Home › Engine / Hybrid System › 2AR-FXE COOLING › THERMOSTAT
RM2040EQ _51 Engine / Hybrid System _014697 2AR-FXE COOLING _0074931 THERMOSTAT G

2AR-FXE COOLING  THERMOSTAT  INSPECTION  


PROCEDURE

Hide 16031 1.INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY

A259353

HINT:

The valve opening temperature is inscribed on the water inlet with thermostat sub-assembly.


a.

Immerse the water inlet with thermostat sub-assembly in water and then gradually heat the water.


b.

Check the valve opening temperature of the water inlet with thermostat sub-assembly.

Valve opening temperature:

80 to 84°C (176 to 183°F)


HINT:

If the valve opening temperature is not as specified, replace the water inlet with thermostat sub-assembly.



c.
A259354
2.583,1.604 2.896,1.76 0.313,0.156 10 *a
*a Valve Lift


Check the valve lift.

Valve lift:

10 to 11.3 mm (0.394 to 0.445 in.) at 95°C (203°F)


HINT:

If the valve lift is not as specified, replace the water inlet with thermostat sub-assembly.



d.

Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at low temperatures (below 77°C (171°F)).

HINT:

If it is not fully closed, replace the water inlet with thermostat sub-assembly.