Home › Vehicle Interior › HEATING / AIR CONDITIONING › AMBIENT TEMPERATURE SENSOR
RM2040EQ _58 Vehicle Interior _014730 HEATING / AIR CONDITIONING _0075115 AMBIENT TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  AMBIENT TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88790B 1.INSPECT AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY)

a.

Measure the resistance according to the value(s) in the table below.

E265303
0.917,0.563 1.333,0.771 0.417,0.208 4.719,1.354 5.115,1.104 false 2.823,1.344 2.594,0.885 2.594,0.885 2.458,0.885 false 1.208,1.49 1.375,1.75 false 1.052,1.479 0.865,1.76 false 0.229,0.094 0.646,0.354 0.417,0.26 10 *a 2.281,0.771 2.708,1.01 0.427,0.24 10 *b 4.031,0.125 4.438,0.354 0.406,0.229 10 *c 5.146,0.948 5.563,1.188 0.417,0.24 10 *d 5.25,2.604 5.646,2.792 0.396,0.188 10 *e 3.885,2.219 4.177,2.427 0.292,0.208 10 0.0 1.031,0.563 1.458,0.802 0.427,0.24 10 A3 0.781,1.729 1.052,1.927 0.271,0.198 10 + 1.427,1.708 1.698,1.906 0.271,0.198 10 - 3.885,1.99 4.177,2.198 0.292,0.208 10 0.5 3.885,1.76 4.177,1.969 0.292,0.208 10 1.0 3.885,1.542 4.177,1.75 0.292,0.208 10 1.5 3.885,1.302 4.177,1.51 0.292,0.208 10 2.0 3.885,1.063 4.177,1.271 0.292,0.208 10 2.5 3.885,0.844 4.177,1.052 0.292,0.208 10 3.0 3.885,0.615 4.177,0.823 0.292,0.208 10 3.5 3.896,0.396 4.188,0.604 0.292,0.208 10 4.0 4.042,2.344 4.333,2.552 0.292,0.208 10 10 4.51,2.354 4.802,2.563 0.292,0.208 10 20 4.979,2.344 5.271,2.552 0.292,0.208 10 30 5.448,2.344 5.74,2.552 0.292,0.208 10 40 5.906,2.344 6.198,2.552 0.292,0.208 10 50 6.365,2.333 6.656,2.542 0.292,0.208 10 60 4.01,2.5 4.365,2.771 0.354,0.271 10 (50) 4.49,2.5 4.844,2.771 0.354,0.271 10 (68) 4.958,2.5 5.313,2.771 0.354,0.271 10 (86) 5.396,2.5 5.75,2.771 0.354,0.271 10 (104) 5.844,2.5 6.198,2.771 0.354,0.271 10 (122) 6.281,2.5 6.635,2.771 0.354,0.271 10 (140)
*a Component without harness connected
(Ambient Temperature Sensor (Thermistor Assembly))
*b Sensing Portion
*c Resistance (kΩ) *d Allowable Range
*e Temperature (°C (°F)) - -


Standard Resistance:
Tester Connection Condition Specified Condition
A3-1 (-) - A3-2 (+) 10°C (50°F) 3.00 to 3.73 kΩ
A3-1 (-) - A3-2 (+) 15°C (59°F) 2.45 to 2.88 kΩ
A3-1 (-) - A3-2 (+) 20°C (68°F) 1.95 to 2.30 kΩ
A3-1 (-) - A3-2 (+) 25°C (77°F) 1.60 to 1.80 kΩ
A3-1 (-) - A3-2 (+) 30°C (86°F) 1.28 to 1.47 kΩ
A3-1 (-) - A3-2 (+) 35°C (95°F) 1.00 to 1.22 kΩ
A3-1 (-) - A3-2 (+) 40°C (104°F) 0.80 to 1.00 kΩ
A3-1 (-) - A3-2 (+) 45°C (113°F) 0.65 to 0.85 kΩ
A3-1 (-) - A3-2 (+) 50°C (122°F) 0.50 to 0.70 kΩ
A3-1 (-) - A3-2 (+) 55°C (131°F) 0.44 to 0.60 kΩ
A3-1 (-) - A3-2 (+) 60°C (140°F) 0.36 to 0.50 kΩ


If the resistance is not as specified, replace the ambient temperature sensor (thermistor assembly).

NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).