Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM
RM2040EQ _59 Vehicle Exterior _014733 WINDOW / GLASS _0075142 POWER WINDOW CONTROL SYSTEM U

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM  FAIL-SAFE CHART  


POWER WINDOW OPERATION IN FAIL-SAFE MODE


HINT:

If the pulse sensor built into the power window regulator motor malfunctions, the power window control system enters fail-safe mode.


a.

The power window control system prohibits the following power window operations when the pulse sensor for the jam protection function has problems and the window position or the learned value is abnormal.

Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Power switch on (IG) Power switch off
(Key-off operation permitted)
Power switch off
(Key-off operation prohibited)
Manual up (Driver door window) X X -
Manual down (Driver door window) ○ X -
Auto up (Driver door window)
(hold switch at auto up position)
○* X -
Auto up (Driver door window) X X -
Auto down (Driver door window) X X -

HINT:
·

○: Operates

·

X: Operation prohibited

·

*: Operates in manual mode without jam protection



Key-linked and Wireless Transmitter-linked Operation*
Power Window Operation Condition
Power switch on (IG) Power switch off
(Key-off operation permitted)
Power switch off
(Key-off operation prohibited)
Key-linked open and close - X X
Wireless transmitter-linked open - X X

*: This function is set through the customize function, as it is off by default.


HINT:

X: Operation prohibited



i.

Power window regulator master switch LED control

HINT:

During normal operation (fail-safe is not operating), or during fail-safe mode when there is a pulse sensor malfunction or the window position or learned value is abnormal, the LED illuminates as shown in the illustration.


1.

For driver door:

B274523
4.625,0.823 5.198,0.198 5.198,0.198 5.354,0.198 false 0.719,1.667 1.448,2.104 0.729,0.438 10 false Key-off operation: 1.885,2.125 2.583,2.354 0.698,0.229 10 false Prohibited 1.906,1.667 2.583,1.865 0.677,0.198 10 false Permitted 0.719,3.563 1.583,4.042 0.865,0.479 10 false Window lock switch signal: 2.302,3.938 2.563,4.156 0.26,0.219 10 false Off 2.313,3.563 2.563,3.76 0.25,0.198 10 false On 0.719,2.688 1.135,2.896 0.417,0.208 10 false LED: 1.958,3.146 2.594,3.385 0.635,0.24 10 false Turns off 1.969,2.688 2.615,2.896 0.646,0.208 10 false Turns on 0.719,0.688 1.708,0.906 0.99,0.219 10 false Power switch: 2.302,1.177 2.552,1.417 0.25,0.24 10 false Off 2.292,0.677 2.771,0.927 0.479,0.25 10 false on(IG) 5.427,0.125 6.948,0.417 1.521,0.292 10 false Approximately 43 sec. 0.281,0.115 1.781,0.354 1.5,0.24 10 false Normal output pattern:



ii.

Fail-safe deactivation condition

When the pulse sensor is normal, to deactivate fail-safe mode, pull up the power window switch to the auto up position and hold it for at least 1 second to fully close the window from the fully open position. As a result, the auto up/down function will return.




b.

Initialization failure

HINT:

During initialization of the power window regulator motor ECU, when the window position or initialization complete status cannot be properly read from the EEPROM, the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Power switch on (IG) Power switch off
(Key-off operation permitted)
Power switch off
(Key-off operation prohibited)
Manual up (Driver door window) X X -
Manual down (Driver door window) ○ X -
Auto up (Driver door window)
(hold switch at auto up position)
○* X -
Auto up (Driver door window) X X -
Auto down (Driver door window) X X -

HINT:
·

○: Operates

·

X: Operation prohibited

·

*: Operates in manual mode without jam protection



Key-linked and Wireless Transmitter-linked Operation*
Power Window Operation Condition
Power switch on (IG) Power switch off
(Key-off operation permitted)
Power switch off
(Key-off operation prohibited)
Key-linked open and close - X X
Wireless transmitter-linked open - X X

*: This function is set through the customize function, as it is off by default.


HINT:

X: Operation prohibited



i.

Power window regulator master switch LED control

HINT:

During initialization of the power window regulator motor ECU, when the window position or initialization complete status cannot be properly read from the EEPROM during fail-safe mode, the LED illuminates as shown in the illustration.


1.

For driver door:

B274524
4.042,3.573 3.958,3.573 3.958,3.573 3.76,3.104 false 0.719,3.531 1.615,3.917 0.896,0.385 10 false Window lock switch signal: 2.219,3.938 2.448,4.125 0.229,0.188 10 false Off 2.229,3.531 2.458,3.74 0.229,0.208 10 false On 0.719,1.677 1.104,1.927 0.385,0.25 10 false LED: 1.875,2.125 2.458,2.302 0.583,0.177 10 false Turns off 1.885,1.677 2.5,1.885 0.615,0.208 10 false Turns on 0.719,0.656 1.688,0.885 0.969,0.229 10 false Power switch: 2.219,1.177 2.469,1.385 0.25,0.208 10 false Off 2.208,0.667 2.719,0.938 0.51,0.271 10 false on(IG) 0.177,0.146 2.292,0.344 2.115,0.198 10 false Initialization failure output pattern: 4.063,3.49 4.615,3.75 0.552,0.26 10 false 1.5 sec. 2.583,3.146 3.104,3.344 0.521,0.198 10 false 1.5 sec. 2.583,2.792 3.104,2.99 0.521,0.198 10 false 1.0 sec. 2.583,2.427 3.104,2.625 0.521,0.198 10 false 0.5 sec.




c.

LIN communication failure

HINT:

If the LIN communication line malfunctions (communication stop), the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Power switch on (IG)
Manual up ○*
Manual down ○
Auto up (hold switch at auto up position) -
Auto up -
Auto down -

HINT:
·

○: Operates

·

*: Jam protection can operate.




d.

LIN communication failure and pulse sensor failure

HINT:

If the LIN communication line malfunctions (communication stop) and the pulse sensor for the jam protection function has problems, the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Always
Manual up X
Manual down X
Auto up (hold switch at auto up position) X
Auto up X
Auto down X

HINT:
·

X: Operation prohibited

·

When the jam protection function does not operate due to a LIN communication failure, the manual up and auto up functions will not operate.




e.

LIN communication failure and abnormal window position learned value or initialization failure

HINT:

If the LIN communication line malfunctions (communication stop) and the window position or the learned value is abnormal, the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Always
Manual up ○*
Manual down ○
Auto up (hold switch at auto up position) -
Auto up -
Auto down -

HINT:
·

○: Operates

·

*: Jam protection can operate and window reverses upon reaching the fully closed position.