Home › Engine / Hybrid System › 2AR-FXE ENGINE CONTROL › KNOCK SENSOR
RM2040EQ _51 Engine / Hybrid System _014691 2AR-FXE ENGINE CONTROL _0074881 KNOCK SENSOR G

2AR-FXE ENGINE CONTROL  KNOCK SENSOR  INSPECTION  


PROCEDURE

Hide 89615 1.INSPECT KNOCK CONTROL SENSOR

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 120 to 280 kΩ


If the result is not as specified, replace the knock control sensor.