Home › Vehicle Interior › HEATING / AIR CONDITIONING › ROOM TEMPERATURE SENSOR
RM2040EQ _58 Vehicle Interior _014730 HEATING / AIR CONDITIONING _0075114 ROOM TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  ROOM TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88625Q 1.INSPECT ROOM TEMPERATURE SENSOR (COOLER THERMISTOR)

a.

Measure the resistance according to the value(s) in the table below.

E265299
1.76,0.26 2.229,0.5 0.469,0.24 2.073,0.99 2.563,0.781 false 1.469,0.813 1.875,0.99 false 1.99,1.604 2.583,1.333 2.583,1.333 2.823,1.333 false 4.656,1.292 5.01,0.833 5.01,0.833 5.25,0.833 false 0.125,0.115 0.677,0.51 0.552,0.396 10 *a 3.99,0.115 4.427,0.417 0.438,0.302 10 *c 2.635,0.677 2.906,0.896 0.271,0.219 10 + 2.885,1.24 3.323,1.542 0.438,0.302 10 *b 1.365,0.677 1.635,0.896 0.271,0.219 10 - 5.271,0.719 5.708,1.021 0.438,0.302 10 *d 1.906,0.281 2.344,0.583 0.438,0.302 10 I57 3.813,0.333 4.177,0.542 0.365,0.208 10 4.0 3.813,0.552 4.177,0.76 0.365,0.208 10 3.5 3.813,0.781 4.177,0.99 0.365,0.208 10 3.0 3.813,1.01 4.177,1.219 0.365,0.208 10 2.5 3.813,1.24 4.177,1.448 0.365,0.208 10 2.0 3.802,1.479 4.167,1.688 0.365,0.208 10 1.5 3.802,1.698 4.167,1.906 0.365,0.208 10 1.0 3.802,1.917 4.167,2.125 0.365,0.208 10 0.5 3.802,2.156 4.167,2.365 0.365,0.208 10 0.0 3.969,2.438 4.333,2.667 0.365,0.229 10 (50) 4,2.271 4.333,2.5 0.333,0.229 10 10 4.458,2.271 4.792,2.5 0.333,0.229 10 20 4.906,2.271 5.24,2.5 0.333,0.229 10 30 5.375,2.271 5.708,2.5 0.333,0.229 10 40 5.833,2.271 6.167,2.5 0.333,0.229 10 50 6.26,2.271 6.594,2.5 0.333,0.229 10 60 4.427,2.438 4.792,2.667 0.365,0.229 10 (68) 4.875,2.438 5.24,2.667 0.365,0.229 10 (86) 5.313,2.448 5.677,2.677 0.365,0.229 10 (104) 5.771,2.448 6.135,2.677 0.365,0.229 10 (122) 6.198,2.448 6.563,2.677 0.365,0.229 10 (140) 5.156,2.594 5.573,2.792 0.417,0.198 10 *e
*a Component without harness connected
(Room Temperature Sensor (Cooler Thermistor))
*b Sensing Portion
*c Resistance (kΩ) *d Allowable Range
*e Temperature (°C (°F)) - -


Standard Resistance:
Tester Connection Condition Specified Condition
I57-1 (+) - I57-2 (-) 10°C (50°F) 3.00 to 3.73 kΩ
I57-1 (+) - I57-2 (-) 15°C (59°F) 2.45 to 2.88 kΩ
I57-1 (+) - I57-2 (-) 20°C (68°F) 1.95 to 2.30 kΩ
I57-1 (+) - I57-2 (-) 25°C (77°F) 1.60 to 1.80 kΩ
I57-1 (+) - I57-2 (-) 30°C (86°F) 1.28 to 1.47 kΩ
I57-1 (+) - I57-2 (-) 35°C (95°F) 1.00 to 1.22 kΩ
I57-1 (+) - I57-2 (-) 40°C (104°F) 0.80 to 1.00 kΩ
I57-1 (+) - I57-2 (-) 45°C (113°F) 0.65 to 0.85 kΩ
I57-1 (+) - I57-2 (-) 50°C (122°F) 0.50 to 0.70 kΩ
I57-1 (+) - I57-2 (-) 55°C (131°F) 0.44 to 0.60 kΩ
I57-1 (+) - I57-2 (-) 60°C (140°F) 0.36 to 0.50 kΩ


If the resistance is not as specified, replace the room temperature sensor (cooler thermistor).

NOTICE:
·

Hold the sensor only by its connector. Touching the sensor may change the resistance value.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).