Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.02–2016.05
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A1A-151  Generator Control Module  P0A1A-155  Generator Control Module  P0A1A-156  Generator Control Module  P0A1A-166  Generator Control Module  P0A1A-658  Generator Control Module  P0A1A-659  Generator Control Module  P0A1A-791  Generator Control Module  P0A1B-163  Drive Motor "A" Control Module  P0A1B-164  Drive Motor "A" Control Module  P0A1B-192  Drive Motor "A" Control Module  P0A1B-193  Drive Motor "A" Control Module  P0A1B-198  Drive Motor "A" Control Module  P0A1B-511  Drive Motor "A" Control Module  P0A1B-512  Drive Motor "A" Control Module  P0A1B-661  Drive Motor "A" Control Module  P0A1B-786  Drive Motor "A" Control Module  P0A1B-794  Drive Motor "A" Control Module  


DESCRIPTION

The MG ECU located in the inverter with converter assembly monitors its internal operation and it will set DTCs when it detects malfunctions. If any of the following DTCs are output, replace the inverter with converter assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A1A-151 Generator Control Module Run pulse signal cycle deviation or stop Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1A-155 Generator Control Module A/D converter error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1A-156 Generator Control Module CPU ROM-RAM error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1A-166 Generator Control Module R/D converter NM stop error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1A-658 Generator Control Module ALU error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1A-659 Generator Control Module Communication error (from MG1 to MG2) Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1A-791 Generator Control Module R/D converter communication error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-163 Drive Motor "A" Control Module IPM positive power source error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-164 Drive Motor "A" Control Module IPM negative power source error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-192 Drive Motor "A" Control Module A/D converter error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-193 Drive Motor "A" Control Module CPU ROM-RAM error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-198 Drive Motor "A" Control Module R/D converter NM stop error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-511 Drive Motor "A" Control Module Standard voltage for analog signal offset Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-512 Drive Motor "A" Control Module Standard voltage for analog signal offset Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-661 Drive Motor "A" Control Module Communication error (from MG2 to MG1) Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-786 Drive Motor "A" Control Module ALU error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-794 Drive Motor "A" Control Module R/D converter communication error Inverter with converter assembly Comes on Master Warning Light:
Comes on

PROCEDURE

1.REPLACE INVERTER WITH CONVERTER ASSEMBLY

NEXT

COMPLETED