When the power management control ECU detects that a safety device is operated, it will prohibit hybrid system operation or shut off the system main relay. The 5 safety devices are located as follows; 1 in the service plug grip, and at the inverter with converter assembly, there is 1 on the connector cover assembly for the air conditioning fuse, 1 on the upper inverter cover for the terminals of the motor cable, 1 on the upper inverter cover for the terminals of the generator cable and 1 in the No. 4 engine wire (air conditioning harness). If the service plug grip, connector cover assembly, upper inverter cover, or No. 4 engine wire (air conditioning harness) is removed, the interlock signal line will be open. If the vehicle is being driven, this condition will be determined to be an open circuit and the system main relays will not be shut off. If the safety devices are re-installed correctly, the system will return to normal when the power switch is turned on (IG).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A0D-350 | High Voltage System Inter-Lock Circuit High | Operating any of the safety devices with the vehicle stopped (ILK signal is ON) and turning the power switch on (IG) | ·
Wire harness or connector ·
Power management control ECU ·
Service plug grip ·
Inverter with converter assembly ·
No. 4 engine wire ·
Upper inverter cover |
Does not come on | Master Warning Light:
Comes on |
| P0A0D-351 | High Voltage System Inter-Lock Circuit High | Interlock signal line opens (ILK signal is ON) while the vehicle is being driven | ·
Wire harness or connector ·
Power management control ECU ·
Service plug grip ·
Inverter with converter assembly ·
No. 4 engine wire ·
Upper inverter cover |
Does not come on | Master Warning Light:
Comes on |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A0D only is output. | A |
| P0A1D is output | B |
Turn the power switch off.
A
B
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the power switch off.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A0D-350 or P0A0D-351 is output again. | A |
| Neither P0A0D-350 or P0A0D-351 is output again. | B |
Turn the power switch off.
A
B
Be sure to wear insulated gloves.
Check if the service plug grip is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
For the removal and installation procedures (Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>SERVICE PLUG GRIP>COMPONENTS).
P0A0D-350 is also set if the power switch is turned on (IG) with the service plug grip removed. Confirm the conditions when the malfunction occurred.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check if the upper inverter cover (generator cable side) of the inverter with converter assembly is installed correctly.
The upper inverter cover (generator cable side) is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check if the upper inverter cover (motor cable side) of the inverter with converter assembly is installed correctly.
The upper inverter cover (motor cable side) is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check if the connector cover assembly of the inverter with converter assembly is installed correctly.
The connector cover assembly is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check if the No. 4 engine wire (air conditioning harness) is connected correctly.
The No. 4 engine wire (air conditioning harness) connector is connected correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A14 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A14-16 (ILKI) - Body ground | Power switch on (IG) | 11 to 14 V |
Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A14 from the inverter with converter assembly.
| *a | Component without harness connected
(Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A14-16 (ILKI) - A14-5 (ILKO) | Power switch off | Less than 10 Ω |
Do not remove the upper inverter cover, connector cover assembly and No. 4 engine wire.
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A14 from the inverter with converter assembly.
Install the service plug grip.
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A14-5 (ILKO) - Body ground | Power switch off | Below 1 Ω |
Remove the service plug grip.
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the connections of each connector.
Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A14 from the inverter with converter assembly.
Disconnect connector A38 from the power management control ECU.
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector
(to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A14-16 (ILKI) - A38-22 (ILK) | Power switch off | Below 1 Ω |
Connect the power management control ECU connector.
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.
| *1 | Upper Inverter Cover (Generator Cable Side) |
Check the condition of the upper inverter cover (generator cable side) interlock.
Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.
Install the upper inverter cover (generator cable side) to the inverter with converter assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper inverter cover (motor cable side) from the inverter with converter assembly.
| *1 | Upper Inverter Cover (Motor Cable Side) |
Check the condition of the upper inverter cover (motor cable side) interlock.
Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.
Install the upper inverter cover (motor cable side) to the inverter with converter assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the connector cover assembly from the inverter with converter assembly.
| *1 | Connector Cover Assembly |
Check the condition of the connector cover assembly interlock.
Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.
The connector cover assembly is not available separately. If it requires replacement, replace the inverter with converter assembly.
Install the connector cover assembly to the inverter with converter assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the No. 4 engine wire (air conditioning harness) from the inverter with converter assembly.
| *1 | No. 4 engine wire (air conditioning harness) |
Check the No. 4 engine wire (air conditioning harness) interlock.
Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.
Connect the No. 4 engine wire (air conditioning harness) to the inverter with converter assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the service plug grip.
| *1 | Service Plug Grip |
Check the condition of the service plug grip interlock.
Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.
Install the service plug grip.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *1 | Interlock Connector |
Check that the interlock connector at the service plug grip installation socket is connected correctly.
The connector is connected correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A14 from the inverter with converter assembly.
Disconnect connector r2 from the service plug grip.
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector
(to Service Plug Grip) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A14-5 (ILKO) - r2-1(ILK) | Power switch off | Below 1 Ω |
Connect the service plug grip connector.
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG