HYBRID / BATTERY CONTROL  HV RELAY ASSEMBLY  INSPECTION  


PROCEDURE

Hide G92Z0 1.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

a.

Inspect SMRB.

i.
A283669
0.927,0.323 1.198,0.583 0.271,0.26 2.875,0.802 3.104,1.031 0.229,0.229 0.396,2.354 0.698,2.594 0.302,0.24 0.865,2.927 1.188,2.552 false 1.385,2.552 1.74,2.896 false 0.469,0.688 0.75,0.792 false 2.771,1.208 3.063,1.333 false 0.958,0.365 1.323,0.677 0.365,0.313 10 false Q2 2.948,0.854 3.104,1.052 0.156,0.198 10 false A 0.448,2.396 0.823,2.74 0.375,0.344 10 false O9 1.583,2.948 2.208,3.271 0.625,0.323 10 false SMRB 0.729,2.969 1.198,3.25 0.469,0.281 10 false GND 0.135,0.115 0.469,0.396 0.333,0.281 10 false *a 0.219,0.573 0.646,0.854 0.427,0.281 10 false CBI 3.115,1.271 3.271,1.469 0.156,0.198 10 false +
*a Component without harness connected
(Hybrid Battery Junction Block Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A-1 (+) - Q2-1 (CBI) Auxiliary battery voltage is not applied between terminals O9-1 (SMRB) and O9-2 (GND) 10 kΩ or higher
A-1 (+) - Q2-1 (CBI) Auxiliary battery voltage is applied between terminals O9-1 (SMRB) and O9-2(GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
O9-1 (SMRB) - O9-2 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω


If the result is not as specified, replace the hybrid battery junction block assembly or electric vehicle fuse.



b.

Inspect SMRG.

i.
A283670
0.292,0.76 0.563,1.031 0.271,0.271 2.865,1.635 3.135,1.875 0.271,0.24 0.323,2.344 0.635,2.615 0.313,0.271 0.719,3.021 1.042,2.552 false 1.25,2.552 1.677,3.052 false 0.802,0.938 1.167,0.51 true 2.719,1.417 3.021,1.021 true 0.115,0.104 0.469,0.448 0.354,0.344 10 false *a 0.344,0.813 0.667,1.115 0.323,0.302 10 false Q3 2.917,1.656 3.281,1.948 0.365,0.292 10 false q1 0.396,2.396 0.729,2.729 0.333,0.333 10 false O9 0.51,3.063 1.104,3.385 0.594,0.323 10 false SMRG 1.594,3.094 2.094,3.365 0.5,0.271 10 false GND 3.063,0.875 3.229,1.073 0.167,0.198 10 false - 1.198,0.354 1.792,0.677 0.594,0.323 10 false CEI
*a Component without harness connected
(Hybrid Battery Junction Block Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
q1-1(-) - Q3- 1(CEI) Auxiliary battery voltage is not applied between terminals O9-3(SMRG) and O9-2(GND) 10 kΩ or higher
q1-1(-) - Q3- 1(CEI) Auxiliary battery voltage is applied between terminals O9-3(SMRG) and O9-2(GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
O9-3(SMRG) - O9-2(GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω


If the result is not as specified, replace the hybrid battery junction block assembly.



c.

Inspect SMRP.

i.
A283670
0.292,0.76 0.563,1.031 0.271,0.271 2.865,1.635 3.135,1.875 0.271,0.24 0.323,2.344 0.635,2.615 0.313,0.271 0.635,3.052 0.917,2.552 false 1.25,2.552 1.677,3.052 false 0.813,0.927 1.063,0.49 true 2.719,1.417 3.021,1.042 true 0.115,0.104 0.469,0.448 0.354,0.344 10 false *a 0.344,0.813 0.667,1.115 0.323,0.302 10 false Q3 2.917,1.656 3.281,1.948 0.365,0.292 10 false q1 0.396,2.406 0.729,2.74 0.333,0.333 10 false O9 0.469,3.083 0.948,3.302 0.479,0.219 10 false SMRP 1.594,3.094 2.094,3.365 0.5,0.271 10 false GND 1.094,0.375 1.427,0.583 0.333,0.208 10 false CEI 3.063,0.927 3.292,1.167 0.229,0.24 10 false -
*a Component without harness connected
(Hybrid Battery Junction Block Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Q3-1 (CEI) - q1-1 (-)) Auxiliary battery voltage is not applied between terminals O9-4(SMRP) and O9-2(GND) 10 kΩ or higher
Q3-1 (CEI) - q1-1 (-)) Auxiliary battery voltage is applied between terminals O9-4(SMRP) and O9-2(GND) 28.5 to 31.5 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
O9-4(SMRP) and O9-2(GND) -40 to 80°C (-40 to 176°F) 112 to 274 Ω


If the result is not as specified, replace the hybrid battery junction block assembly.