When the power switch is on (IG), the power window regulator motor assembly (for front passenger door) is operated by the power window regulator switch assembly (for front passenger door).
Inspect the fuses for circuits related to this system before performing the following procedure.
Disconnect the power window regulator switch assembly (for front passenger door) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K11-3 (B) - Body ground | Power switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Power Window Regulator Switch Assembly (for Front Passenger Door)) |
Remove the power window regulator switch assembly (for front passenger door).
Click hereVehicle Exterior>WINDOW / GLASS>FRONT PASSENGER SIDE POWER WINDOW SWITCH>REMOVAL
Measure the resistance when the switch is operated according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (D) - 2 (SD) | UP | Below 1 Ω |
| 3 (B) - 4 (U) | Below 1 Ω | |
| 1 (D) - 2 (SD) | off | Below 1 Ω |
| 4 (U) - 5 (SU) | Below 1 Ω | |
| 4 (U) - 5 (SU) | DOWN | Below 1 Ω |
| 1 (D) - 3 (B) | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the power window regulator motor assembly (for front passenger door) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K11-4 (U) - K14-2 (U) | Always | Below 1 Ω |
| K11-1 (D) - K14-1 (D) | Always | Below 1 Ω |
| K11-4 (U) - Body ground | Always | 10 kΩ or higher |
| K11-1 (D) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Power Window Regulator Master Switch Assembly) |
Remove the power window regulator master switch assembly.
Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW MASTER SWITCH>REMOVAL
Measure the resistance when the switch is operated according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6 (B) - 12 (U) | UP | Below 1 Ω |
| 9 (E) - 13 (D) | Below 1 Ω | |
| 9 (E) - 12 (U) | off | Below 1 Ω |
| 9 (E) - 13 (D) | Below 1 Ω | |
| 6 (B) - 13 (D) | DOWN | Below 1 Ω |
| 9 (E) - 12 (U) | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J10-12 (U) - K11-5 (SU) | Always | Below 1 Ω |
| J10-13 (D) - K11-2 (SD) | Always | Below 1 Ω |
| J10-12 (U) - Body ground | Always | 10 kΩ or higher |
| J10-13 (D) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG