Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2015.04
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A09-265  DC / DC Converter Status Circuit Low Input  


DESCRIPTION

Refer to the description for DTC P0A08-264 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A08-264).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A09-265 DC / DC Converter Status Circuit Low Input Open or GND short in NODD signal circuit of DC/DC converter
·

Wire harness or connector

·

Inverter with converter assembly

·

Power management control ECU


Does not come on Master Warning Light:
Comes on

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A08-264 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A08-264).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page1Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

OK

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

NG

CONNECT SECURELY

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

OK

3.CHECK POWER MANAGEMENT CONTROL ECU (NODD)

NG

CONNECT SECURELY

3.CHECK POWER MANAGEMENT CONTROL ECU (NODD)
a.

Turn the power switch on (READY).


b.
A259789C74
0.573,0.948 0.99,1.188 0.417,0.24 1.833,0.958 2.25,1.198 0.417,0.24 0.781,1.844 1,2.583 false 1.823,1.698 2.083,2.563 false 0.198,0.146 0.51,0.375 0.313,0.229 10 false *a 0.667,1 1.073,1.26 0.406,0.26 10 false A38 0.854,2.625 1.625,2.969 0.771,0.344 10 false NODD 2.01,1.01 2.344,1.271 0.333,0.26 10 false I3 2.104,2.594 2.438,2.792 0.333,0.198 10 false E1
*a Component with harness connected
(Power Management Control ECU)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A38-23 (NODD) - I3-6 (E1) Power switch on (READY) 5 to 7 V



c.

Turn the power switch off.

Result:
Proceed to
OK
NG




OK

4.CLEAR DTC

NG

7.CHECK HARNESS AND CONNECTOR (RESISTANCE VALUE OF NODD INSIDE POWER MANAGEMENT CONTROL ECU)
4.CLEAR DTC
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Clear DTCs and freeze frame data.

Powertrain > Hybrid Control > Clear DTCs
50002 236

e.

Turn the power switch off.

Result:
Proceed to
NEXT




NEXT

5.CHECK DTC OUTPUT (HYBRID CONTROL)
5.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (READY).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
P0A09-265 is not output. A
P0A09-265 is output again. B



e.

Turn the power switch off.



A

6.CHECK FOR INTERMITTENT PROBLEMS

B

6.CHECK FOR INTERMITTENT PROBLEMS

OK

NG

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA

7.CHECK HARNESS AND CONNECTOR (RESISTANCE VALUE OF NODD INSIDE POWER MANAGEMENT CONTROL ECU)

OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

8.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)
8.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A13 from the inverter with converter assembly.


c.

Disconnect connector A38 from the power management control ECU.


d.
A259909C34
1.542,0.313 1.958,0.552 0.417,0.24 1.302,3.813 1.719,4.052 0.417,0.24 1.49,1.333 0.948,1.583 false 0.906,3.979 1.219,4.344 false 0.177,0.156 0.51,0.406 0.333,0.25 10 false *a 0.583,1.531 1.073,1.76 0.49,0.229 10 false NODD 0.177,2.219 0.448,2.417 0.271,0.198 10 false *b 1.083,4.375 1.521,4.573 0.438,0.198 10 false NODD 1.615,0.354 1.99,0.625 0.375,0.271 10 false A13 1.385,3.844 1.813,4.135 0.427,0.292 10 false A38
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Rear view of wire harness connector
(to Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A13-5 (NODD) - A38-23 (NODD) Power switch off Below 1 Ω
A13-5 (NODD) or A38-23 (NODD) - Body ground and other terminals Power switch off 10 kΩ or higher



e.

Connect the inverter with converter assembly connector.


f.

Connect the power management control ECU connector.

Result:
Proceed to
OK
NG




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR