89611
1.INSPECT POWER SWITCH
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| I58-5 (SS1) - I58-6 (AGND) | Not pushed | 10 kΩ or higher |
| I58-1 (SS2) - I58-6 (AGND) | ||
| I58-5 (SS1) - I58-6 (AGND) | Pushed | Below 1 Ω |
| I58-1 (SS2) - I58-6 (AGND) |
If the result is not as specified, replace the power switch.
Apply battery voltage between the terminals of the switch, and check the illumination condition of the power switch.
| *a | Indicator Light | - | - |
If a positive (+) auxiliary battery lead and a negative (-) auxiliary battery lead are incorrectly connected, the power switch indicator light will not illuminate.
If the voltage is too low, the indicator light will not illuminate.
| Measurement Condition | Specified Condition |
|---|---|
| Auxiliary battery positive (+) → Terminal I58-9 (SWIL)
Auxiliary battery negative (-) → Terminal I58-6 (AGND) |
Illuminates |
If the result is not as specified, replace the power switch.