Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074886 HYBRID BATTERY SYSTEM D

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  SYSTEM DESCRIPTION  


BATTERY SMART UNIT CONTROL


·

The battery smart unit converts the HV battery condition signals (voltage, current, and temperature), which are needed to determine the charging or discharging values that are calculated by the power management control ECU into digital signals, and transmits them to the power management control ECU via serial communication.

·

A leakage detection circuit is provided in the battery smart unit in order to detect any leakage from the HV battery. Furthermore, the battery smart unit detects the voltage of the cooling fan, which is needed by the power management control ECU to effect cooling fan control. The battery smart unit also converts these signals into digital signals and transmits them to the power management control ECU via serial communication.


A240886
5,2.688 5.417,3.719 false 5.802,1.156 6.896,1.531 1.094,0.375 10 false Battery Cooling Blower 5.563,2.563 6.906,3.01 1.344,0.448 10 false Power Management Control ECU 3.229,2.083 3.594,2.344 0.365,0.26 10 false CPU 2.427,3.198 3.99,3.531 1.563,0.333 10 false Voltage Detection Circuit 2.427,3.865 4.031,4.167 1.604,0.302 10 false Leakage Detection Circuit 0.688,2.698 1.427,2.969 0.74,0.271 10 false HV Battery 0.625,3.135 1.552,3.479 0.927,0.344 10 false Temperature Sensor Signal 0.552,2.948 0.646,3.125 0.094,0.177 10 false . 0.625,3.76 1.167,4.104 0.542,0.344 10 false Voltage 0.542,3.552 0.635,3.729 0.094,0.177 10 false . 0.615,1.906 1.635,2.219 1.021,0.313 10 false Current Sensor 2.813,0.875 4.021,1.271 1.208,0.396 10 false Battery Smart Unit 4.896,3.76 6.302,4.042 1.406,0.281 10 false Serial Communication