When the ECO mode switch (eco switch assembly) is turned on, the air conditioning amplifier assembly receives an ECO mode switch (eco switch assembly) ON signal and controls the air conditioning to enhance fuel efficiency.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data Test.
Check the values by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| ECO Switch | ECO mode switch (eco switchassembly) | OFF or ON | ECO mode switch (eco switch assembly) not operated: OFF (when switch is not pressed)
ECO mode switch (eco switch assembly) operated: ON (when switch is pressed) |
- |
| Tester Display |
|---|
| ECO Switch |
ECO mode switch (eco switch assembly) condition displayed on the intelligent tester changes with the actual switch operation.
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>PROBLEM SYMPTOMS TABLE
NG
Remove the ECO mode switch (eco switch assembly).
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>COMBINATION SWITCH>REMOVAL
| *a | Component without harness connected
(ECO Mode Switch (Eco Switch Assembly)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I49-9 (ECU) - I49-6 (E) | ECO mode switch (eco switch assembly) off (when switch is not pressed) | 10 kΩ or higher |
| I49-9 (ECU) - I49-6 (E) | ECO mode switch (eco switch assembly) on (when switch is pressed) | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I77 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I77-4 (ECOS) - I49-9 (ECU) | Always | Below 1 Ω |
| I77-4 (ECOS) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I49-6 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG