Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2012.02–2016.05
RM2040EQ _58 Vehicle Interior _014730 HEATING / AIR CONDITIONING _0075108 AIR CONDITIONING SYSTEM U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the intelligent tester on.


d.

Enter the following menus: Body / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Room temperature sensor (cooler thermistor) Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed -
Ambient Temp Sensor Ambient temperature sensor (thermistor assembly) Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed -
Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
- -
Evaporator Fin Thermistor Evaporator temperature sensor (No. 1 cooler thermistor) Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed -
Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed -
Solar Sensor (D Side) Driver side automatic light control sensor (solar sensor) Min.: 0
Max.: 255
Driver side automatic light control sensor (solar sensor) value increases as brightness increases -
Solar Sensor (P Side) Front passenger side automatic light control sensor (solar sensor) Min.: 0
Max.: 255
Front passenger side automatic light control sensor (solar sensor) value increases as brightness increases -
Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed -
Set Temperature (D Side) Driver side set temperature Min.: MAX COLD
Max.: MAX HOT
Driver side set temperature displayed -
Set Temperature (P Side) Front passenger side set temperature Min.: MAX COLD
Max.: MAX HOT
Front passenger side set temperature displayed -
Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases -
Regulator Pressure Sensor Air conditioning pressure sensor Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual pressure displayed -
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix*1) target pulse Min.: 0
Max.: 255
MAX. COLD: 105 (pulse)
MAX. HOT: 7 (pulse)
-
Air Mix Servo Actual Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix*1) actual pulse Min.: 0
Max.: 255
MAX. COLD: 105 (pulse)
MAX. HOT: 7 (pulse)
-
Air Mix Servo Targ Pulse(P) No. 2 air conditioning radiator damper servo sub-assembly (air mix*2) target pulse Min.: 0
Max.: 255
MAX. COLD: 5 (pulse)
MAX. HOT: 103 (pulse)
-
Air Mix Servo Actual Pulse(P) No. 2 air conditioning radiator damper servo sub-assembly (air mix*2) actual pulse Min.: 0
Max.: 255
MAX. COLD: 5 (pulse)
MAX. HOT: 103 (pulse)
-
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) target pulse Min.: 0
Max.: 255
FACE: 8 (pulse)
B/L: 30 (pulse)
FOOT (Manual mode) : 67 (pulse)
FOOT (Automatic mode) : 60, 67 or 74 (pulse)
FOOT/DEF: 80 (pulse)
DEF: 97 (pulse)
-
Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse Min.: 0
Max.: 255
FACE: 8 (pulse)
B/L: 30 (pulse)
FOOT (Manual mode) : 67 (pulse)
FOOT (Automatic mode) : 60, 67 or 74 (pulse)
FOOT/DEF: 80 (pulse)
DEF: 97 (pulse)
-
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (air inlet) target pulse Min.: 0
Max.: 255
RECIRCULATION: 7 (pulse)
FRESH: 28 (pulse)
-
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly (air inlet) actual pulse Min.: 0
Max.: 255
RECIRCULATION: 7 (pulse)
FRESH: 28 (pulse)
-
Electric Heater Count Maximum heater operation level Min.: 0
Max.: 2
Maximum possible operation level of quick heater assembly displayed -
Electric Heater Active Level Actual heater operation level Min.: 0
Max.: 2
Actual operation level of quick heater assembly displayed -
Compressor Speed Compressor speed Min.: 0 rpm
Max.: 65535 rpm
Actual compressor rotation speed displayed -
Compressor Target Speed Compressor target speed Min.: 0 rpm
Max.: 65535 rpm
Compressor target rotation speed displayed -
Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr, 2C incr Customized value displayed -
Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
Compressor Mode Compressor mode Auto or Manual Customized value displayed -
Noise and Vibration Reduction Noise and vibration reduction OFF or ON Customized value displayed -
ECO MODE Cancel ECO MODE Cancel OFF or ON Customized value displayed -
ECO Switch ECO mode switch (eco switch assembly) OFF or ON ECO mode switch (eco switch assembly) not operated: OFF
(when switch is not pressed)
ECO mode switch (eco switch assembly) operated: ON
(when switch is pressed)
-
Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
Fan speed increment control Fan speed increment control Slow, Normal, Fast Customized value displayed -
Foot/DEF Auto Mode Foot/DEF Auto Mode ON or OFF Customized value displayed -
Foot/DEF Auto Blow Up Foot/DEF Auto blower speed increase ON or OFF Customized value displayed -
Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr Customized value displayed -
Compressor Drive Check Compressor drive check OK or NG NG: Compressor does not drive
OK: Compressor drives
-
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -

*1: for Driver Side

*2: for Front Passenger Side




ACTIVE TEST


Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the intelligent tester on.


d.

Enter the following menus: Body / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0, Max.: 31 -
Compressor Target Speed Compressor with motor assembly Min.: 0, Max.: 7500 -
Defogger Relay (Rear) Defogger relay (engine room junction block assembly) OFF, ON -
Water Pump Engine water pump assembly OFF, ON -
Heater Active Level Quick heater assembly Min.: 0, Max.: 2 -
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix*1) pulse Min.: 0, Max.: 255 Operates between 7 and 105 pulses
Air Mix Servo Targ Pulse(P) No. 2 air conditioning radiator damper servo sub-assembly (air mix*2) pulse Min.: 0, Max.: 255 Operates between 5 and 103 pulses
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) pulse Min.: 0, Max.: 255 Operates between 8 and 97 pulses
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (air inlet) target pulse Min.: 0, Max.: 255 Operates between 7 and 28 pulses

*1: for Driver Side

*2: for Front Passenger Side