HEATING / AIR CONDITIONING  SOLAR SENSOR  INSPECTION  


PROCEDURE

Hide 89120A 1.INSPECT SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR)

a.
E221132
1.469,0.823 1.927,1.104 0.458,0.281 1.896,2.719 2.573,2.802 false 1.448,2.49 0.865,2.656 false 0.292,0.208 0.635,0.479 0.344,0.271 10 false *a 0.5,2.583 1.01,2.854 0.51,0.271 10 false CLTE 2.615,2.719 3.208,3.01 0.594,0.292 10 false CLTB 1.583,0.875 2.073,1.219 0.49,0.344 10 false I61
*a Front view of wire harness connector
(to Solar Sensor (Automatic Light Control Sensor))


Disconnect the solar sensor (automatic light control sensor) connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
I61-6 (CLTB) - I61-3 (CLTE) Power switch off Below 1 V
I61-6 (CLTB) - I61-3 (CLTE) Power switch on (IG) 11 to 14 V


If the voltage is not as specified, repair or replace the wire harness or connector.


c.
E221134
1.563,0.271 2.021,0.552 0.458,0.281 2.01,1.427 2.667,1.427 false 0.875,1.438 1.531,1.438 false 2.021,1.667 2.677,1.667 false 0.25,0.146 0.542,0.406 0.292,0.26 10 false *a 2.698,1.323 3.094,1.583 0.396,0.26 10 false TSL 0.552,1.333 1,1.594 0.448,0.26 10 false TSR 2.708,1.563 3.229,1.906 0.521,0.344 10 false CLTE 1.688,0.323 2.135,0.615 0.448,0.292 10 false I61
*a Component with harness connected
(Solar Sensor (Automatic Light Control Sensor))


Reconnect the solar sensor (automatic light control sensor) connector.


d.

Turn the power switch on (IG).


e.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
I61-1 (TSL) - I61-3 (CLTE) Sensor is exposed to electric light 0.8 to 4.3 V
I61-1 (TSL) - I61-3 (CLTE) Sensor is covered with a cloth Below 0.8 V
I61-2 (TSR) - I61-3 (CLTE) Sensor is exposed to electric light 0.8 to 4.3 V
I61-2 (TSR) - I61-3 (CLTE) Sensor is covered with a cloth Below 0.8 V


NOTICE:
·

The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 1 (2) and the negative (-) lead to terminal 6 of the solar sensor (automatic light control sensor).

·

Do not bring the positive and negative tester probes too close to each other as a short circuit may occur.



HINT:
·

Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor (automatic light control sensor).

·

As the inspection light is moved away from the sensor, the voltage decreases.



If the voltage is not as specified, replace the solar sensor (automatic light control sensor).