The MG ECU located in the inverter with converter assembly monitors its internal operation and detects the following malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A1A-200 | Generator Control Module | The difference between the resolver angle for control and estimated resolver angle exceeds the allowable value. | ·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Wire harness or connector |
Comes on | Master Warning Light:
Comes on |
| P0A1A-792 | Generator Control Module | Resolver REF signal cycle error | ·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Wire harness or connector |
Comes on | Master Warning Light:
Comes on |
| P0A1A-793 | Generator Control Module | Resolver REF signal oscillation stop error | ·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Wire harness or connector |
Comes on | Master Warning Light:
Comes on |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A1A-200, 792 or 793 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
Turn the power switch off.
A
B
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0343-747)
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector E1 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E1-1 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| E1-7 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-2 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| E1-8 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-3 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| E1-9 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector E1 from the inverter with converter assembly.
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E1-1 (GRF) - E1-7 (GRFG) | Power switch off | 4.2 to 12.5 Ω |
| E1-2 (GSN) - E1-8 (GSNG) | Power switch off | 9.8 to 20.1 Ω |
| E1-3 (GCS) - E1-9 (GCSG) | Power switch off | 9.8 to 20.1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E1-1 (GRF) or E1-7 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-2 (GSN) or E1-8 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-3 (GCS) or E1-9 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector E1 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E1-4 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| E1-11 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-5 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| E1-12 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| E1-6 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| E1-13 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector E1 from the inverter with converter assembly.
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E1-4 (MRF) - E1-11 (MRFG) | Power switch off | 4.2 to 12.5 Ω |
| E1-5 (MSN) - E1-12 (MSNG) | Power switch off | 9.8 to 20.1 Ω |
| E1-6 (MCS) - E1-13 (MCSG) | Power switch off | 9.8 to 20.1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E1-4 (MRF) or E1-11 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-5 (MSN) or E1-12 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-6 (MCS) or E1-13 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the connection of the generator resolver connector.
The connector is connected securely and there are no contact problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the connection of the motor resolver connector.
The connector is connected securely and there are no contact problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the connection of the generator resolver connector.
The connector is connected securely and there are no contact problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector E1 from the inverter with converter assembly.
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| *a | Front view of wire harness connector
(to Generator Resolver) |
*b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E1-1 (GRF) - E13-1 (GRF) | Power switch off | Below 1 Ω |
| E1-7 (GRFG) - E13-5 (GRFG) | Power switch off | Below 1 Ω |
| E1-2 (GSN) - E13-2 (GSN) | Power switch off | Below 1 Ω |
| E1-8 (GSNG) - E13-6 (GSNG) | Power switch off | Below 1 Ω |
| E1-3 (GCS) - E13-3 (GCS) | Power switch off | Below 1 Ω |
| E1-9 (GCSG) - E13-7 (GCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E1-1 (GRF) or E13-1 (GRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-7 (GRFG) or E13-5 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-2 (GSN) or E13-2 (GSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-8 (GSNG) or E13-6 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-3 (GCS) or E13-3 (GCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-9 (GCSG) or E13-7 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.
Connect the generator resolver connector.
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the connection of the motor resolver connector.
The connector is connected securely and there are no contact problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector E1 from the inverter with converter assembly.
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| *a | Front view of wire harness connector
(to Motor Resolver) |
*b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E1-4 (MRF) - E12-1 (MRF) | Power switch off | Below 1 Ω |
| E1-11 (MRFG) - E12-4 (MRFG) | Power switch off | Below 1 Ω |
| E1-5 (MSN) - E12-2 (MSN) | Power switch off | Below 1 Ω |
| E1-12 (MSNG) - E12-5 (MSNG) | Power switch off | Below 1 Ω |
| E1-6 (MCS) - E12-3 (MCS) | Power switch off | Below 1 Ω |
| E1-13 (MCSG) - E12-6 (MCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E1-4 (MRF) or E12-1 (MRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-11 (MRFG) or E12-4 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-5 (MSN) or E12-2 (MSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-12 (MSNG) or E12-5 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-6 (MCS) or E12-3 (MCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| E1-13 (MCSG) or E12-6 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.
Connect the motor resolver connector.
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG