RM2040EQ
_V1
General
_014689
SPECIFICATIONS
_0074824
2AR-FXE COOLING
F
SPECIFICATIONS 2AR-FXE COOLING SERVICE DATA
THERMOSTAT
| Condition
|
Specified Condition
|
| Standard valve opening temperature
|
80 to 84°C (176 to 183°F)
|
| Standard valve lift
|
10 to 11.3 mm (0.394 to 0.445 in.) at 95°C (203°F)
|
COOLING FAN MOTOR
| Item
|
Condition
|
Specified Condition
|
| Cooling fan motor
|
Auxiliary battery voltage applied at 20°C (68°F)
|
10.6 to 16.6 A
|
| No. 2 cooling fan motor
|
Auxiliary battery voltage applied at 20°C (68°F)
|
10.6 to 16.6 A
|
COOLING FAN RELAY
| Item
|
Tester Connection
|
Specified Condition
|
| Cooling fan relay
|
3 - 5
|
10 kΩor higher
(Battery voltage is not applied between terminals 1 and 2)
|
| 3 - 5
|
Below 1 Ω
(Battery voltage is applied between terminals 1 and 2)
|
RADIATOR
| Item
|
Condition
|
Specified Condition
|
| Radiator cap
|
Standard value (for brand-new cap)
|
93.3 to 122.7 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18.0 psi)
|
| Minimum standard value (for used cap)
|
78.5 kPa (0.8 kgf/cm2, 11.4 psi)
|
COOLANT
| Capacity
|
Classification
|
| 7.8 liters (8.2 US qts, 6.9 Imp. qts)
|
Use only "TOYOTA Super Long Life Coolant", or similar high qualityethylene glycol based non-silicate, non-amine, non-nitrite, and nonboratecoolant with long-life hybrid organic acid technology (coolantwith long-life hybrid organic acid technology is a combination of lowphosphates and organic acids).
|