85924
1.INSPECT IGNITION CONTROL RELAY (IGCT)
| *1 | Ignition Control Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage is not applied across terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Auxiliary battery voltage is applied across terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the relay.
G9020E
2.INSPECT HYBRID WATER PUMP RELAY (INV W/PMP)
| *1 | Hybrid Water Pump Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage is not applied across terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Auxiliary battery voltage is applied across terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the relay.