This circuit sends a charging suspension signal from the certification ECU (smart key ECU assembly) to the mobile wireless charger cradle assembly. Based on this signal, the mobile wireless charger cradle assembly suspends or resumes wireless charging.
The wireless charging system uses the same radio wave frequency that is used to perform verification of the electrical key transmitter sub-assembly. Therefore, when the electrical key transmitter sub-assembly verification is being performed, the certification ECU (smart key ECU assembly) sends a charging suspension signal to the wireless charging system to suspend charging.
Before replacing the certification ECU (smart key ECU assembly), refer to Service Bulletin.
| *a | Component with harness connected
(Mobile Wireless Charger Cradle Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
*1: When the power switch is turned from off to on (ACC), the mobile wireless charger cradle assembly monitors the charging suspension signal for 5 seconds. If the charging suspension signal is not 4 V or more for 0.8 seconds or more during monitoring, the mobile wireless charger cradle assembly determines that there is an open in the charging suspension signal line, blinks (pattern 1) the indicator light (amber), and prohibits operation until the power switch is turned from off to on (ACC) again. *2: For details about conditions when the certification ECU (smart key ECU assembly) sends the charging suspension signal, refer to System Description. |
||
| I183-7 (DIS) - Body ground | For 5 seconds after turning power switch from off to on (ACC)*1 | 4.5 to 6.0 V |
| Device being charged | Below 1 V | |
| Charging suspended due to smart entry and start system status*2 | 4.5 to 6.0 V | |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I183 mobile wireless charger cradle assembly connector.
Disconnect the O2 certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I183-7 (DIS) - O2-16 (ASEL) | Always | Below 1 Ω |
| I183-7 (DIS) or O2-16 (ASEL) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG