Home › Steering › POWER ASSIST SYSTEMS › POWER STEERING SYSTEM › from 2015.04
RM2040EQ _55 Steering _014713 POWER ASSIST SYSTEMS _0074999 POWER STEERING SYSTEM U

POWER ASSIST SYSTEMS  POWER STEERING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


HINT:

Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Turn the power switch off.


b.

Connect the intelligent tester to the DLC3.


c.

Turn the power switch on (IG).


d.

Turn the intelligent tester on.


e.

Enter the following menus: Chassis / EMPS / Data List.


f.

According to the display on the intelligent tester, read the Data List.

Chassis > EMPS > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Meter Vehicle Velocity Vehicle speed from meter Min.: 0.0 km/h (0.0 mph)
Max.: 300.0 km/h (186.4 mph)
·

Power switch on (READY) and vehicle stopped: 0 km/h (0 mph)

·

Power switch on (READY) and vehicle driven at a constant speed: No significant fluctuation


-
Motor Actual Current Amount of current to motor Min.: -327.68 A
Max.: 327.67 A
Power switch on (READY) and steering wheel being turned: The value rises -
Command Value Current Requested current to motor Min.: -327.68 A
Max.: 327.67 A
Power switch on (READY) and steering wheel being turned: Value changes in proportion to steering effort
-The value increases when turning left and decreases when turning right
-
Steering Angle Velocity Steering angle speed Min.: -32768 deg/s
Max.: 32767 deg/s
Power switch on (READY) and steering wheel being turned: Value changes in proportion to steering speed
-The value increases when turning left and decreases when turning right
-
Thermistor Temperature ECU substrate temperature Min.: -40.0°C (-40.0°F)
Max.: 150.0°C (302.0°F)
Power switch on (READY): -40°C to 150°C (-40°F to 302°F) -
PIG Power Supply Power source voltage to active motor Min.: 0.0000 V
Max.: 20.1531 V
Power switch on (READY) and steering wheel being turned: 9 to 16 V -
IG Power Supply IG power source voltage Min.: 0.0000 V
Max.: 20.1531 V
Power switch on (IG): 9 to 16 V -
Steering Wheel Torque Steering wheel torque Min.: -327.68 Nm
Max.: 7.00 Nm
Power switch on (READY) and steering wheel being turned: Value changes in proportion to steering effort
-The value increases when turning left and decreases when turning right
-
Motor Rotation Angle Motor rotation angle Min.: 0.000 deg
Max.: 1441.770 deg
Power switch on (READY) and steering wheel being turned: During steering operation, motor rotation angle value changes from 0 to 360° -
Motor Voltage Motor power supply voltage Min.: 0.000 V
Max.: 98.000 V
Power switch on (READY) and steering wheel being turned: 9 to 16 V -
Motor Terminal Volt(U) Motor terminal voltage (A phase) Min.: 0.000 V
Max.: 98.000 V
Power switch on (READY) and steering wheel being turned: Value changes within 4 to 35 V range -
Motor Terminal Volt(V) Motor terminal voltage (B phase) Min.: 0.000 V
Max.: 98.000 V
Power switch on (READY) and steering wheel being turned: Value changes within 4 to 35 V range -
Motor Terminal Volt(W) Motor terminal voltage (C phase) Min.: 0.000 V
Max.: 98.000 V
Power switch on (READY) and steering wheel being turned: Value changes within 4 to 35 V range -
Torque Sensor 1 Output Torque sensor voltage Min.: 0.0000 V
Max.: 4.9725 V
·

Power switch on (READY) and steering wheel not being turned (without load): 2.3 to 2.7 V

·

Power switch on (READY) and steering wheel being turned to the right with vehicle stopped: 2.5 to 4.7 V

·

Power switch on (READY) and steering wheel being turned to the left with vehicle stopped: 0.3 to 2.5 V


-
Torque Sensor 2 Output Torque sensor voltage Min.: 0.0000 V
Max.: 4.9725 V
·

Power switch on (READY) and steering wheel not being turned (without load): 2.3 to 2.7 V

·

Power switch on (READY) and steering wheel being turned to the right with vehicle stopped: 0.3 to 2.5 V

·

Power switch on (READY) and steering wheel being turned to the left with vehicle stopped: 2.5 to 4.7 V


-
IG ON/OFF Times Number of times of power switch ON/OFF after fail detection Min.: 0 times
Max.: 65535 times
- This value indicates the number of times of power switch ON/OFF after the latest DTC detection.
Motor Overheat Record Continuous overheat prevention control record Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Motor Lo Power Record PIG power source voltage drop record Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Eng Rev Inter Record Record of engine speed signal interruption Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Spd Sig Invalid Record Record of vehicle speed signal invalid Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Battery Voltage Lo Record Auxiliary battery voltage reduction history Min.: 0 times
Max.: 65535 times
0 to 65535 -
Battery Voltage Auxiliary battery voltage Min.: 0.0 V
Max.: 25.5 V
Power switch on (IG): 9 to 16 V -
PS Assist Signal Power steering assist signal ON or OFF
·

OFF: Power switch on (IG)

·

ON: Power switch on (READY)


-
Ready Status Ready status Ready or OFF Ready or OFF -
Motor Overheat Limit Cnt(Normal) Number of times that assist limit was performed according to the estimated temperature of the portion where heat was generated in the power steering ECU assembly and motor coil Min.: 0 times
Max.: 255 times
- -
Assist Limit Cnt(Power Voltage Low) Number of times that assist limit was performed due to battery voltage having dropped to 9 V or below Min.: 0 times
Max.: 255 times
- -
Power Vol Low Prevention Limit Cnt Number of times that assist limit was performed due to battery voltage having dropped to 9.7 V or below Min.: 0 times
Max.: 255 times
- -
Eng Stall/Ready OFF Cnt Number of times that assist limit was performed after the engine stalled and the power switch was turned off Min.: 0 times
Max.: 255 times
- -
Motor Overheat Limit Cnt(Motor Overload) Number of times that assist limit was performed to prevent the system from overheating in a case where the motor is overloaded because it is locked due to the steering wheel being turned to the full lock position or a tire hitting a curb Min.: 0 times
Max.: 255 times
- -
DCDC Current Limit Cnt(DCDC Malf) Number of times that the power steering ECU has limited the current to the power steering motor while the DC/DC converter is malfunctioning. Min.: 0 times
Max.: 255 times
- -
Assist Limit Cnt(Vehicle Spd Sig Malf) Number of times that assist power was set to a value suitable for high-speed driving when high speed is detected due to an abnormal vehicle speed signal Min.: 0 times
Max.: 255 times
- -
Battery Voltage Keep Limit Cnt Number of times that the system was limited to conserve battery voltage Min.: 0 times
Max.: 255 times
- -
Assist Limit Record 1 Information of assist limit that was used in the past or is currently in use (latest history) Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, Vhcl Spd Sig Malf, Batt Vol Keep - -
Record 1 Key Cycle Number of times that the power switch was turned on (IG) before Assist Limit Record 1 was stored Min.: 0 times
Max.: 65535 times
- -
Record 1 Key Cycle Elapsed Time Period of time that elapsed since the power switch was turned on (IG) before Assist Limit Record 1 was stored Min.: 0.0 s
Max.: 53687091.1 s
- -
Assist Limit Record 2 Information of assist limit that was used in the past (second latest history) Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, Vhcl Spd Sig Malf, Batt Vol Keep - -
Record 2 Key Cycle Number of times that the power switch was turned on (IG) after Assist Limit Record 2 was stored before Assist Limit Record 1 was stored Min.: 0 times
Max.: 65535 times
- -
Record 2 Key Cycle Elapsed Time Period of time that elapsed since the power switch was turned on (IG) before Assist Limit Record 2 was stored Min.: 0.0 s
Max.: 53687091.1 s
- -
Assist Limit Record 3 Information of assist limit that was used in the past (third latest history) Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, Vhcl Spd Sig Malf, Batt Vol Keep - -
Record 3 Key Cycle Number of times that the power switch was turned on (IG) after Assist Limit Record 3 was stored before Assist Limit Record 2 was stored Min.: 0 times
Max.: 65535 times
- -
Record 3 Key Cycle Elapsed Time Period of time that elapsed since the power switch was turned on (IG) before Assist Limit Record 3 was stored Min.: 0.0 s
Max.: 53687091.1 s
- -
Current Key Cycle Number of times that power switch was turned on (IG) Min.: 0 times
Max.: 65535 times
- -
Current Key Cycle Elapsed Time Time elapsed since power switch was turned on (IG) Min.: 0.0 s
Max.: 53687091.1 s
- -
The Number of DTCs Number of detected DTCs when freeze frame data stored Min.: 0
Max.: 255
0 to 255 -