89120A
1.INSPECT SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR)
| *a | Front view of wire harness connector
(to Solar Sensor (Automatic Light Control Sensor)) |
Disconnect the solar sensor (automatic light control sensor) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I61-6 (CLTB) - I61-3 (CLTE) | Power switch off | Below 1 V |
| I61-6 (CLTB) - I61-3 (CLTE) | Power switch on (IG) | 11 to 14 V |
If the voltage is not as specified, repair or replace the wire harness or connector.
| *a | Component with harness connected
(Solar Sensor (Automatic Light Control Sensor)) |
Reconnect the solar sensor (automatic light control sensor) connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I61-1 (TSL) - I61-3 (CLTE) | Sensor is exposed to electric light | 0.8 to 4.3 V |
| I61-1 (TSL) - I61-3 (CLTE) | Sensor is covered with a cloth | Below 0.8 V |
| I61-2 (TSR) - I61-3 (CLTE) | Sensor is exposed to electric light | 0.8 to 4.3 V |
| I61-2 (TSR) - I61-3 (CLTE) | Sensor is covered with a cloth | Below 0.8 V |
The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 1 (2) and the negative (-) lead to terminal 6 of the solar sensor (automatic light control sensor).
Do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor (automatic light control sensor).
As the inspection light is moved away from the sensor, the voltage decreases.
If the voltage is not as specified, replace the solar sensor (automatic light control sensor).