HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P06B0-163  Sensor Power Supply "A" Circuit / Open  P06D6-511  Sensor Reference Voltage "F" Circuit / Open  P06E6-164  Sensor Power Supply "C" Circuit / Open  P0A1A-151  Generator Control Module  P0A1A-166  Generator Control Module  P0A1A-658  Generator Control Module  P0A1A-791  Generator Control Module  P0A1B-198  Drive Motor "A" Control Module  P0A1B-786  Drive Motor "A" Control Module  P0A1B-794  Drive Motor "A" Control Module  P1C2A-155  Generator A/D Converter Circuit  P1C2B-192  Drive Motor "A" A/D Converter Circuit  P1C73-512  Sensor Standard Voltage "F" Circuit / Open  P1CA6-156  Generator Control Module Malfunction  P1CA7-193  Drive Motor Control Module Malfunction  P3133-659  Communication Error from Generator to Drive Motor "A"  P3134-661  Communication Error from Drive Motor "A" to Generator  


DESCRIPTION

The MG ECU located in the inverter with converter assembly monitors its internal operation and it will set DTCs when it detects malfunctions. If any of the following DTCs are output, replace the inverter with converter assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P06B0-163 Sensor Power Supply "A" Circuit / Open IPM positive power source error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P06D6-511 Sensor Reference Voltage "F" Circuit / Open Standard voltage for analog signal offset Inverter with converter assembly Comes on Master Warning Light:
Comes on
P06E6-164 Sensor Power Supply "C" Circuit / Open IPM negative power source error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1A-151 Generator Control Module Run pulse signal cycle deviation or stop Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1A-166 Generator Control Module R/D converter NM stop error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1A-658 Generator Control Module ALU error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1A-791 Generator Control Module R/D converter communication error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-198 Drive Motor "A" Control Module R/D converter NM stop error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-786 Drive Motor "A" Control Module ALU error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0A1B-794 Drive Motor "A" Control Module R/D converter communication error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1C2A-155 Generator A/D Converter Circuit A/D converter error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1C2B-192 Drive Motor "A" A/D Converter Circuit A/D converter error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1C73-512 Sensor Standard Voltage "F" Circuit / Open Standard voltage for analog signal offset Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1CA6-156 Generator Control Module Malfunction CPU ROM-RAM error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1CA7-193 Drive Motor Control Module Malfunction CPU ROM-RAM error Inverter with converter assembly Comes on Master Warning Light:
Comes on
P3133-659 Communication Error from Generator to Drive Motor "A" Communication error (from MG1 to MG2) Inverter with converter assembly Comes on Master Warning Light:
Comes on
P3134-661 Communication Error from Drive Motor "A" to Generator Communication error (from MG2 to MG1) Inverter with converter assembly Comes on Master Warning Light:
Comes on

PROCEDURE

1.REPLACE INVERTER WITH CONVERTER ASSEMBLY

NEXT

COMPLETED