Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.02–2015.04
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0340-886  Camshaft Position Sensor "A" Circuit  


DESCRIPTION

The power management control ECU compares the engine speed sent from the ECM via CAN communication and the engine speed that is indicated by pulses sent from the ECM. If the pulse input is not normal, the power management control ECU sets this DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0340-886 Camshaft Position Sensor "A" Circuit Malfunction in the engine speed sensor (GI signal) circuit
·

Wire harness or connector

·

Camshaft position sensor

·

Inverter with converter assembly

·

ECM

·

Power management control ECU


Does not come on Master Warning Light: Comes on

WIRING DIAGRAM

A260350E03
2.667,5.271 3.094,5.448 0.427,0.177 10 false A14 2.677,5.417 4.844,5.594 2.167,0.177 10 false Inverter with Converter Assembly 3.865,4.344 4.083,4.51 0.219,0.167 10 false GI 4.083,4.333 4.302,4.5 0.219,0.167 10 false 1 2.979,4.75 3.406,4.917 0.427,0.167 10 false GND1 2.76,4.656 2.979,4.823 0.219,0.167 10 false 10 2.979,2.854 3.385,3.031 0.406,0.177 10 false ECM 2.292,2.188 2.552,2.385 0.26,0.198 10 false E1 2,2 2.219,2.177 0.219,0.177 10 false 16 0.063,1.646 1.771,1.958 1.708,0.313 10 false Camshaft Position Sensor 2.781,1.302 3.021,1.542 0.24,0.24 10 false IC 4.219,1.01 4.417,1.188 0.198,0.177 10 false 60 3.792,1.104 4.125,1.281 0.333,0.177 10 false G2O 5.365,1.229 5.656,1.385 0.292,0.156 10 false A38 5.406,1.021 5.656,1.208 0.25,0.188 10 false 16 5.448,2 5.698,2.188 0.25,0.188 10 false 6 5.427,2.188 5.594,2.344 0.167,0.156 10 false I3 5.677,1.115 5.885,1.292 0.208,0.177 10 false GI 5.708,2.198 5.917,2.375 0.208,0.177 10 false E1 5.583,2.844 6.823,3.208 1.24,0.365 10 false Power Management Control ECU 3.635,4.698 4.063,4.865 0.427,0.167 10 false DRN5 4.104,4.615 4.323,4.781 0.219,0.167 10 false 2 4.177,1.219 4.49,1.406 0.313,0.188 10 false A25 1.969,2.188 2.281,2.385 0.313,0.198 10 false E28

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
P0340-886 only is output. A
P0343-747 is also output. B



e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)

B

7.CHECK HARNESS AND CONNECTOR (ECM - POWER MANAGEMENT CONTROL ECU, INVERTER WITH CONVERTER)
2.CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)
a.
A258441

Check the connector connections and contact pressure of the relevant terminals for the ECM connectors.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

NOTICE:

Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.


OK:

The connectors are connected securely and there are no contact pressure problems.


HINT:

When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



Result:
Proceed to
OK
NG



OK

3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

NG

CONNECT SECURELY

3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)
a.
A259379

Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

The connectors are connected securely and there are no contact pressure problems.



Result:
Proceed to
OK
NG



OK

4.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)

NG

CONNECT SECURELY

4.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)
a.

Connect an oscilloscope between the power management control ECU terminals specified in the table below.


b.

Turn the power switch on (READY).


c.
A216633C09
0.635,0.573 1.052,0.813 0.417,0.24 1.875,0.573 2.292,0.813 0.417,0.24 0.646,1.365 0.375,1.854 true 1.823,1.302 1.792,1.854 true 0.125,0.146 0.344,0.365 0.219,0.219 10 false *a 0.271,1.854 0.448,2.01 0.177,0.156 10 false GI 1.677,1.854 1.885,2.021 0.208,0.167 10 false E1 2.99,3.542 3.354,3.719 0.365,0.177 10 false GND 0.719,0.615 1.073,0.823 0.354,0.208 10 false A38 2.042,0.615 2.313,0.781 0.271,0.167 10 false I3
*a Component with harness connected
(Power Management Control ECU)


Measure the waveform.

Item Content
Terminal A38-16 (GI) - I3-6 (E1)
Equipment Setting 5 V/DIV., 20 ms./DIV.
Condition Power switch on (READY), with engine running

Result:
Result Proceed to
Normal A
Waveform is flat, and is stuck on the +B side. B
Waveform is flat, and is stuck on the GND side. C



d.

Turn the power switch off.



A

5.CHECK FOR INTERMITTENT PROBLEMS

B

6.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU)

C

7.CHECK HARNESS AND CONNECTOR (ECM - POWER MANAGEMENT CONTROL ECU, INVERTER WITH CONVERTER)
5.CHECK FOR INTERMITTENT PROBLEMS

OK

NG

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA

6.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A25 from the ECM.


c.

Disconnect connector A14 from the inverter with converter assembly.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.
A259780C04
0.427,1.01 0.844,1.25 0.417,0.24 2.594,1.448 2.448,1.917 true 0.125,0.073 0.406,0.25 0.281,0.177 10 false *a 2.271,1.938 2.625,2.115 0.354,0.177 10 false G2O 0.5,1.063 0.771,1.229 0.271,0.167 10 false A25
*a Front view of wire harness connector
(to ECM)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A25-60 (G2O) - Body ground Power switch on (IG) 11 to 14 V


NOTICE:

Turning the power switch on (IG) with the ECM connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal.


i.

Connect the inverter with converter assembly connector.


j.

Connect the ECM connector.

Result:
Proceed to
OK
NG




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (ECM - POWER MANAGEMENT CONTROL ECU, INVERTER WITH CONVERTER)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A25 from the ECM.


c.

Disconnect connector A38 from the power management control ECU.


d.

Disconnect connector A14 from the inverter with converter assembly.


e.

Connect the cable to the negative (-) auxiliary battery terminal.


f.

Turn the power switch on (IG).


g.
A259781C05
0.271,1.229 0.688,1.469 0.417,0.24 1.26,3.781 1.677,4.021 0.417,0.24 2.354,1.635 2.583,2.188 true 0.75,3.927 0.521,4.177 true 0.115,0.156 0.385,0.396 0.271,0.24 10 false *a 0.115,2.208 0.385,2.448 0.271,0.24 10 false *b 2.458,2.208 2.833,2.417 0.375,0.208 10 false G2O 0.385,4.188 0.635,4.354 0.25,0.167 10 false GI 0.354,1.281 0.667,1.479 0.313,0.198 10 false A25 1.333,3.823 1.677,4.031 0.344,0.208 10 false A38
*a Front view of wire harness connector
(to ECM)
*b Rear view of wire harness connector
(to Power Management Control ECU)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A25-60 (G2O) or A38-16 (GI) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector, power management control ECU connector and ECM connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



h.

Turn the power switch off.


i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A25-60 (G2O) or A38-16 (GI)- Body ground Power switch off 10 kΩ or higher



j.

Disconnect the cable from the negative (-) auxiliary battery terminal.


k.

Connect the ECM connector.


l.

Connect the power management control ECU connector.


m.

Connect the inverter with converter assembly connector.

Result:
Proceed to
OK
NG




OK

8.CHECK POWER MANAGEMENT CONTROL ECU

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK POWER MANAGEMENT CONTROL ECU
a.

Disconnect all the connectors from the power management control ECU.


b.
A204442C25
0.615,1.073 1.031,1.313 0.417,0.24 1.844,1.073 2.26,1.313 0.417,0.24 0.635,1.917 0.844,2.365 true 1.823,1.833 2.073,2.344 true 0.698,1.115 0.969,1.281 0.271,0.167 10 false A38 2,1.115 2.271,1.281 0.271,0.167 10 false I3 0.177,0.229 0.365,0.417 0.188,0.188 10 false *a 0.813,2.375 1,2.563 0.188,0.188 10 false GI 2.031,2.375 2.219,2.563 0.188,0.188 10 false E1
*a Component without harness connected
(Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A38-16 (GI) - I3-6 (E1) Power switch off 10 kΩ or higher



c.

Connect the power management control ECU connectors.

Result:
Proceed to
OK
NG




OK

9.CHECK INVERTER WITH CONVERTER ASSEMBLY

NG

9.CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A14 from the inverter with converter assembly.


c.
A258450C07
1.167,1.677 1.583,1.917 0.417,0.24 1.01,0.958 1.167,0.25 true 1.167,0.25 1.292,0.25 true 1.844,0.906 2,0.25 true 2,0.25 2.125,0.25 true 0.135,0.083 0.417,0.25 0.281,0.167 10 false *a 1.26,1.729 1.531,1.896 0.271,0.167 10 false A14 1.333,0.177 1.76,0.354 0.427,0.177 10 false GND1 2.167,0.177 2.396,0.365 0.229,0.188 10 false GI
*a Component without harness connected
(Inverter with Converter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A14-1 (GI) - A14-10 (GND1) Power switch off 10 kΩ or higher



d.

Connect the inverter with converter assembly connector.

Result:
Proceed to
OK
NG




OK

NG

REPLACE INVERTER WITH CONVERTER ASSEMBLY