Blind spot monitor beam axis inspection
When performing the blind spot monitor beam axis inspection, move the vehicle to a place where the space shown in the illustration can be secured.
Perform this inspection on level ground.
Make sure that there are no metal objects around the vehicle or on the ground.
Unload the vehicle before beginning the inspection.
Confirm that the tire pressure is correct before beginning the inspection.
Do not place an object other than the reflector (such as a large metallic object) in or allow people to enter the inspection area (W 9 m (29.53 ft.) x L 10 m (32.81 ft.) x H 4 m (13.13 ft.)) shown in the illustration.
Check that DTC C1ABB and DTC C1ABC are not output.
Procedure to enter the Test Mode
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the blind spot monitor main switch (warning canceling switch assembly) on.
Turn the intelligent tester on.
Switch the blind spot monitor sensor to Test Mode using the intelligent tester. Enter the following menus: Body / Blind Spot Monitor Master or Blind Spot Monitor Slave / Utility / BSM Master Beam Axis Inspection or BSM Slave Beam Axis Inspection.
| Tester Display |
|---|
| BSM Master Beam Axis Inspection |
| Tester Display |
|---|
| BSM Slave Beam Axis Inspection |
Perform the blind spot monitor beam axis inspection.
Check that the outer rear view mirror indicators are not illuminated.
If an indicator is illuminated, because there is a possibility that the sensors are reacting to metal or other items, move the vehicle to another place.
Place the reflector at position A.
Set the reflector so that its center is 450 mm (1.48 ft.) above the floor.
Enter Test Mode using the intelligent tester. Move the reflector from position A to B as shown in the illustration.
Make sure that the orientation of the reflector is as shown in the illustration.
The acceptable range for sensor installation angle (horizontal direction) that allows the blind spot monitor system to operate correctly is as shown by the shaded areas inside the broken lines in the illustration (the warning areas).
While moving the reflector, make sure that no one or no objects pass between the vehicle and the reflector.
After placing the reflector in the specified position, quickly exit the inspection area and make sure that objects other than the reflector are not in the inspection area and check that the blind spot monitor indicator does not illuminate.
If the indicator illuminates, repeat the same action (i.e. move the reflector from A to B). If the indicator illuminates again, check the blind spot monitor sensor installation condition.
Move the reflector from position B to C as shown in the illustration.
Make sure that the orientation of the reflector is as shown in the illustration.
While moving the reflector, make sure that no one or no objects pass between the vehicle and the reflector.
After placing the reflector in the specified position, quickly exit the inspection area and make sure that objects other than the reflector are not in the inspection area and check that the blind spot monitor indicator illuminates.
If the indicator does not illuminate, repeat the same action (i.e. move the reflector from B to C). If the indicator does not illuminate again, check the blind spot monitor sensor installation condition.
Finish Test Mode.
The Blind Spot Monitor Installation Condition Inspection
Perform this inspection on level ground.
Unload the vehicle before beginning the inspection.
Confirm that the tire pressure is correct before beginning the inspection.
Remove the rear bumper (See page Vehicle Exterior>EXTERIOR PANELS / TRIM>REAR BUMPER>REMOVAL).
Attach a jig similar to the one shown in the illustration to the outward facing surface of the blind spot monitor sensor and check that the blind spot monitor sensor is perpendicular to the floor surface or within the allowable range.
| A | B | |
|---|---|---|
| Blind spot monitor sensor RH | 17mm
(0.66 in.) |
-17mm
(-0.66 in.) |
| Blind spot monitor sensor LH | 8mm
(0.31 in.) |
-26mm
(1.02 in.) |
Allowable ranges A and B are different between the blind spot monitor sensor LH and RH.
Using the sensor installation stud bolt center lines as a reference, check that the stud bolts are as shown in the illustration.
| Dimension | Specified Value |
|---|---|
| y | 26 to 66 mm
(1.03 to 2.59 in.) |