The MG ECU located in the inverter with converter assembly monitors the generator inverter current sensors. P0A72 and P0A75 indicate malfunctions in the current sensors, and they do not indicate malfunctions in the high-voltage system.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A72-326 | Generator Phase V Current | Malfunction in generator inverter current sensor (phase V sub sensor) | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A72-328 | Generator Phase V Current | Malfunction in generator inverter current sensor (phase V main sensor) | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A72-333 | Generator Phase V Current | Malfunction in generator inverter current sensor (performance problem or open phase V) | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A72-515 | Generator Phase V Current | Malfunction in generator inverter current sensor (phase V main and sub sensors offset) | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A75-334 | Generator Phase W Current | Malfunction in generator inverter current sensor (phase W sub sensor) | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A75-336 | Generator Phase W Current | Malfunction in generator inverter current sensor (phase W main sensor) | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A75-341 | Generator Phase W Current | Malfunction in generator inverter current sensor (performance problem or open phase W) | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A75-516 | Generator Phase W Current | Malfunction in generator inverter current sensor (phase W main and sub sensors offset) | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A72 or P0A75 only is output. | A |
| P0A7A-203 is output. | B |
Turn the power switch off.
A
B
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0343-747)
| Proceed to |
|---|
| OK |
| NG |
OK
NG