If the power management control ECU detects that the engine or transaxle gear has seized, the power management control ECU will perform fail-safe control. Also, if a substance or object is preventing the engine or transaxle internal components from rotating, the power management control ECU will perform fail-safe control.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A0F-238 | Engine Failed to Start | Engine does not start even though it is being cranked (transaxle input malfunction [engine system]) | ·
Hybrid vehicle transaxle assembly ·
Transmission input damper assembly ·
Power management control ECU ·
Engine |
Does not come on | Master Warning Light:
Comes on |
If this DTC is output, the engine or transaxle gear may be seized. Be sure to check the level of the engine oil, automatic transmission fluid (ATF) and coolant before inspection.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A0F-238 only is output. | A |
| P0A1D (Hybrid Powertrain Control Module) is output. | B |
Turn the power switch off.
A
B
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Check that the shift lever is in the P position.
Lift up the vehicle.
Turn the crankshaft pulley using hand tools to check if the crankshaft can rotate smoothly.
Do not turn the power switch on (READY) while performing this inspection. Be sure to turn the power switch off before performing this inspection, to prevent the engine from starting.
Engine compression causes resistance when turning the crankshaft pulley. Check if the crankshaft rotates smoothly (or if it is locked) by manually applying sufficient torque to turn the crankshaft pulley. The torque required to turn the crankshaft pulley should be the same as for a known good vehicle of the same type.
The crankshaft rotates smoothly.
Lower the vehicle.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the power switch off.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the intelligent tester to the DLC3.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Data List / Generator (MG1) Rev, Engine Revolution.
| Tester Display |
|---|
| Engine Revolution |
| Generator(MG1) Rev |
Read the Data List.
While the READY indicator is on, fully depress the accelerator pedal for 10 seconds.
Generator (MG1) Rev increases to approximately 3.6 times that of Engine Revolution.
Refer to the graph for Data List confirmation of "Generator (MG1) Rev" and " Engine Revolution".
| Data List | ENGINE REV | MG1 REV |
|---|---|---|
| Reference Value | Approximately 1000 rpm | Approximately 3600 rpm |
| Approximately 1500 rpm | Approximately 5400 rpm | |
| Approximately 2500 rpm | Approximately 9000 rpm |
Turn the power switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the power switch on (READY).
Depress the brake pedal, move the shift lever to D, and release the brake pedal.
The wheels turn (the vehicle creeps forward).
Turn the power switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the intelligent tester to the DLC3.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Data List / Motor (MG2) Revolution, Generator (MG1) Rev, Engine Revolution.
| Tester Display |
|---|
| Engine Revolution |
| Motor(MG2) Revolution |
| Generator(MG1) Rev |
Read the Data List.
Move the shift lever to D.
Fully depress the accelerator pedal to accelerate the vehicle from a stop.
Perform this test only in an appropriate safe location, in accordance with all local laws.
The difference between Engine Revolution and 0.28 X Generator (MG1) Rev + 0.29 X Motor (MG2) Revolution is 500 rpm or more and it is maintained for 1 second.
Turn the power switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Lift up the vehicle.
Move the shift lever to N.
Turn the crankshaft pulley using hand tools to check if the crankshaft can rotate smoothly.
Do not turn the power switch on (READY) while performing this inspection. Be sure to turn the power switch off before performing this inspection, to prevent the engine from starting.
Engine compression causes resistance when turning the crankshaft pulley. Check if the crankshaft rotates smoothly (or if it is locked) by manually applying sufficient torque to turn the crankshaft pulley. The torque required to turn the crankshaft pulley should be the same as for a known good vehicle of the same type.
The crankshaft rotates smoothly.
Lower the vehicle.
| Proceed to |
|---|
| OK |
| NG |
OK
NG