Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2012.02–2016.05
RM2040EQ _58 Vehicle Interior _014730 HEATING / AIR CONDITIONING _0075108 AIR CONDITIONING SYSTEM D

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  SYSTEM DESCRIPTION  


GENERAL


a.

The air conditioning system has the following controls.

Control Outline
Neural Network Control This control is capable of performing complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship similar to that of a human brain.
Outlet Air Temperature Control Based on the temperature set by the temperature control dial, neural network control calculates outlet air temperature based on input signals from various sensors.
Dual Control The temperature settings for the driver and front passenger are controlled independently in order to provide separate vehicle interior temperatures for the right and left sides of the vehicle. Thus, air conditioning that accommodates the occupants' preferences has been realized.
Blower Control Controls the blower motor with fan sub-assembly in accordance with the airflow volume that has been calculated by neural network control based on the input signals from various sensors.
Air Outlet Control Automatically switches the air outlets in accordance with the outlet mode that has been calculated by neural network control.
In accordance with the engine coolant temperature, ambient air temperature, amount of sunlight, required blower, outlet temperature and vehicle speed conditions, this control automatically switches the blower outlet to foot and defroster mode to prevent the windows from becoming fogged up when the ambient air temperature is low.
Air Inlet Control Automatically controls the air inlet control damper to help achieve the calculated outlet air temperature that is required.
Drives the air inlet control servo motor according to the operation of the air inlet control switch and moves the dampers to the fresh or recirculation position.
Electric Inverter Compressor Control The air conditioning amplifier assembly calculates the target speed of the compressor based on the target evaporator temperature (which is calculated by the room temperature sensor, outside temperature sensor, and the automatic light control sensor (solar sensor)) and the actual evaporator temperature that is detected by the evaporator temperature sensor in order to control the compressor speed.
The air conditioning amplifier assembly calculates the target evaporator temperature, which includes corrections based on the room temperature sensor, outside temperature sensor, the automatic light control sensor (solar sensor), and evaporator temperature sensor. Accordingly, the air conditioning amplifier assembly controls the compressor speed to an extent that would not inhibit the proper cooling performance or defogging performance.
Turns the air conditioning on automatically when the AUTO button is pressed when the blower is ON and the air conditioning is off.
Decreases the compressor speed in order to ensure quietness when the vehicle is stopped or the engine is off.
Defroster Control Defroster control logic is used to improve defroster performance.
PTC Heater Control When the hybrid system is operating (READY), and the blower with fan motor sub-assembly is turned on, the air conditioning amplifier assembly turns on the quick heater assembly if the conditions listed below are met.
- Engine coolant temperature is below specified temperature.
- Outside temperature is below specified temperature.
- Tentative air mix damper opening angle is above the specified value (MAX HOT).
Rear Defogger Control When the power switch is on (IG) and the rear defogger switch is pushed, the system is activated to keep the defogger heater on for approx. 15 minutes.
ECO Mode Control When the ECO mode switch (eco switch assembly) is turned on, the air conditioning amplifier assembly limits the air conditioning system performance.
Diagnosis A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier detects a problem with the air conditioning system.



NEURAL NETWORK CONTROL


·

In the previous automatic air conditioning systems, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors.

However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for effecting a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly. The air conditioning amplifier assembly can then effect control to provide enhanced air conditioning comfort.

·

The neural network control consists of neurons in the input layer, intermediate layer and output layer. The input layer neurons process the input data of the outside temperature, the amount of sunlight and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor in accordance with the control volumes that have been calculated by the neural network control.


E211120E01
3.031,0.094 4.208,0.271 1.177,0.177 10 Intermediate Layer 4.406,0.458 5.229,0.635 0.823,0.177 10 Output Layer 2.135,0.458 2.844,0.635 0.708,0.177 10 Input Layer 1.667,0.833 2.625,1.01 0.958,0.177 10 Ambient Temp. 1.438,1.417 2.625,1.594 1.188,0.177 10 Amount of Sunlight 1.813,2 2.625,2.177 0.813,0.177 10 Cabin Temp. 0.333,4.771 1.385,4.948 1.052,0.177 10 Input Processing 5.719,3.219 6.875,3.396 1.156,0.177 10 Output Processing 5.948,5.531 6.792,5.708 0.844,0.177 10 Blower Motor 2.573,3.75 3.552,3.927 0.979,0.177 10 Neural Network 2.677,6.615 3.458,6.792 0.781,0.177 10 Outlet Mode 2.729,7.25 3.396,7.427 0.667,0.177 10 Inlet Mode 2.677,7.75 3.458,7.927 0.781,0.177 10 Compressor 5.979,7.75 6.75,7.927 0.771,0.177 10 Compressor 2.438,4.26 3.698,4.438 1.26,0.177 10 Target Outlet Temp. 3.396,3.24 3.865,3.417 0.469,0.177 10 Control 0.323,5.49 1.208,5.667 0.885,0.177 10 Temp. Setting 0.365,6.594 1.167,6.771 0.802,0.177 10 Sensor Input 0.375,7.76 1.156,7.938 0.781,0.177 10 Switch Input 0.625,8.385 2.771,8.563 2.146,0.177 10 : Neural Network Operation Range 4.604,0.833 5.865,1.01 1.26,0.177 10 Target Outlet Temp. 2.458,4.792 3.656,5.125 1.198,0.333 10 Amount of Sunlight Correction 4.292,4.115 5.188,4.448 0.896,0.333 10 Temp. Control Correction 5.854,4.125 6.833,4.458 0.979,0.333 10 Air Mix Damper Servo 5.896,6.021 6.792,6.354 0.896,0.333 10 Mode Damper Servo 5.938,6.896 6.854,7.229 0.917,0.333 10 Recirculation Damper Servo 4.198,6.344 5.281,6.75 1.083,0.406 10 Various Types of Mode Correction 4.198,7.135 5.26,7.469 1.063,0.333 10 Various Types of Correction 2.583,5.708 3.5,6.042 0.917,0.333 10 Target Airflow Volume 4.198,5.135 5.26,5.656 1.063,0.521 10 Various Types of Airflow Volume Correction


MODE POSITION AND DAMPER OPERATION


a.

Mode Position and Damper Operation

E237415
2.115,2.375 1.854,2.594 false 2.604,2.417 2.302,2.844 false 0.635,2.552 0.969,2.094 false 1.729,0.073 2.792,0.219 1.063,0.146 10 false Center Defroster 0.313,0.375 1.229,0.656 0.917,0.281 10 false Side Defroster 0.073,1.073 0.698,1.24 0.625,0.167 10 false Fresh Air 1.188,0.99 2.052,1.302 0.865,0.313 10 false Recirculation Air 0.604,4.365 1.5,4.51 0.896,0.146 10 false Side Register 6.26,4.365 7.125,4.51 0.865,0.146 10 false Side Register 0.063,2.552 1.26,2.865 1.198,0.313 10 false Blower Motor with Fan Sub-assembly 1.5,2.604 2.198,2.74 0.698,0.135 10 false Evaporator 1.26,2.875 2.573,3.198 1.313,0.323 10 false Heater Radiator Unit Sub-assembly 1.104,1.677 1.24,1.906 0.135,0.229 10 false A 0.802,1.677 0.938,1.906 0.135,0.229 10 false B 5.219,2.25 5.354,2.479 0.135,0.229 10 false C 2.354,2.104 2.49,2.333 0.135,0.229 10 false C 2.281,1.906 2.417,2.135 0.135,0.229 10 false D 5,2.271 5.135,2.5 0.135,0.229 10 false D 4.917,2.083 5.052,2.313 0.135,0.229 10 false E 2.323,1.75 2.458,1.979 0.135,0.229 10 false E 5.615,2.271 5.802,2.5 0.188,0.229 10 false C' 5.865,2.271 6.063,2.5 0.198,0.229 10 false D' 5.938,2.052 6.125,2.281 0.188,0.229 10 false E' 1.854,5.51 3.708,5.656 1.854,0.146 10 false Rear Footwell Register Duct 4.979,4.729 6.906,4.865 1.927,0.135 10 false Front Footwell Register Duct 3.281,4.531 4.667,4.688 1.385,0.156 10 false Front Center Register 3.396,5.094 4.802,5.26 1.406,0.167 10 false Rear Center Register 0.51,4.729 2.365,4.875 1.854,0.146 10 false Front Footwell Register Duct 3.26,0.365 4.188,0.646 0.927,0.281 10 false Side Defroster 4.479,0.813 5.406,0.958 0.927,0.146 10 false To Driver Side 5.531,0.823 7.104,1.094 1.573,0.271 10 false To Front Passenger Side 2.167,1.01 2.302,1.24 0.135,0.229 10 false F 2.271,1.042 2.406,1.271 0.135,0.229 10 false G 2.406,1.156 2.542,1.385 0.135,0.229 10 false H 3.375,3.792 3.51,4.021 0.135,0.229 10 false J 3.729,3.583 3.865,3.813 0.135,0.229 10 false K 3.729,3.958 3.865,4.188 0.135,0.229 10 false L 3.781,3.813 3.917,4.042 0.135,0.229 10 false M 3.906,3.885 4.042,4.115 0.135,0.229 10 false N 4.313,3.583 4.448,3.813 0.135,0.229 10 false O 4.208,3.771 4.344,4 0.135,0.229 10 false P 2.792,1.646 2.927,1.875 0.135,0.229 10 false Q 2.865,1.792 3,2.021 0.135,0.229 10 false R 2.885,1.51 3.021,1.74 0.135,0.229 10 false S 2.823,2.49 2.958,2.719 0.135,0.229 10 false T 2.792,2.667 2.927,2.896 0.135,0.229 10 false U 2.563,2.604 2.698,2.833 0.135,0.229 10 false V 2.469,4.802 2.635,5.031 0.167,0.229 10 false W 2.958,4.708 3.094,4.938 0.135,0.229 10 false Y 2.729,4.708 2.865,4.938 0.135,0.229 10 false X 2.323,1.302 2.458,1.531 0.135,0.229 10 false I

Functions of Main Dampers
Control Damper Operation Position Damper Position Operation
Air Inlet Control Damper FRESH A Allows fresh air to enter.
RECIRCULATION B Causes internal air to recirculate.
Air Mix Control Damper MAX COLD to MAX HOT Temperature Setting C - D - E
(C' - D' - E')
T - U - V
Varies the mixture ratio of warm air and cool air in order to regulate the temperature continuously between hot and cold.
Air Outlet Control Damper DEF
E264847

F, J, L, P, S, Y Defrosts the windshield through the center defroster, side defroster, and side registers.
FOOT / DEF
E264851

G, J, L, P, Q, X Defrosts the windshield through the center defroster, side defrosters, side registers, and rear center register, while air is also blown out from the front and rear footwell register ducts.
FOOT
E264850

H, J, L, P, Q, X Air blows out of the front and rear footwell register duct, and side registers. In addition, air blows out slightly from the center defroster and side defrosters.
BI-LEVEL
E264849

I, K, N, O, R, X Air blows out of the front and rear center registers, side registers and front and rear footwell registers ducts.
FACE
E264852

I, K, M, O, S, W Air blows out of the front and rear center registers, and side registers.



AIR OUTLETS AND AIRFLOW VOLUME


a.

Air Outlets and Airflow Volume

E230464E01
2.735,0.711 2.858,0.863 0.123,0.152 10 F 5.157,0.905 5.308,1.057 0.151,0.152 10 G 1.884,1.791 2.034,1.943 0.151,0.152 10 G 2.191,2.745 2.342,2.897 0.151,0.152 10 B 5.54,1.785 5.691,1.937 0.151,0.152 10 B 3.707,2.215 3.857,2.366 0.151,0.152 10 A 2.493,3.473 2.643,3.625 0.151,0.152 10 D 4.481,2.981 4.632,3.133 0.151,0.152 10 D 3.647,4.648 3.798,4.8 0.151,0.152 10 E 5.066,4.249 5.217,4.4 0.151,0.152 10 E 5.399,4.158 5.55,4.31 0.151,0.152 10 C 5.718,4.039 5.869,4.19 0.151,0.152 10 C 4.126,2.066 4.277,2.217 0.151,0.152 10 A

MODE Selection Register Footwell Defroster
Automatic Manual CTR SIDE RR FR RR CTR SIDE
A B C D E F G
FACE-U*1
E264852

E263105

E263105

E264853

E264853

E264853

E264858

E264858

E264858

E264858

B/L-U*2
E264849

E263105

E263105

E264854

E264854

E264854

E264855

E264855

E264858

E264858

FOOT-F*3
E264850

E263105

E264858

E264858

E264855

E264855

E264854

E264855

E264856

E264856

FOOT-R*4
E263105

E263105

E264858

E264855

E264855

E264854

E264854

E264856

E264856

FOOT-D*5
E263105

E264858

E264858

E264855

E264855

E264855

E264855

E264855

E264855

F/D
E264851

E263105

E263105

E264858

E264855

E264855

E264854

E264854

E264854

E264854

DEF
E264847

E263105

E263105

E264858

E264855

E264858

E264858

E264858

E264857

E264857


·

*1: Air blows out of registers only

·

*2: Regular bi-level mode

·

*3: Regular foot mode

·

*4: Foot mode with large airflow volume from the rear footwell register ducts.

·

*5: Foot mode with large airflow volume from defrosters

·

The size of each circle ○ indicates the ratio of airflow volume.




COMPRESSOR WITH MOTOR ASSEMBLY


a.

General

HINT:

In order to ensure the proper insulation of the internal high-voltage portion of the compressor and the compressor housing, this vehicle has adopted a compressor oil (ND-OIL 11) with a high level of insulation performance. Therefore, never use a compressor oil other than the ND-OIL 11 type compressor oil or its equivalent.


i.

Along with the use of the hybrid system on this vehicle, an electric inverter compressor that is driven by a motor is used. The basic construction and operation of this compressor are the same as an ordinary scroll compressor, except that it is driven by an electric motor.


ii.

The Air Conditioning (A/C) inverter is integrated with the compressor.


iii.

The electric motor is actuated by 3-phase alternating current (244.8 V) supplied by the A/C inverter. As a result, the air conditioning control system on this vehicle is actuated without depending on the operation of the engine, thus realizing a comfortable air conditioning system and low fuel consumption.


iv.

Due to the use of an electric inverter compressor, the compressor speed can be controlled at the required speed calculated by the air conditioning amplifier assembly. Thus, the cooling and dehumidification performance and power consumption have been optimized.


v.

Low-moisture permeation hoses are used for the suction and discharge hoses at the compressor in order to minimize the entry of moisture into the refrigeration cycle.


vi.

The compressor uses high-voltage alternating current. If a short or open circuit occurs in the compressor, the power management control ECU will cut off the A/C inverter circuit in order to stop the power supply to the compressor motor.



b.

Compressor Speed Control

i.

The air conditioning amplifier assembly calculates the target compressor speed based on the target evaporator temperature (calculated from the temperature control switch, room temperature sensor, ambient temperature sensor, and automatic light control sensor (solar sensor)) and the actual evaporator temperature detected by the evaporator temperature sensor. Then, the air conditioning amplifier assembly transmits the target speed to the power management control ECU. The power management control ECU controls the A/C inverter based on the target speed data in order to control the compressor to a speed that suits the operating condition of the air conditioning system.


ii.

The air conditioning amplifier assembly calculates the target evaporator temperature, which includes corrections based on the room temperature sensor, outside temperature sensor, automatic light control sensor (solar sensor), and evaporator temperature sensor. Accordingly, the air conditioning amplifier assembly controls the compressor speed to an extent that does not inhibit the proper cooling performance or defogging performance. As a result, comfort and low fuel consumption can be realized.




EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR)


The evaporator temperature sensor (No. 1 cooler thermistor) detects the temperature of the cool air immediately through the evaporator in the form of resistance changes, and outputs it to the air conditioning amplifier assembly.


BLOWER MOTOR WITH FAN SUB-ASSEMBLY


The blower motor with fan sub-assembly has a built-in blower controller, and is controlled using duty control performed by the air conditioning amplifier assembly.


BUS CONNECTOR (AIR CONDITIONING HARNESS ASSEMBLY)


a.

BUS connectors are used in the wire harness that connects the servo motors to the air conditioning amplifier assembly.

E116948
0.171,1.929 1.14,2.094 0.969,0.165 10 Bus Connector 2.554,1.938 3.523,2.103 0.969,0.165 10 Bus Connector 3.006,3.598 3.975,3.763 0.969,0.165 10 Bus Connector 5.339,4.513 6.308,4.678 0.969,0.165 10 Bus Connector 0.187,2.09 2.437,2.278 2.25,0.188 10 (to Air Mix Servo Motor (for Driver)) 2.569,2.09 4.24,2.273 1.671,0.183 10 (to Air Inlet Servo Motor) 0.226,4.17 2.303,4.408 2.076,0.237 10 Evaporator Temperature Sensor 3.011,3.785 3.91,4.11 0.899,0.325 10 (to Air Outlet Servo Motor) 5.353,4.679 6.824,5.027 1.472,0.348 10 (to Air Mix Servo Motor (for Front Passenger)) 4.919,4.588 5.302,4.588 false 4.447,3.676 4.003,3.676 false 1.135,3.752 1.135,4.121 false 6.041,1.696 7.091,1.883 1.05,0.186 10 to A/C Amplifier 0.151,0.091 0.862,0.351 0.712,0.26 10 Example:


b.

Each BUS connector has a built-in communication/driver IC which communicates with the air conditioning amplifier assembly, actuates the servo motor, and has a position detection function. This enables bus communication for the servo motor wire harness, for a more lightweight construction and a reduced number of wires.

E224000E06
0.106,0.249 1.595,0.426 1.489,0.177 12 w/ BUS Connector: 0.106,3.207 1.751,3.384 1.645,0.177 12 w/o BUS Connector: 0.281,0.764 2.516,0.928 2.235,0.164 10 Air Conditioning Amplifier Assembly 0.281,3.72 2.516,3.884 2.235,0.164 10 Air Conditioning Amplifier Assembly 0.654,1.214 2.13,1.374 1.476,0.16 10 Communication Circuit 1.267,1.829 1.594,1.982 0.326,0.153 10 CPU 1.561,4.519 2.09,4.678 0.529,0.159 10 Drive IC 1.561,5.782 2.09,5.941 0.529,0.159 10 Drive IC 0.462,5.083 0.786,5.229 0.325,0.145 10 CPU 3.75,0.572 4.737,0.742 0.987,0.17 10 BUS Connector 5.293,0.454 6.904,0.624 1.611,0.17 10 Communication/Driver IC 6.214,1.916 7.0,2.09 0.786,0.175 10 Servo Motor 6.214,5.139 7.0,5.314 0.786,0.175 10 Servo Motor 5.035,1.067 5.198,0.514 5.198,0.514 5.266,0.514 false 4.881,0.997 4.813,0.656 4.813,0.656 4.766,0.656 false



SERVO MOTOR


The pulse pattern type servo motor consists of a printed circuit board and a servo motor. The printed circuit board has three contact points, and can transmit two ON-OFF signals to the air conditioning amplifier assembly based on the difference of the pulse phases. The BUS connector can detect the damper position and movement direction with these signals.

E116950E04
0.476,0.516 1.410,0.686 0.934,0.170 10 Contact Points 1.415,4.019 2.816,4.188 1.401,0.170 10 Printed Circuit Board 0.088,3.949 0.868,4.285 0.781,0.336 10 Conductive Portion 2.627,1.56 2.751,1.737 0.124,0.178 10 A 3.046,2.516 3.170,2.694 0.124,0.178 10 A 3.229,1.101 3.354,1.279 0.124,0.178 10 A 2.627,1.766 2.751,1.944 0.124,0.178 10 B 3.046,3.181 3.170,3.359 0.124,0.178 10 B 3.229,1.668 3.354,1.846 0.124,0.178 10 B 2.627,1.966 2.958,2.132 0.331,0.166 10 GND 3.021,1.385 3.352,1.551 0.331,0.166 10 GND 3.341,2.379 3.501,2.556 0.159,0.177 10 Hi 3.324,2.684 3.501,2.861 0.177,0.177 10 Lo 3.341,3.048 3.501,3.225 0.159,0.177 10 Hi 3.324,3.353 3.501,3.530 0.177,0.177 10 Lo 4.757,3.917 5.419,4.087 0.663,0.170 10 1 Rotation 2.676,0.705 3.658,0.889 0.982,0.184 10 Contact Points: 4.682,0.099 5.889,0.283 1.207,0.184 10 Conductive Portion 6.221,0.092 7.147,0.430 0.926,0.338 10 Printed Circuit Board 6.261,1.147 6.135,0.154 false 4.474,1.158 4.544,0.173 false 1.517,1.525 1.517,0.586 1.517,0.586 1.436,0.586 false 1.281,3.247 1.281,4.096 1.281,4.096 1.373,4.096 false 1.156,2.898 0.322,3.78 0.322,3.78 0.322,3.949 false 4.544,0.173 4.656,0.173 false 6.135,0.154 6.225,0.154 false


PTC HEATER


a.

General

i.

The quick heater assembly is located above the heater core in the air conditioning unit.


ii.

The quick heater assembly consists of a PTC element, aluminum fins, and brass plates. When current is applied to the PTC element, it generates heat to warm the air that passes through the unit.

E235664C03
1.552,1.427 1.552,0.552 1.552,0.552 1.677,0.552 false 5.521,1.406 4.958,0.833 4.958,0.833 4.792,0.833 false 5.521,1.979 5.104,1.979 false 5.677,2.156 5.677,2.844 5.677,2.844 5.885,2.844 false 1.708,0.458 1.979,0.667 0.271,0.208 10 false *1 4.635,0.76 4.813,0.917 0.177,0.156 10 false *3 4.958,1.906 5.125,2.063 0.167,0.156 10 false *4 5.896,2.781 6.104,2.938 0.208,0.156 10 false *2
*1 Quick Heater Assembly *2 Brass Plate
*3 PTC Element *4 Aluminum Fin




b.

Quick Heater Assembly Operating Conditions

i.

The quick heater assembly is turned on and off by the air conditioning amplifier assembly in accordance with the engine coolant temperature, ambient temperature, temperature setting, and electrical load (generator power ratio).




ECO MODE CONTROL


Under the control of eco mode, the air conditioning amplifier assembly restricts the air conditioning system performance under specified conditions, thus improving fuel economy.


ROOM TEMPERATURE SENSOR (COOLER THERMISTOR)


The room temperature sensor (cooler thermistor) detects the cabin temperature based on changes in the resistance of its built-in thermistor and sends a signal to the air conditioning amplifier assembly.


AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY)


The ambient temperature sensor (thermistor assembly) detects the outside temperature based on changes in the resistance of its built-in thermistor and sends a signal to the air conditioning amplifier assembly.


SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR)


a.

The solar sensor (automatic light control sensor) consists of a photo diode, two amplifier circuits for the solar sensor (automatic light control sensor), and frequency converter circuit for the light control sensor.


b.

The solar sensor (automatic light control sensor) detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight from the LH and RH sides (2 directions) and outputs these sunlight strength signals to the air conditioning amplifier assembly.

E222715E06
0.193,1.092 0.717,1.255 0.524,0.163 10 LH Side 2.336,1.099 2.878,1.262 0.542,0.163 10 RH Side 0.247,2.448 0.719,2.788 0.472,0.34 10 Sensor Portion 3.373,3.946 5.19,4.275 1.817,0.329 10 to Main Body ECU (Multiplex Network Body ECU) 5.647,3.946 6.856,4.306 1.208,0.36 10 to Air Conditioning Amplifier Assembly 3.012,0.408 7.067,0.588 4.054,0.179 10 Internal circuit of the solar sensor (automatic light control sensor) 4.255,0.81 5.054,0.976 0.8,0.166 10 Photo Diode 3.531,1.598 4.599,1.905 1.068,0.306 10 Frequency Converter Circuit 5.312,1.598 6.316,1.923 1.003,0.325 10 Amplifier Circuit (LH) 5.312,2.598 6.316,2.953 1.003,0.355 10 Amplifier Circuit (RH) 1.524,1.988 0.828,2.522 0.828,2.522 0.733,2.522 false



AIR CONDITIONING PRESSURE SENSOR


The air conditioning pressure sensor detects the refrigerant pressure and outputs it to the air conditioning amplifier assembly in the form of voltage changes.