Home › Power Source / Network › 2AR-FXE BATTERY / CHARGING › BATTERY THERMOMETER SENSOR
RM2040EQ _57 Power Source / Network _014719 2AR-FXE BATTERY / CHARGING _0075037 BATTERY THERMOMETER SENSOR G

2AR-FXE BATTERY / CHARGING  BATTERY THERMOMETER SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 88790F 1.INSPECT AUXILIARY BATTERY THERMOMETER SENSOR

a.
A294423
3.063,0.51 2.823,0.156 2.823,0.156 2.656,0.156 false 1.26,2.917 1.646,2.333 1.646,2.333 1.875,2.333 false 0.052,0.042 0.365,0.198 0.313,0.156 10 *a 2.479,0.083 2.792,0.24 0.313,0.156 10 *b 0.177,1.427 0.49,1.583 0.313,0.156 10 *c 1.688,4.427 2,4.583 0.313,0.156 10 *d 1.927,2.24 2.24,2.396 0.313,0.156 10 *e
*a Component without harness connected
(Auxiliary Battery Thermistor Assembly)
*b Sensing Portion
*c Resistance (kΩ)
*d Temperature °C (°F)
*e Allowable Range


Disconnect the connector from the auxiliary battery thermometer sensor.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
1 - 2 60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Hold the sensor only by its connector. Touching the sensor may change the resistance value.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).


If the resistance is not as specified, replace the auxiliary battery thermometer sensor.