The MG ECU located in the inverter with converter assembly monitors its internal operation and it will set DTCs when it detects malfunctions. If any of the following DTCs are output, replace the inverter with converter assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P06B0-163 | Sensor Power Supply "A" Circuit / Open | IPM positive power source error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P06D6-511 | Sensor Reference Voltage "F" Circuit / Open | Standard voltage for analog signal offset | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P06E6-164 | Sensor Power Supply "C" Circuit / Open | IPM negative power source error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A1A-151 | Generator Control Module | Run pulse signal cycle deviation or stop | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A1A-166 | Generator Control Module | R/D converter NM stop error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A1A-658 | Generator Control Module | ALU error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A1A-791 | Generator Control Module | R/D converter communication error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A1B-198 | Drive Motor "A" Control Module | R/D converter NM stop error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A1B-786 | Drive Motor "A" Control Module | ALU error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P0A1B-794 | Drive Motor "A" Control Module | R/D converter communication error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P1C2A-155 | Generator A/D Converter Circuit | A/D converter error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit | A/D converter error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P1C73-512 | Sensor Standard Voltage "F" Circuit / Open | Standard voltage for analog signal offset | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P1CA6-156 | Generator Control Module Malfunction | CPU ROM-RAM error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P1CA7-193 | Drive Motor Control Module Malfunction | CPU ROM-RAM error | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P3133-659 | Communication Error from Generator to Drive Motor "A" | Communication error (from MG1 to MG2) | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
| P3134-661 | Communication Error from Drive Motor "A" to Generator | Communication error (from MG2 to MG1) | Inverter with converter assembly | Comes on | Master Warning Light:
Comes on |
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>COMPONENTS)
| Proceed to |
|---|
| NEXT |
NEXT