Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING PRESSURE SENSOR
RM2040EQ _58 Vehicle Interior _014730 HEATING / AIR CONDITIONING _0075118 AIR CONDITIONING PRESSURE SENSOR G

HEATING / AIR CONDITIONING  AIR CONDITIONING PRESSURE SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 88719A 1.INSPECT AIR CONDITIONING PRESSURE SENSOR

a.

Check the wire harness.

i.

Disconnect the A55 air conditioning pressure sensor connector.


ii.

Disconnect the I77 air conditioning amplifier assembly connector.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A55-1 (-) - I77-13 (SG-2) Always Below 1 Ω
A55-2 (PR) - I77-9 (PRE) Always Below 1 Ω
A55-3 (+) - I77-10 (S5-3) Always Below 1 Ω
A55-1 (-) - Body ground Always 10 kΩ or higher
A55-2 (PR) - Body ground Always 10 kΩ or higher
A55-3 (+) - Body ground Always 10 kΩ or higher


If the resistance is not as specified, repair the wire harness.


iv.

Reconnect the I77 air conditioning amplifier assembly connector.


v.

Turn the power switch on (IG).


vi.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch condition Specified Condition
A55-3 (+) - Body ground Power switch on (IG) 4.75 to 5.25 V


If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.



b.

Check the air conditioning pressure sensor.

i.

Install a manifold gauge set.


ii.

Connect the connector to the air conditioning pressure sensor.


iii.

Turn the power switch on (READY).


iv.

Turn the A/C switch on.


v.
E227427
1.26,0.313 1.719,0.594 0.458,0.281 1.573,1.021 1.969,1.615 false 1.323,1.021 0.927,1.615 false 0.177,0.167 0.333,0.313 0.156,0.146 10 *a 1.865,1.646 2.302,1.854 0.438,0.208 10 PRE 0.729,1.615 1.25,1.823 0.521,0.208 10 SG-2 1.375,0.365 1.677,0.521 0.302,0.156 10 I77
*a Component with harness connected
(Air Conditioning Amplifier)


Measure the voltage according to the value(s) in the table below.

HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


Standard Voltage:
Tester Connection Condition Specified Condition
I77-9 (PRE) - I77-13 (SG-2) Refrigerant pressure:
(less than 3025 kPa (30.9 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 25 psi))
0.50 to 4.80 V


If the voltage is not as specified, replace the air conditioning pressure sensor.