This circuit provides power to operate the blind spot monitor sensor.
Inspect the fuses for circuits related to this system before performing the following procedure.
Disconnect connector O28 from the blind spot monitor sensor RH.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O28-5 (BRB) - Body ground | Power switch on (IG) | 11 to 14 V |
| O28-5 (BRB) - Body ground | Power switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector O28 from the blind spot monitor sensor RH.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O28-1 (BRGD) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector T10 from the blind spot monitor sensor LH.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T10-5 (BLB) - Body ground | Power switch on (IG) | 11 to 14 V |
| T10-5 (BLB) - Body ground | Power switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector T10 from the blind spot monitor sensor LH.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T10-1 (BLGD) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG