Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.02–2015.04
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0C76-523  Hybrid Battery System Discharge Time Too Long  


DESCRIPTION

Refer to the description for DTC P0A78-266.

See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A78-266

HINT:

When the power switch is turned off, the MG ECU applies current to MG2 in a way that does not generate torque, in order to discharge the residual voltage in the inverter. When the hybrid system is normal, the VH value is almost 0 V after discharge. This DTC will be stored if the VH value is more than the specified value after discharge.


A111758E10
4,2.115 4.781,1.906 false 3.99,1.729 4.76,1.531 false 2.031,0.698 2.208,0.854 0.177,0.156 10 false IG 2.635,0.583 2.875,0.74 0.24,0.156 10 false ON 3.063,0.802 3.365,0.958 0.302,0.156 10 false OFF 2,1.333 2.219,1.49 0.219,0.156 10 false VH 4.854,1.458 5.49,1.625 0.635,0.167 10 false Abnormal 3.208,2.344 4.313,2.51 1.104,0.167 10 false During Discharge 4.875,1.833 5.365,2 0.49,0.167 10 false Normal

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0C76-523 Hybrid Battery System Discharge Time Too Long Inverter voltage (VH) sensor offset malfunction
·

Inverter with converter assembly

·

Wire harness or connector

·

Power management control ECU


Does not come on Master Warning Light:
Comes on

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

See pageGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 236
Result:
Result Proceed to
Only P0C76-523 is output or P0C76-523 and DTCs other than the ones in the table below are also output. A
Any of the following DTCs are also output. B


DTC No. Relevant Diagnosis
P0A1A-151, 155, 156, 200, 658, 659, 791, 792, 793 Generator Control Module
P0A1B-163, 164, 168, 193, 511, 661, 786, 794, 795, 796 Drive Motor "A" Control Module
P0A1D-148 Hybrid Powertrain Control Module
P0A3F-243 Drive Motor "A" Position Sensor Circuit
P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
P0A41-245 Drive Motor "A" Position Sensor Circuit Low
P0A4B-253 Generator Position Sensor Circuit
P0A4C-513 Generator Position Sensor Circuit Range/Performance
P0A4D-255 Generator Position Sensor Circuit Low
P0A78-266, 267 Drive Motor "A" Inverter Performance
P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
P0AE7-224 Hybrid Battery Precharge Contactor Control Circuit High
P2511-149 ECM/PCM Power Relay Sensor Circuit Intermittent
P324E-788 MG-ECU Power Relay Intermittent Circuit
U0110 (all INF codes)*1 Lost Communication with Drive Motor Control Module "A"

HINT:
·

*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

·

P0C76-523 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.




e.

Turn the power switch off.



A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 236
Result:
Result Proceed to
Any of the following DTCs are also output. A
Only P0C76-523 is output or P0C76-523 and DTCs other than the ones in the table below are also output. B


DTC No. Relevant Diagnosis
P0A78-306 Drive Motor "A" Inverter Performance
P0A7A-344 Generator Inverter Performance
P0A90-251, 509 Drive Motor "A" Performance
P0A92-261, 521 Hybrid Generator Performance

HINT:

When the DTCs listed in the table above are also output, there may be a short between the HSDN (MG shut down signal) circuit and power circuit.



e.

Turn the power switch off.



A

3.CHECK POWER MANAGEMENT CONTROL ECU

B

3.CHECK POWER MANAGEMENT CONTROL ECU
a.

Turn the power switch on (IG).


b.
A252924C93
1.177,2.792 1.573,3.115 0.396,0.323 1.906,2.813 2.292,3.115 0.385,0.302 1.521,1.917 1.125,2.438 true 1.823,1.729 2.198,2.469 true 0.271,0.208 0.438,0.365 0.167,0.156 10 false *a 1.25,2.823 1.521,2.99 0.271,0.167 10 false A39 2.031,2.844 2.302,3.01 0.271,0.167 10 false I3 0.885,2.448 1.302,2.635 0.417,0.188 10 false HSDN 2.188,2.5 2.552,2.698 0.365,0.198 10 false E1
*a Component with harness connected
(Power Management Control ECU)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A39-31 (HSDN) - I3-6 (E1) Power switch on (IG) Below 4.5 V



c.

Turn the power switch off.


Result:
Proceed to
OK
NG



OK

NG

4.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
4.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A14 from the inverter with converter assembly.


c.

Disconnect connector A39 from the power management control ECU.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A14-40 (HSDN) or A39-31 (HSDN) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.


A306421C01
1.167,0.563 1.615,0.875 0.448,0.313 4.094,1.583 4.542,1.896 0.448,0.313 1.792,1.552 2.146,2.167 true 1.667,1.573 1.792,2.156 true 1.521,1.542 1.24,2.135 true 5.333,1.74 6.198,2.406 true 5.25,1.74 5.75,2.385 true 5.198,1.938 5.24,2.396 true 4.927,1.75 4.438,2.375 true 4.99,1.74 4.885,2.385 true 0.365,0.448 0.667,0.708 0.302,0.26 10 false *a 3.719,0.271 4.021,0.531 0.302,0.26 10 false *b 2.104,2.198 2.448,2.469 0.344,0.271 10 false +B2 1.698,2.198 1.979,2.448 0.281,0.25 10 false +B 1.042,2.198 1.479,2.448 0.438,0.25 10 false HSDN 1.26,0.646 1.583,0.865 0.323,0.219 10 false A14 4.208,1.625 4.531,1.844 0.323,0.219 10 false A39 6.115,2.427 6.458,2.698 0.344,0.271 10 false IG2 5.615,2.427 5.958,2.698 0.344,0.271 10 false IG2D 5.125,2.417 5.583,2.719 0.458,0.302 10 false HSDN 4.729,2.427 5.073,2.698 0.344,0.271 10 false +B1 4.219,2.427 4.646,2.688 0.427,0.26 10 false MREL
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Rear view of wire harness connector
(to Power Management Control ECU)



g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal.


i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A39-31 (HSDN) - A39-1 (IG2) Power switch off 10 kΩ or higher
A39-31 (HSDN) - A39-2 (IG2D) Power switch off 10 kΩ or higher
A39-31 (HSDN) - A39-5 (+B1) Power switch off 10 kΩ or higher
A39-31 (HSDN) - A39-6 (MREL) Power switch off 10 kΩ or higher
A14-40 (HSDN) - A14-30 (+B) Power switch off 10 kΩ or higher
A14-40 (HSDN) - A14-31 (+B2) Power switch off 10 kΩ or higher



j.

Connect the inverter with converter assembly connector.


k.

Connect the power management control ECU connector.


Result:
Proceed to
OK
NG



OK

5.CHECK INVERTER WITH CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A14 from the inverter with converter assembly.


c.
A258450C09
1.198,0.177 1.615,0.448 0.417,0.271 1.729,1.75 1.167,1.198 true 1.021,1.198 1.125,1.719 true 0.906,1.198 0.656,1.708 true 0.135,0.104 0.417,0.271 0.281,0.167 10 false *a 1.281,0.229 1.583,0.438 0.302,0.208 10 false A14 1.042,1.76 1.375,2.063 0.333,0.302 10 false +B 1.635,1.771 2.135,2.063 0.5,0.292 10 false HSDN 0.51,1.771 0.885,2.042 0.375,0.271 10 false +B2
*a Component without harness connected
(Inverter with Converter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A14-40 (HSDN) - A14-30 (+B) Power switch off 5 kΩ or higher
A14-40 (HSDN) - A14-31 (+B2) Power switch off 5 kΩ or higher



d.

Connect the inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

NG