Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM2040EQ _58 Vehicle Interior _014730 HEATING / AIR CONDITIONING _0075108 AIR CONDITIONING SYSTEM J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  Blower Motor Circuit  


DESCRIPTION

The blower motor with fan sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower motor with fan sub-assembly speed signals are transmitted in accordance with changes in the duty ratio.

WIRING DIAGRAM

E229256
2.969,0.938 3.063,1.115 0.094,0.177 10 false 3 5.292,0.615 5.469,0.792 0.177,0.177 10 false 22 3.708,1.344 4.031,1.521 0.323,0.177 10 false GND 2.042,1.25 2.344,1.427 0.302,0.177 10 false HTR 0.177,1.021 1.042,1.469 0.865,0.448 10 false from Auxiliary Battery 3.865,0.708 4.052,0.885 0.188,0.177 10 false SI 3.219,1.031 3.417,1.208 0.198,0.177 10 false +B 5.604,0.708 6.271,1.094 0.667,0.385 10 false BLW 5.292,3.26 5.594,3.438 0.302,0.177 10 false I77 5.292,3.427 6.896,3.76 1.604,0.333 10 false Air Conditioning Amplifier Assembly 3.021,1.76 3.302,1.938 0.281,0.177 10 false I76 3.021,1.927 4.448,2.313 1.427,0.385 10 false Blower Motor with Fan Sub-assembly 4.167,0.615 4.26,0.792 0.094,0.177 10 false 2 4.167,1.25 4.26,1.427 0.094,0.177 10 false 1 5.708,1.781 6.5,1.958 0.792,0.177 10 false Duty Control

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the intelligent tester on.


d.

Enter the following menus: Body / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0, Max.: 31 -
Body Electrical > Air Conditioner > Active Test
Tester Display
Blower Motor
50004 121 2
OK:

Blower motor with fan sub-assembly operates and blower motor speed level changes.



Result:
Result Proceed to
OK A
NG (Blower motor with fan sub-assembly does not operate) B
NG (Blower motor with fan sub-assembly operates but does not change speed) C



A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

B

2.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - BODY GROUND)

C

6.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
2.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - BODY GROUND)
a.

Disconnect the I76 blower motor with fan sub-assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I76-1 (GND) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - AUXILIARY BATTERY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - AUXILIARY BATTERY)
a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
I76-3 (+B) - Body ground Power switch off 11 to 14 V



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY)
a.

Disconnect the I77 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I77-22 (BLW) - I76-2 (SI) Always Below 1 Ω
I77-22 (BLW) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

5.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY
a.

Reconnect the I76 blower motor with fan sub-assembly connector.


b.
E221028
1.5,0.552 1.958,0.833 0.458,0.281 0.75,2.583 0.583,2.948 false 1.656,0.615 2.115,0.885 0.458,0.271 10 false I77 0.177,0.156 0.677,0.563 0.5,0.406 10 false *a 0.323,2.979 1.083,3.333 0.76,0.354 10 false BLW
*a Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
I77-22 (BLW) - Body ground Always 4.5 to 5.5 V



Result:
Proceed to
OK
NG



OK

6.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

6.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
a.
E230728
1.354,0.5 1.781,0.76 0.427,0.26 2.031,1.281 1.865,1.781 false 1.469,0.563 1.75,0.719 0.281,0.156 10 false I77 1.708,1.813 2.073,1.979 0.365,0.167 10 false BLW 2.76,4 3.104,4.167 0.344,0.167 10 false GND 0.219,0.167 0.448,0.313 0.229,0.146 10 false *a
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Remove the air conditioning amplifier assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL


b.

Reconnect the I77 air conditioning amplifier assembly connector.


c.

Turn the power switch on (IG).


d.

Turn the blower switch on (LO).


e.

Measure the waveform between terminal I77-22 (BLW) of the air conditioning amplifier assembly and body ground.

OK:

Waveform is similar to that shown in the illustration.


HINT:

The waveform varies with the blower speed.


Item Content
Tool setting 1 V/DIV., 500 μs/DIV.
Vehicle condition Power switch on (IG)
Blower switch on (LO)


Result:
Proceed to
OK
NG



OK

REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY