Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0AC0-817  Hybrid Battery Pack Current Sensor Circuit Range / Performance  


DESCRIPTION

The battery current sensor, which is located in the hybrid battery junction block assembly on the positive side of the HV battery, detects the amperage that flows to and from the HV battery. The battery smart unit receives a voltage of between 0 and 5 V that is in proportion to the amperage flowing in the cable. This voltage goes into the IB terminal from the battery current sensor. A battery current sensor output voltage below 2.5 V indicates that the HV battery is being charged, and a voltage above 2.5 V indicates that the HV battery is being discharged. The power management control ECU determines the amount of either charge or discharge amperage that is being received by the HV battery based on the signals that are input to terminal IB of the battery smart unit from the battery current sensor. The power management control ECU also calculates the SOC (state of charge) of the HV battery based on the accumulated amperage.

A260083E02
0.167,0.031 0.75,0.365 0.583,0.333 10 Charging Current 1.063,0.031 1.844,0.365 0.781,0.333 10 Discharging Current 1.125,1.083 2.104,1.688 0.979,0.604 10 Battery Current Sensor 2.031,0.583 3.208,0.76 1.177,0.177 10 Battery Smart Unit 2.375,1.573 2.635,1.75 0.26,0.177 10 VIB 2.375,1.927 2.635,2.104 0.26,0.177 10 GIB 2.375,1.74 2.542,1.917 0.167,0.177 10 IB 3.917,0.948 4.146,1.115 0.229,0.167 10 4.5 3.917,1.688 4.146,1.854 0.229,0.167 10 2.5 3.917,2.417 4.146,2.583 0.229,0.167 10 0.5 4.219,2.719 4.521,2.875 0.302,0.156 10 -200 6.698,2.719 6.958,2.875 0.26,0.156 10 200 5.552,2.719 5.667,2.875 0.115,0.156 10 0 4.896,3.271 6.333,3.458 1.438,0.188 10 HV Battery Current (A) 3.479,0.219 5.885,0.552 2.406,0.333 10 Battery Current Sensor Output Voltage 3.948,0.563 4.333,0.802 0.385,0.24 10 (V) 4.188,3.135 4.802,3.375 0.615,0.24 10 Charge 6.438,3.146 7.125,3.344 0.688,0.198 10 Discharge


DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0AC0-817 Hybrid Battery Pack Current Sensor Circuit Range / Performance HV battery current sensor performance problem
·

Hybrid battery junction block assembly

·

Battery smart unit


Comes on Master Warning Light:
Comes on

PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
P0AC0-817 only is output. A
P0AFC-123 is output. B



e.

Turn the power switch off.



A

2.REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY

B

2.REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY

NEXT

3.CLEAR DTC
3.CLEAR DTC
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Read and record the DTCs and freeze frame data.


e.

Clear DTCs and freeze frame data.

Powertrain > Hybrid Control > Clear DTCs
50002 236

f.

Turn the power switch off.

Result:
Proceed to
NEXT




NEXT

4.PERFORM ROAD TEST
4.PERFORM ROAD TEST
Result:
Proceed to
NEXT



NEXT

5.CHECK DTC OUTPUT (HYBRID CONTROL)
5.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
P0AC0-817 is not output. A
P0AC0-817 is output again. B



e.

Turn the power switch off.



A

COMPLETED

B