Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › COOLANT(for Inverter)
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074887 COOLANT(for Inverter) A

HYBRID / BATTERY CONTROL  COOLANT(for Inverter)  REPLACEMENT  


PROCEDURE

Hide 1.DRAIN COOLANT (for Inverter)

NOTICE:
·

Do not reuse the drained coolant because it may contain foreign objects.

·

Collect the drained coolant and measure its volume to establish a benchmark. When adding coolant, make sure to add more coolant than the measured amount.



a.

Remove the reserve tank cap.

CAUTION:

To avoid the danger of being burned, do not remove the reserve tank cap while the coolant for the inverter is still hot.



b.
A258732

Using a hexagon wrench (10 mm), remove the drain plug indicated in the illustration and drain the coolant.

CAUTION:

Use caution when handling coolant immediately after driving or in summer because it may be hot.



c.

Install the plug with a new gasket.

Torque:
39 N*m (398 kgf*cm, 29 ft.*lbf)


Hide 2.ADD COOLANT (for Inverter)

NOTICE:
·

Do not reuse the drained coolant because it may contain foreign objects.

·

If the vehicle is driven with air in the inverter cooling system, damage may occur and the following DTCs may be set.

DTC Code Detection Item
P0A01-725 Motor Electronics Coolant Temperature Sensor Circuit Range / Performance
P0A01-726 Motor Electronics Coolant Temperature Sensor Circuit Intermittent
P0A08-264 DC / DC Converter Status Circuit
P0A78-284 Drive Motor "A" Inverter Performance
P0A78-286 Drive Motor "A" Inverter Performance
P0A7A-322 Generator Inverter Performance
P0A7A-324 Generator Inverter Performance
P0A93-346 Inverter Cooling System Performance
P0A94-553 DC / DC Converter Performance
P0A94-557 DC / DC Converter Performance
P0AEE-276 Drive Motor Inverter Temperature Sensor "A" Circuit Intermittent / Erratic
P0AEE-277 Motor Inverter Temperature Sensor "A" Circuit Range / Performance
P0BD0-314 Generator Inverter Temperature Sensor Circuit Range / Erratic
P0BCD-315 Generator Inverter Temperature Sensor Circuit Range / Performance
P0C3C-625 DC / DC Converter Temperature Sensor "A" Intermittent / Erratic
P0C39-626 DC / DC Converter Temperature Sensor "A" Range / Performance
P0C41-627 DC / DC Converter Temperature Sensor "B" Intermittent / Erratic
P0C3E-628 DC / DC Converter Temperature Sensor "B" Range / Performance
P0C73-776 Motor Electronics Coolant Pump "A" Control Performance



a.
A258733

Slowly pour coolant into the reserve tank until it reaches the FULL line.

Coolant quantity:

3.2 liters (3.4 US qts, 2.8 Imp. qts.)


NOTICE:

To prevent foreign matter such as dust or dirt from entering the cooling system, make sure to confirm that the container used to add coolant is clean and free of foreign matter such as dust or dirt.



b.

When using the intelligent tester:

i.

Connect the intelligent tester to the DLC3.


ii.

Turn the power switch on (IG).


iii.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

Powertrain > Hybrid Control > Active Test
Tester Display
Activate the Water Pump
50004 236 9

iv.

Keep the coolant at the FULL line in the reserve tank to compensate for the drop in coolant level when the air bleeds.

Standard:

Air bleeding from the inverter cooling system is completed when the noise made by the inverter water pump assembly becomes smaller and the circulation of coolant in the reserve tank improves.


HINT:
·

If free spinning of the inverter water pump is detected for approximately 5 seconds, failsafe control will be activated to suspend the operation of the pump for approximately 15 seconds and resume operation for approximately 4 seconds repeatedly. Operation of the inverter water pump will return to normal if coolant is added.

·

Loud noise made by the inverter water pump assembly and poor circulation of coolant in the reserve tank indicates that there is air in the cooling system.

·

Loud noise made by the water pump and poor circulation of coolant in the reserve tank indicates that there is air in the cooling system.





c.

When not using the intelligent tester:

i.

Turn the power switch on (READY).[*1]


ii.

Turn the power switch off and add coolant to the FULL line because the coolant level drops as the air bleeds.[*2]

NOTICE:
·

Be sure to turn the power switch off before adding SLLC.

·

Do not work on the components in the engine compartment while the vehicle is in the READY-on state because the engine is in intermittent operation.




iii.

Repeat steps [*1] and [*2] until air bleeding from the cooling system is completed.

Standard:

Air bleeding from the inverter cooling system is completed when the noise made by the inverter water pump assembly becomes smaller and the circulation of coolant in the reserve tank improves.


HINT:

Loud noise made by the water pump and poor circulation of coolant in the reserve tank indicates that there is air in the cooling system.




d.

After the air is completely bled from the cooling system, tighten the reserve tank cap.


e.
A258733

Add coolant to the FULL line of the reserve tank.