Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2016.05
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0343-747  Camshaft Position Sensor "A" Circuit High Input  


DESCRIPTION

Refer to the description for DTC P0340-886 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0340-886).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0343-747 Camshaft Position Sensor "A" Circuit High Input GI signal is not input for 2 sec. or more while the engine is running.
·

SFI system

·

Inverter with converter assembly

·

ECM

·

Power management control ECU

·

Wire harness or connector


Does not come on Master Warning Light:
Comes on

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0340-886 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0340-886).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page1 Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK DTC OUTPUT (ENGINE AND ECT)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Engine and ECT/ DTC.

Powertrain > Engine and ECT > Trouble Codes
50001 234

d.

Check if DTCs are output.

Result:
Result Proceed to
SFI system DTCs are not output. A
Any of the following DTCs are output. B


DTC No. Relevant Diagnosis
P0340 Camshaft Position Sensor Circuit Malfunction
P0342 Camshaft Position Sensor "A" Circuit Low Input (Bank 1 or Single Sensor)
P0343 Camshaft Position Sensor "A" Circuit High Input (Bank 1 or Single Sensor)


e.

Turn the power switch off.



A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
None of the following DTCs are output. A
Any of the following DTCs are output. B


DTC No. Relevant Diagnosis
P06B0-163 Sensor Power Supply "A" Circuit / Open
P06D6-511 Sensor Reference Voltage "F" Circuit / Open
P06E6-164 Sensor Power Supply "C" Circuit / Open
P0A1B-198, 786, 794 Drive Motor "A" Control Module
P1C2B-192 Drive Motor "A" A/D Converter Circuit
P1C73-512 Sensor Standard Voltage "F" Circuit / Open
P1CA7-193 Drive Motor Control Module Malfunction
P1CAD-168 Drive Motor "A" Position Sensor Angle Malfunction
P1CB0-795 Drive Motor "A" Position Sensor REF Signal Cycle Malfunction
P1CB3-796 Drive Motor "A" Position Sensor REF Signal Stop Malfunction
P3134-661 Communication Error from Drive Motor "A" to Generator

HINT:
·

P0343-747 may be set due to a malfunction which also causes the DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.




e.

Turn the power switch off.



A

3.CHECK DTC OUTPUT (HYBRID CONTROL)

B

3.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
P0340-886 is not output. A
P0340-886 is also output. B



e.

Turn the power switch off.



A

4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

7.CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)
4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

NOTICE:

Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.


A258444N02
5.792,1.427 6.125,1.625 0.333,0.198 2.448,1.635 2.781,1.833 0.333,0.198 1.677,1.948 2.01,2.146 0.333,0.198 5.823,1.438 6.094,1.604 0.271,0.167 10 true A13 2.5,1.646 2.771,1.813 0.271,0.167 10 true E1 1.708,1.969 1.979,2.135 0.271,0.167 10 true A14

OK:

The connectors are connected securely and there are no contact pressure problems.


HINT:

When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


Result:
Proceed to
OK
NG




OK

5.CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)

NG

CONNECT SECURELY

5.CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)

OK

6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)

NG

CONNECT SECURELY

6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the connector A14 from the inverter with converter assembly.


c.

Disconnect connector A25 from the ECM.


d.

Disconnect connector A38 from the power management control ECU.


e.

Connect the cable to the negative (-) auxiliary battery terminal.


f.

Turn the power switch on (IG).


g.
A284452C02
1.521,1.76 1.927,2.042 0.406,0.281 1.51,4.302 1.917,4.583 0.406,0.281 2.323,3.854 2.906,4.104 false 1.198,0.385 1.208,0.948 false 1.594,4.385 2.052,4.583 0.458,0.198 10 false A25 0.271,2.469 0.729,2.667 0.458,0.198 10 false *b 1.615,1.833 2.073,2.031 0.458,0.198 10 false A14 0.24,0.24 0.698,0.438 0.458,0.198 10 false *a 2.969,4.042 3.427,4.24 0.458,0.198 10 false G2O 1.125,0.219 1.583,0.417 0.458,0.198 10 false GI
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Front view of wire harness connector
(to ECM)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A14-1 (GI) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector and ECM connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



h.

Turn the power switch off.


i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
A14-1 (GI) - A25-60 (G2O) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Switch Condition Specified Condition
A14-1 (GI) or A25-60 (G2O) - Body ground and other terminals Power switch off 10 kΩ or higher



j.

Disconnect the cable from the negative (-) auxiliary battery terminal.


k.

Connect the power management control ECU connector.


l.

Connect the ECM connector.


m.

Connect the inverter with converter assembly connector.

Result:
Proceed to
OK
NG




OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)

OK

8.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)

NG

CONNECT SECURELY

8.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the connector A14 from the inverter with converter assembly.


c.

Disconnect connector A25 from the ECM.


d.

Disconnect connector A38 from the power management control ECU.


e.
A284452C02
1.521,1.76 1.927,2.042 0.406,0.281 1.51,4.302 1.917,4.583 0.406,0.281 2.323,3.854 2.906,4.104 false 1.198,0.385 1.208,0.948 false 1.594,4.385 2.052,4.583 0.458,0.198 10 false A25 0.271,2.469 0.729,2.667 0.458,0.198 10 false *b 1.615,1.833 2.073,2.031 0.458,0.198 10 false A14 0.24,0.24 0.698,0.438 0.458,0.198 10 false *a 2.969,4.042 3.427,4.24 0.458,0.198 10 false G2O 1.125,0.219 1.583,0.417 0.458,0.198 10 false GI
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Front view of wire harness connector
(to ECM)


Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
A14-1 (GI) - A25-60 (G2O) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Switch Condition Specified Condition
A14-1 (GI) or A25-60 (G2O) - Body ground and other terminals Power switch off 10 kΩ or higher



f.

Connect the power management control ECU connector.


g.

Connect the ECM connector.


h.

Connect the inverter with converter assembly connector.

Result:
Proceed to
OK
NG




OK

9.CHECK HARNESS AND CONNECTOR (ECM - POWER MANAGEMENT CONTROL ECU)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

9.CHECK HARNESS AND CONNECTOR (ECM - POWER MANAGEMENT CONTROL ECU)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A25 from the ECM.


c.

Disconnect connector A38 from the power management control ECU.


d.

Disconnect the connector A14 from the inverter with converter assembly.


e.
A259781C12
0.208,1.177 0.625,1.417 0.417,0.24 1.313,3.771 1.729,4.01 0.417,0.24 2.354,1.635 2.854,2.052 false 1.042,3.979 1.271,4.333 false 0.146,0.083 0.51,0.448 0.365,0.365 10 false *a 2.74,2.083 3.219,2.333 0.479,0.25 10 false G2O 0.302,1.229 0.771,1.542 0.469,0.313 10 false A25 0.146,2.25 0.521,2.531 0.375,0.281 10 false *b 1.417,3.823 2.01,4.198 0.594,0.375 10 false A38 1.26,4.354 1.698,4.656 0.438,0.302 10 false GI
*a Front view of wire harness connector
(to ECM)
*b Rear view of wire harness connector
(to Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
A25-60 (G2O) - A38-19 (GI) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Switch Condition Specified Condition
A25-60 (G2O) or A38-19 (GI) - Body ground and other terminals Power switch off 10 kΩ or higher



f.

Connect the inverter with converter assembly connector.


g.

Connect the power management control ECU connector.


h.

Connect the ECM connector.

Result:
Proceed to
OK
NG




OK

10.CHECK INVERTER WITH CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.CHECK INVERTER WITH CONVERTER ASSEMBLY

OK

11.CHECK POWER MANAGEMENT CONTROL ECU

NG

REPLACE INVERTER WITH CONVERTER ASSEMBLY

11.CHECK POWER MANAGEMENT CONTROL ECU

OK

NG