G92Z0
1.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
Inspect SMRB.
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-1 (+) - Q2-1 (CBI) | Auxiliary battery voltage is not applied between terminals O9-1 (SMRB) and O9-2 (GND) | 10 kΩ or higher |
| A-1 (+) - Q2-1 (CBI) | Auxiliary battery voltage is applied between terminals O9-1 (SMRB) and O9-2(GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O9-1 (SMRB) - O9-2 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
If the result is not as specified, replace the hybrid battery junction block assembly or electric vehicle fuse.
Inspect SMRG.
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| q1-1(-) - Q3- 1(CEI) | Auxiliary battery voltage is not applied between terminals O9-3(SMRG) and O9-2(GND) | 10 kΩ or higher |
| q1-1(-) - Q3- 1(CEI) | Auxiliary battery voltage is applied between terminals O9-3(SMRG) and O9-2(GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O9-3(SMRG) - O9-2(GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
If the result is not as specified, replace the hybrid battery junction block assembly.
Inspect SMRP.
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Q3-1 (CEI) - q1-1 (-)) | Auxiliary battery voltage is not applied between terminals O9-4(SMRP) and O9-2(GND) | 10 kΩ or higher |
| Q3-1 (CEI) - q1-1 (-)) | Auxiliary battery voltage is applied between terminals O9-4(SMRP) and O9-2(GND) | 28.5 to 31.5 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O9-4(SMRP) and O9-2(GND) | -40 to 80°C (-40 to 176°F) | 112 to 274 Ω |
If the result is not as specified, replace the hybrid battery junction block assembly.