CAN COMMUNICATION SYSTEM > GENERAL



OUTLINE
  1. The Controller Area Network (CAN) uses V bus and sub bus 15.

  2. The CAN V bus and CAN sub bus 15 are HS-CAN buses that operate at 500 kbps.

  3. Each CAN bus has 2 terminating resistors which are necessary for accurate judgment of communication.

  4. The terminating resistors for each bus are located as shown in the following table.

    Speed Communication
    Bus
    Terminating Resistor Location
    High-speed (HS-CAN)
    CAN V Bus
    1. ECM
    2. Combination Meter Assembly
    CAN Sub Bus 15
    1. ECM
    2. Power Management Control ECU

  5. The power management control ECU has a gateway function and is used to transmit data between the CAN V bus and the CAN sub bus 15.


MAJOR DIFFERENCE
  1. The new models have been modified from the previous models as shown below:

    1. The separate type yawrate sensor has been discontinued.