,4.135 4.813,3.604 4.813,3.604 4.927,3.604 true 5.583,8.802 5.583,8.063 5.583,8.063 5.469,8.063 true 5.49,7.354 5.49,6.813 5.49,6.813 5.365,6.813 true 2.104,7.76 2.104,7.594 2.104,7.594 1.979,7.594 true 0.188,1.76 1.219,2.573 1.031,0.813 10 false HV Battery: Nominal Voltage of DC 244.8 V 3.365,2.948 4.313,3.229 0.948,0.281 10 false Boost IPM 6.104,2.917 6.594,3.198 0.49,0.281 10 false Inverter 5.094,2.375 5.729,2.729 0.635,0.354 10 false Capacitor 1.458,1.021 2.052,1.323 0.594,0.302 10 false Reactor 3.115,1.635 3.885,1.969 0.771,0.333 10 false IGBT2: ON 3.073,0.948 3.875,1.292 0.802,0.344 10 false IGBT1: OFF 0.104,0 0.792,0.406 0.688,0.406 12 false Step 1: 0.167,4.948 1.208,5.74 1.042,0.792 10 false HV Battery: Nominal Voltage of DC 244.8 V 3.375,6.167 4.323,6.542 0.948,0.375 10 false Boost IPM 6.094,6.156 7.042,6.573 0.948,0.417 10 false Inverter 5.104,5.604 5.74,5.969 0.635,0.365 10 false Capacitor 4.958,3.5 6.99,3.854 2.031,0.354 10 false Maximum Voltage of DC 650 V 1.469,4.24 2.031,4.573 0.563,0.333 10 false Reactor 3.104,4.854 3.969,5.24 0.865,0.385 10 false IGBT2: OFF 3.073,4.198 3.875,4.458 0.802,0.26 10 false IGBT1: OFF 0.104,3.094 0.792,3.5 0.688,0.406 12 false Step 2: 0.177,8.24 1.229,8.875 1.052,0.635 10 false HV Battery: Nominal Voltage of DC 244.8 V 3.365,9.417 4.313,9.771 0.948,0.354 10 false Boost IPM 6.125,9.427 6.615,9.75 0.49,0.323 10 false Inverter 5.135,8.813 5.823,9.219 0.688,0.406 10 false Capacitor 3.448,6.708 5.479,7.073 2.031,0.365 10 false Maximum Voltage of DC 650 V 3.167,8.104 3.865,8.479 0.698,0.375 10 false IGBT2: ON 3.104,7.438 3.927,7.729 0.823,0.292 10 false IGBT1: OFF 1.458,7.49 2.052,7.844 0.594,0.354 10 false Reactor 0.104,6.333 0.792,6.646 0.688,0.313 12 false Step 3:


v.

The alternating current which is generated by MG1 or MG2 for the purpose of charging the HV battery is converted into direct current (maximum voltage of DC 650 V) by the inverter. Then, the boost converter is used to drop the voltage to approximately DC 244.8 V. This is accomplished by IGBT1 being switched on and off using duty cycle control, intermittently interrupting the electrical power provided to the reactor by the inverter.

W105415E03
1.979,1.698 1.979,1.313 1.979,1.313 1.854,1.313 true 3.927,1.333 3.927,0.375 3.927,0.375 3.802,0.375 true 4.844,1.042 4.844,0.656 4.844,0.656 4.958,0.656 true 5.177,2.656 5.177,1.906 5.177,1.906 5.281,1.906 true 3.479,3.271 4.427,3.51 0.948,0.24 10 false Boost IPM 6.094,3.26 7.042,3.5 0.948,0.24 10 false Inverter 2.104,2 2.771,2.24 0.667,0.24 10 false Reactor 0.177,1.208 1.917,1.448 1.74,0.24 10 false Approximately DC 244.8 V 2.031,0.208 3.771,0.719 1.74,0.51 10 false IGBT1: ON/OFF Switching Control (Duty Cycle Control) 3.083,1.979 3.875,2.229 0.792,0.25 10 false IGBT2: OFF 5.021,0.552 7.052,0.792 2.031,0.24 10 false Maximum Voltage of DC 650 V 0.083,2.146 1.125,2.698 1.042,0.552 10 false HV Battery: Nominal Voltage of DC 244.8 V 5,2.667 5.688,3.073 0.688,0.406 10 false Capacitor



k.

DC-DC Converter Control

i.

The DC-DC converter drops the HV battery nominal voltage of DC 244.8 V to approximately DC 14 V in order to supply electricity to the electrical components, as well as to recharge the auxiliary battery.


ii.

In order to regulate the output voltage from the DC-DC converter, the power management control ECU transmits an output voltage request signal to the DC-DC converter in response to auxiliary battery temperature sensor signals.

W105601E02
4.042,0.667 5.188,0.885 1.146,0.219 10 false Electrical Loads 1.729,0.542 2.333,0.948 0.604,0.406 10 false DC-DC Converter 5.094,2.74 6.958,3.229 1.865,0.49 10 false Auxiliary Battery Temperature Sensor (Thermistor Assembly) 0.448,2.063 1.198,2.635 0.75,0.573 10 false Inverter with Converter Assembly 6.208,1.417 6.771,1.885 0.563,0.469 10 false Auxiliary Battery 0.073,0.958 0.906,1.198 0.833,0.24 10 false HV Battery 3,2.75 4.25,3.167 1.25,0.417 10 false Power Management Control ECU



l.

System Main Relay Control

i.

The power management control ECU controls the system main relays to connect and disconnect the high-voltage circuit from the HV battery. The power management control ECU also uses the timing of the operation of the system main relays to monitor the operation of the relay contacts.


ii.

A total of 3 relays, 1 for the positive side (SMRB) and 2 for the negative side (SMRP, SMRG), are provided to ensure proper operation.

W105417E04
5.156,0.594 6.458,0.813 1.302,0.219 10 false Battery Smart Unit 1.542,0.594 2.823,1.063 1.281,0.469 10 false Power Management Control ECU 5.938,2.167 6.917,2.76 0.979,0.594 10 false To Power Cable (Frame Wire) 3.094,2.771 3.635,2.99 0.542,0.219 10 false SMRB 3.094,3.646 3.635,3.865 0.542,0.219 10 false SMRP 3.094,4.542 3.635,4.76 0.542,0.219 10 false SMRG 0.156,3.313 0.896,3.552 0.74,0.24 10 false HV Battery 0.927,4.958 3.646,5.198 2.719,0.24 10 false Hybrid Battery Junction Block Assembly 1.719,3.479 2.365,3.896 0.646,0.417 10 false Precharge Resistor 4.563,2.625 5.552,3.104 0.99,0.479 10 false Battery Current Sensor 3.25,1.052 4.698,1.271 1.448,0.219 10 false Serial Communication 5.938,3.917 6.906,4.542 0.969,0.625 10 false To Power Cable (Frame Wire)


iii.

When the hybrid system changes to the READY-on state, the power management control ECU turns on SMRB and SMRP in sequence, and applies the current through the precharge resistor. After that, it turns SMRG on, and applies the current by bypassing the precharge resistor. Then it turns SMRP off. As the controlled current is initially allowed to pass through the precharge resistor in this manner, the contact point in the circuit is protected from damage that could be caused by an inrush current.

W105418E04
1.656,0.938 2.51,1.208 0.854,0.271 10 false SMRB: ON 1.688,1.625 2.542,1.896 0.854,0.271 10 false SMRP: OFF 1.688,2.302 2.542,2.573 0.854,0.271 10 false SMRG: OFF 5.448,0.938 6.302,1.208 0.854,0.271 10 false SMRB: ON 5.427,1.615 6.281,1.885 0.854,0.271 10 false SMRP: ON 5.396,2.302 6.25,2.573 0.854,0.271 10 false SMRG: OFF 1.688,3.771 2.542,4.042 0.854,0.271 10 false SMRB: ON 1.677,4.458 2.531,4.729 0.854,0.271 10 false SMRP: ON 1.688,5.135 2.542,5.406 0.854,0.271 10 false SMRG: ON 5.417,3.781 6.271,4.052 0.854,0.271 10 false SMRB: ON 5.406,4.458 6.26,4.729 0.854,0.271 10 false SMRP: OFF 5.448,5.135 6.302,5.406 0.854,0.271 10 false SMRG: ON


iv.

When the hybrid system changes to a state other than the READY-on state, the power management control ECU turns SMRG off first. Next, it turns SMRB off after determining whether or not SMRG is operating properly. After that, it turns on SMRP and then off after determining whether or not SMRB is operating properly. As a result, the power management control ECU verifies that the respective relays have been properly turned off.

W105419E04
1.635,0.948 2.49,1.125 0.854,0.177 10 false SMRB: ON 1.635,1.635 2.531,1.813 0.896,0.177 10 false SMRP: OFF 1.635,2.302 2.531,2.479 0.896,0.177 10 false SMRG: OFF 5.385,0.948 6.25,1.125 0.865,0.177 10 false SMRB: OFF 5.385,1.625 6.281,1.802 0.896,0.177 10 false SMRP: OFF 5.385,2.302 6.281,2.479 0.896,0.177 10 false SMRG: OFF 1.635,3.781 2.531,3.958 0.896,0.177 10 false SMRB: OFF 1.635,4.469 2.531,4.646 0.896,0.177 10 false SMRP: ON 1.635,5.146 2.531,5.323 0.896,0.177 10 false SMRG: OFF 5.438,3.781 6.333,3.958 0.896,0.177 10 false SMRB: OFF 5.385,4.458 6.281,4.635 0.896,0.177 10 false SMRP: OFF 5.385,5.146 6.281,5.323 0.896,0.177 10 false SMRG: OFF



m.

Cooling System Control for Inverter with Converter Assembly

i.

The power management control ECU receives the signals from the temperature sensors for the inverter with converter assembly, temperature sensor for MG1 and temperature sensor for MG2. Then, the power management control ECU actuates the inverter water pump assembly over 3 levels using duty cycle control, in order to cool the inverter with converter assembly, MG1 and MG2.


ii.

When the HV coolant temperature rises above a certain level, the power management control ECU transmits a radiator fan drive request signal to the ECM. In response to that signal, the ECM actuates the radiator fan to restrain the HV coolant temperature increase, ensuring the cooling of the inverter with converter assembly, MG1 and MG2.


iii.

The MG ECU converts the temperature sensor signals into digital signals, and transmits them to the power management control ECU via serial communication.

W101626E19
2.927,0.479 3.604,0.74 0.677,0.26 10 false MG ECU 0.438,0.208 0.896,0.438 0.458,0.229 10 false ECM 0.438,0.521 2.031,0.792 1.594,0.271 10 false - Radiator Fan Control 0.948,2.281 3.104,2.5 2.156,0.219 10 false Power Management Control ECU 0.771,4.552 1.365,4.99 0.594,0.438 10 false Auxiliary Battery 1.01,3.917 2.01,4.198 1,0.281 10 false IGCT Relay 1.25,1.333 2.49,1.615 1.24,0.281 10 false CAN (Sub Bus 15) 4.229,0.354 6.635,0.771 2.406,0.417 10 false Temperature Sensor (4 Module Temp. / HV Coolant Temp.) 4.552,2.24 6.521,2.542 1.969,0.302 10 false Temperature Sensor (for MG1) 4.552,2.76 6.656,3.104 2.104,0.344 10 false Temperature Sensor (for MG2) 4.094,3.323 6.438,3.604 2.344,0.281 10 false Hybrid Vehicle Transaxle Assembly 4.094,1.292 6.552,1.573 2.458,0.281 10 false Inverter with Converter Assembly 3.115,5.125 5.417,5.333 2.302,0.208 10 false Inverter Water Pump Assembly 2.49,4.219 3.531,4.625 1.042,0.406 10 false Motor Controller 3.25,1.677 4.792,1.917 1.542,0.24 10 false Serial Communication



n.

Cooling System Control for HV Battery

i.

The power management control ECU receives the signals from the HV battery temperature sensors and HV battery intake air temperature sensor. Then, the power management control ECU steplessly actuates the battery cooling blower assembly using duty cycle control, in order to maintain the HV battery temperature within the specified range.


ii.

While the air conditioning system is operating and cooling down the cabin, and if there is any leeway in the HV battery temperature, the power management control ECU turns the battery cooling blower assembly off or sets it to a low speed. The purpose of this control is to give priority to cooling down the cabin. If this control is not performed, air taken from the cabin for battery cooling assembly would slow the cooling of the cabin by the air conditioning system.


iii.

The battery smart unit converts the HV battery related signals (voltage, current and temperature) into digital signals, and transmits them to the power management control ECU via serial communication. Also, the battery smart unit detects and transmits the blower speed feedback frequency which is necessary to perform the cooling system control, to the power management control ECU.

W104321E06
5.073,0.24 6.604,0.667 1.531,0.427 10 false HV Battery Temperature Sensors (3) 3.365,0.24 4.708,0.635 1.344,0.396 10 false HV Battery Intake Air Temperature Sensor 4.729,2 6.448,2.281 1.719,0.281 10 false Battery Smart Unit 0.406,0.594 2.813,0.865 2.406,0.271 10 false Air Conditioning Amplifier Assembly 0.823,1.979 2.094,2.333 1.271,0.354 10 false Power Management Control ECU 0.76,4.458 1.958,4.656 1.198,0.198 10 false Auxiliary Battery 0.948,3.635 2.25,3.917 1.302,0.281 10 false IGCT Relay 3.802,4.938 5.979,5.135 2.177,0.198 10 false Battery Cooling Blower Assembly 3.198,4.01 4.281,4.25 1.083,0.24 10 false Motor Controller 1.5,1.469 2.406,1.677 0.906,0.208 10 false CAN (V Bus) 3.302,1.375 4.302,1.604 1,0.229 10 false HV Battery 2.51,2.385 4.177,2.813 1.667,0.427 10 false Serial Communication



o.

Regenerative Braking Cooperative Control

i.

The skid control ECU calculates the total braking force needed based on the brake regulator pressure and brake pedal stroke when the driver depresses the brake pedal.


ii.

After calculating the required total braking force, the skid control ECU sends a regenerative braking force request to the power management control ECU. The power management control ECU replies with the amount of actual regenerative braking (regenerative braking control value).


iii.

The power management control ECU uses MG2 to create the minus torque (deceleration force), thus carrying out the regenerative braking.


iv.

The skid control ECU controls the brake actuator solenoid valves and generates the wheel cylinder pressure. The pressure that is generated is what remains after the actual regenerative braking control value has been subtracted from the required total braking force.

W105266E11
5.729,1.24 6.521,1.49 0.792,0.25 10 false MG ECU 5.313,0.219 6.677,0.76 1.365,0.542 10 false Inverter with Converter Assembly 3.885,2.698 6.625,2.948 2.74,0.25 10 false Actual Regenerative Braking Control Value 1.094,2.708 3.448,2.969 2.354,0.26 10 false Regenerative Brake Force Request 0.292,3.135 2.469,3.51 2.177,0.375 10 false Brake Booster with Master Cylinder Assembly 2.938,3.5 4.531,3.75 1.594,0.25 10 false Skid Control ECU 0.385,3.906 2.094,4.323 1.708,0.417 10 false Regulator Pressure Sensor 0.531,4.844 1.927,5.24 1.396,0.396 10 false Accumulator Pressure Sensor 0.448,5.802 2.01,6.198 1.563,0.396 10 false Wheel Cylinder Pressure Sensor 2.917,4.104 4.229,4.552 1.313,0.448 10 false Required Total Brake Force Calculation 2.76,5.115 4.365,5.563 1.604,0.448 10 false Regenerative Brake Force Request Calculation 2.781,6.125 4.365,6.552 1.583,0.427 10 false Required Hydraulic Brake Force Calculation 0.677,6.75 1.813,7 1.135,0.25 10 false Solenoid Valves 2.979,0.219 4.24,0.677 1.26,0.458 10 false Power Management Control ECU 2.875,1.24 4.281,1.833 1.406,0.594 10 false MG2 Generation Force (Regenerative Braking Force) Calculation 5.5,2.25 5.938,2.5 0.438,0.25 10 false MG1 6.219,2.25 6.656,2.5 0.438,0.25 10 false MG2 0.396,0.74 1.635,0.99 1.24,0.25 10 false Battery Smart Unit 0.427,1.26 1.823,1.896 1.396,0.635 10 false - HV Battery Condition (Voltage, Current, Temperature) 0.615,7.427 2.031,7.646 1.417,0.219 10 false : CAN (Sub Bus 15) 3.458,7.427 5.167,7.646 1.708,0.219 10 false : Serial Communication 5.375,4.24 6.615,4.74 1.24,0.5 10 false Brake Pedal Stroke Sensor Assembly 5.49,5.979 6.646,6.25 1.156,0.271 10 false Speed Sensors




FUNCTION


a.

Message of Multi-information Display

i.

The multi-information display displays messages to inform the driver when a malfunction occurs. It also displays system status and operation instructions.


ii.

The master warning light may illuminate or blink and the buzzer may sound depending on the message displayed on the multi-information display.

Message Message Content Explanation Master Warning Light Buzzer

*: The EV drive mode indicator light flashes 3 times.

SHIFT TO P POSITION TO START The shift lever must be in P when activating the hybrid system. Blinks Sounds
SHIFT TO P POSITION WHEN PARKED The shift lever must be in P when the vehicle is stopped for an extended period of time. Blinks Sounds
TRACTION BATTERY LOW. CHARGES WHEN NOT IN N POSITION Because the SOC of the HV battery is low, stop the vehicle and then move the shift lever to P. Blinks Sounds
TRACTION BATTERY PRESERVATION MODE, RESTART AFTER SHIFTING TO THE P POSITION Indicates that the hybrid battery (traction battery) power has dropped because a long period of time has elapsed after shifting the shift lever to N. Blinks Sounds
N POSITION Indicates that the accelerator pedal is depressed while the shift lever is in N. Blinks Sounds
CHECK HYBRID SYSTEM Hybrid system is malfunctioning. Illuminates Sounds
HYBRID SYSTEM OVERHEAT The temperatures of parts related to the hybrid system exceed the specified value. Illuminates Sounds
EV MODE NOT AVAILABLE WARMING UP EV drive mode is not available because the hybrid system is warming up. - Sounds
EV MODE NOT AVAILABLE LOW BATTERY EV drive mode is not available because the HV battery SOC is low. - Sounds
EV MODE NOT AVAILABLE EXCESSIVE SPEED EV drive mode is not available because the vehicle speed exceeds the operating condition. - Sounds
EV MODE NOT AVAILABLE EXCESSIVE ACCELERATION EV drive mode is not available because the accelerator pedal depression amount exceeds the operating condition. - Sounds
EV MODE CURRENTLY NOT AVAILABLE EV drive mode is not available because other operating conditions have not been met. - Sounds
EV MODE DEACTIVATED LOW BATTERY EV drive mode is deactivated because the HV battery SOC is low. -* Sounds
EV MODE DEACTIVATED EXCESSIVE SPEED EV drive mode is deactivated because the vehicle speed has exceed the operating condition. -* Sounds
EV MODE DEACTIVATED EXCESSIVE ACCELERATION EV drive mode is deactivated because the accelerator pedal depression amount has exceed the operating condition. -* Sounds
EV MODE DEACTIVATED EV drive mode is deactivated because the vehicle has no longer satisfied other operating conditions. -* Sounds



b.

Energy Monitor

i.

The energy monitor displayed in the multi-information display and/or radio display receiver assembly*1 or navigation receiver assembly*2 shows the energy flow of the hybrid system and the SOC of the HV battery based on information from the power management control ECU. The energy monitor shows the energy flow and shows the SOC in 8 levels.

*1: Models with display audio system

*2: Models with HDD navigation system

W107075C01
5.344,1.771 5.344,2.094 true 1.49,2.198 1.969,2.375 0.479,0.177 10 false *1 (*A) 1.49,4.51 2.094,4.729 0.604,0.219 10 false *2 (*B) 3.635,0.25 3.917,0.49 0.281,0.24 10 false *3 5.271,2.115 5.5,2.302 0.229,0.188 10 false *4
*A Models with Display Audio System *B Models with HDD Navigation System
*1 Radio and Display Receiver Assembly *2 Navigation Receiver Assembly
*3 Combination Meter Assembly *4 Multi-information Display





DIAGNOSIS


a.

When the power management control ECU detects a malfunction in the hybrid system, the power management control ECU performs diagnosis and memorizes information related to the fault. To inform the driver of the malfunction, the power management control ECU illuminates or blinks the Malfunction Indicator Lamp (MIL), master warning light and displays a message in the multi-information display. At the same time, a Diagnostic Trouble Code (DTC) is stored in memory.


b.

3-digit information codes (INF codes) are provided with the conventional DTC as subset of the primary 5-digit code. This enables the troubleshooting procedure to further narrow down a trouble area to identify a problem.


c.

The DTC can be read by connecting the intelligent tester to the DLC3. For details, refer to the Repair Manual.